I Specifications
I Preparation for Servicing
I Adjustment Procedures
I Schematic Diagrams
I CBA’s
13" COLOR TV/VCR COMBINATION
SC313D
Sec. 2: Deck Mechanism Section
I Standard Maintenance
I Alignment for Mechanism
I Disassembly/Assembly of Mechanism
6313CD
Sec. 3: Exploded views
and Parts List Section
I Exploded views
I Parts List
EWC1303
IMPORTANT SAFETY NOTICE
Proper service and repair is important to the safe, reliable operation of all
Funai Equipment. The service procedures recommended by Funai and
described in this service manual are effective methods of performing service
operations. Some of these service special tools should be used when and as
recommended.
It is important to note that this service manual contains various CAUTIONS
and NOTICES which should be carefully read in order to minimize the risk of
personal injury to service personnel. The possibilit y exists that improper service methods may damage the equipment. It also is important to understand
that these CAUTIONS and NOTICES ARE NOT EXHAUSTIVE. Funai could not
possibly know, eval uate and advice the service tra de of all conceivable ways
in which service might be done or of the possible hazardous consequences of
each way. Consequently, Funai has not undertaken any such broad evaluation. Accordingly , a servicer who uses a service pr ocedure or tool which is not
recommended by Funai must first use all precautions thoroughly so that neither his safety nor the safe operation of the equipment will be jeop ardized by
the service method selected.
MAIN SECTION
13" COLOR TV/VCR COMBINATION
SC313D/6313CD/EWC1303
Sec. 1: Main Section
I Specifications
I Preparation for Servicing
I Adjustment Procedures
I Schematic Diagrams
I CBA’s
All items are measured across 8Ω resistor at speaker output terminal.
DescriptionConditionUnitNominalLimit
1. Audio Output Power (Max.)(R/P)W1.00.8
2. Audio S/N (W/LPF)(R/P)dB4036
3. Audio Distortion (W/LPF)(R/P)%3.05.0
4. Audio Freq. Response
(-10dB Ref. 1KHz)
Note: Nominal specific ations represent the design specificatio ns. All units should b e able to approxim ate these.
Some will exceed a nd so me may dro p slightl y below these spec ifica tions . Limit s pecific ations repre sent t he abs olute worst conditi on that still might be c onsidered acce ptable. In no case shoul d a unit fai l to meet li mit specific ations.
200Hz (R/P)
8kHz (R/P)
dB
dB
-2.0
0
-2.0±5.0
0±6.0
1-1-2T5400SP
IMPORTANT SAFETY PRECAUTIONS
Prior to shipment from the factory , our pro ducts are strictl y insp ected for re cogni zed product safety and el ectric al
codes of the countries in which they are to be sold. Howev er, in order to ma intain such c ompliance, it is equally
important to implement the following precautions when a set is being serviced.
Safety Precautions for TV Circuit
1. Before returning an instrum ent t o the c ustom -
er, always make a safety check of the entire instru-
ment, including, but not limited to, the following
items:
a. Be sure that no bui lt-in prot ective devices a re de-
fective and have b een defeated during servicing.
(1) Protective shields are provided on this chassis
to protect both the technician an d the customer.
Correctly replace all missing protective shields, including any removed for servicing convenience.
(2) When reinstalli ng the c hassis an d/or othe r assembly in the cabinet, be sure to put back in place
all protective de vices, in cluding but not li mited to,
nonmetallic control knobs, insulating fishpapers,
adjustment and compartment cove rs/shields, and
isolation resistor/capacitor networks. Do not oper-
ate this instrument or permit it to be operated
without all protective devices correctly installed and functioning. Servicers who defeat
safety features or fail to perform safety checks
may be liable for any resulting damage.
b. Be sure that there are no cabinet openings through
which an adult or child might be able to insert their
fingers and contact a hazardous voltage. Such
openings include, but are n ot limited to , (1) spacing between the picture tube and the cabinet
mask, (2) excessively wide cabinet ventilation
slots, and (3) an improperly fitted and/or incorrectly
secured cabinet back cover.
c. Antenna Cold Check - With the instrument AC
plug removed from any AC source, connect an
electrical jumper acr oss the two AC plug prongs.
