Synectic SY057 User Manual

SY057
Encoder Splitter
User Manual
Rev. 3 14th October 2014
SY057 provides a convenient way of splitting a master encoder signal across multiple drives or motion controllers. Its compact design and technical features makes it a perfect solution for sending material encoder solutions to more than one device.
The encoder input is switch selectable for operation with either standard RS485/RS422 with differential TTL or HTL signals, Differential voltage or single ended pulse.
SY057 unit as shipped
Special features
SY057 Expands the output from one shaft encoder to 4,8,12 or 16 individually
isolated encoder signals.
SY057 doesn’t require direct electrical connection between the input and any of the
output encoder groups.
Every encoder group of signals can operate on a separate power supply SY057 reduces the noise in the output signal due to the absence of long cable runs. Plug in Screw terminal wiring Piano style DIL configuration switches
The following figure shows a block diagram explaining the principle of operation and the potential conditions between the circuits
SY057 Block Diagram
Location of Frequency divider & Input configuration switches
Encoder output connectors
Divider’s Switch Settings
The Divider functionality is available on channels 3 and 4. The following diagrams show how to set the divider’s functionality switches.
Divider = 1
Divider = 2
Divider = 4
Divider = 8
Divider = 16
Divider = 32
Divider = 64
Divider = 128
SW1 SW2 SW3 Division
ON ON ON 1 ON ON OFF 2 ON OFF ON 4
ON OFF OFF 8 OFF ON ON 16 OFF ON OFF 32 OFF OFF ON 64 OFF OFF OFF 128
Input Configuration switches
The following diagrams show how to set the input signal’s type.
N.B: On is
Input Signal Type Input
Switches
A B Z
SW1 SW2 SW3 SW4 SW5 SW6
Single ended pulse Off On Off On Off On Differential Output Off Off Off Off Off Off RS485 / RS422 On Off On Off On Off
Encoder Excitation Input Switches
SW7 SW8
External 5 – 30 V Supply Off Off SY057 5V Supply On On
RS485/RS422 input with external 5 – 30V encoder excitation.
Single ended pulse input with SY057 5V encoder excitation.
Differential input with external 5 – 30V encoder excitation.
Technical Specifications
Feature Specification
Power Supply 9 – 30 Vdc
Number of Impulse Inputs 1 in for each 4 out OR
1 in for multiples of 4 out
Galvanic Isolation Yes
Input types Differential Yes
Max frequency; TTL, HTL 500 KHz
Input type single ended signals with
TTL levels
Yes
Divide feature On Channels 3 and 4; Divide by: 1, 2, 4,
8, 16, 32, 64 or 128
Set up selection DIL switches on top under hinged did
Expandable In banks of 4
Case din rail modular PC / ABS
Connection type Plug in terminals
Propagation delay 400 Nano-second
Cascading several units
The number of outputs from the SY057 can be increased in blocks of 4, up to 32, by adding 4 channel expansion modules to the master unit. The expansion modules can be identified as having no power in or input encoder connections. They link to the master unit via 5way expansion links provided with each expansion module.