3C
How To Control The Unit
This fixture is designed to operate as a stand-alone unit or master/slave link. By linking
the units in master/slave connection, the first unit will control the other units to give an
automatic sound activated synchronized light show. This function is good when you
want an instant show. Just plug in and play for immediate operation. You will know
which unit is the master because its yellow LED will light and, the other units (slaves)
LED will no light. It will turn off the laser diode automatically when the music stops after
7 seconds or no signal input.
1. Power switch : Turn on/off the unit.
2. Power cord : This connection supplies main power to the fixture. Be sure the main
power matches the required power of your fixture.
3. Fuseholder : This housing stores the protective fuse. Always replace with the extra
same type fuse. Replacement with anything other than the specified part may
damage your unit.
4. Red LED : Showing the laser diode on/off. When the LED is light. The laser diode is
working.
5. Yellow LED : Showing the Master mode. When the LED is light. It is in master
mode.
6. Mode : Select the master/slaver mode. When you press the button, the yellow LED
will light, it is in master mode. If not, it is in slaver mode. The yellow LED will no light.
7. Signal input/output : uses a φ3.5mm stereo microphone cable to link the unit
together for master/slave link.
8. Remote controller input : uses a 1/4" microphone jack connected to the first unit.
When you press the button, you will find that the remote controller on the first unit will
controls all the other linked units for stand by, and switch off the laser diode.
CAUTION : Use of controls or adjustments or performance of procedures other
than as specified herein may result in hazardous radiation exposure.
Troubleshooting
• If the unit is not functional – check main power supply is ‘on’ and check fuses.
• If the unit is not moving to the music check the sound-activation adjustment (when
applicable)
• If after trying this solution you still have a problem contact your dealer about
authorized technical assistance.
Caution
• Do not obstruct the air vents.
• Do not touch unit while hot.
• No user serviceable parts inside please refer to the nearest authorized technical
assistance office for service.
Power Connections
The unit is supplied with a power plug appropriate to its voltage and destination.
Should any other connections be required they must be carried out with the following
configuration.
Earth = Green/Yellow cable
Neutral = Blue cable
Live = Brown cable
In the USA & Europe, it is required that all plugs are 3-pin type i.e. with Earth/Ground
connection.
In the UK, it is required that all mains plugs are fitted with 5A fuses.
Technical Specifications
SyncroLaser-R SyncroLaser-G
Power AC 120V 60Hz / 230V-250V 50/60Hz
Fuse 20mm Glass 2A Fast Blow
Laser diode Red laser diode Green laser diode
Wavelength 650 nm 532 nm
Dimensions 260 x 230 x 210 mm / 10.2 x 9.1 x 8.3 in
Weight 3.7 kg / 8.14 lbs