Place the instrument AC switch in the on position.
Connect one lead of an oh mmeter to the A C plug
prongs tied together and to uch the other ohmme ter lead in turn to each tuner antenna input exposed terminal screw and, if applicable, to the
coaxial connector. If the measured resistance is
less than 1.0 mego hm or greater than 5 .2 megohm, an abnormality exi sts that must be correct ed
before the instrum ent is retur ned to the c ustom er.
Repeat this test with the ins trument AC switch in
the off position.
d. Leakage Current Hot Check - With the instru-
ment completely reassembled, plug the AC line
cord directly into a 120V AC outlet. (Do not use an
isolation transformer d uring thi s test.) Use a leak-
age current tester or a me tering syst em that com plies with American National Standards Institute
(ANSI) C101.1 Leakage Current for Appliances
and Underwriters Laborat ories (UL) 1410, (50.7).
With the instrument AC switc h first in the on posi tion and then in the o ff position, measure from a
known earth ground (metal water pipe, conduit,
etc.) to all exposed me tal parts of the instrument
(antennas, handle brac kets, metal cabinet, screw
heads, metallic overlays, c ontrol shafts, etc.), especially any exposed metal parts that offer an electrical return path to the chassis. Any current
measured must not excee d 0.5 milli-ampere. Re verse the instrument power cord plug in the outlet
and repeat the test.
READING SHOULD
NOT BE ABOVE 0.5 mA
LEAKAGE
DEVICE
BEING
TESTED
TEST ALL EXPOSED
METAL SURFACES
ALSO TEST WITH
PLUG REVERSED
USING AC
ADAPTER PLUG
AS REQUIRED
CURRENT
TESTER
EARTH
GROUND
ANY MEASUREMENTS NOT WITHIN THE LIMITS
SPECIFIED HEREIN INDICATE A POTENTIAL
SHOCK HAZARD THAT MUST BE ELIMINATED
BEFORE RETURNING THE INSTRUMENT TO
THE CUSTOMER OR BEFORE CONNECTING
THE ANTENNA OR AC CES SORI ES.
e. X-Radiation and High Voltage Limits - Because
the picture tube i s the prim ary potentia l source of
X-radiatio n in solid- state TV receiver s, it is s pecially constructed to prohibit X-radiation emissions.
For continued X-radiation pr otection, the replacement picture tube must be the same type as the
original. Also, because the picture tube shields
and mounting hardware perform an X-radiation
protection function, they must be correctly in place.
High voltage must be mea su re d ea ch tim e s er vic -
1-2-1SFTY_2
ing is performed that inv olves B+, horizontal deflection or high voltage. Correct operation of t he
X-radiation protection c ircu its a ls o m ust b e r ec on firmed each time they are serviced. (X-radiation
protection circuits also may be called "horiz ontal
disable" or "hold do wn.") R ead a nd a ppl y th e hi gh
voltage limits a nd, if the chassis is so e quipped,
the X-radiation protection circuit specifications given on instrument labe ls and i n the P roduct S afety
& X-Radiation Warning note on the service data
chassis schematic. High voltage is maintained
within specified limits by close tolerance safety-related components/adjus tme nts in th e hig h-vo lta ge
circuit. If high voltage exceeds specified limits,
check each component specified on the chassis
schematic and take corrective action.
2. Read and comply with all caution and safety-related notes on or inside th e receiver cabi net, on the
receiver chassis, or on the picture tube.
3. Design Alteration Warning - Do not alter or add
to the mechanical or electrical design of this TV receiver. Design alterations and additions, including,
but not limited to circuit modificatio ns and the addition of items such as auxiliary audio and/or video
output connections, mig ht alter the safety ch aracteristics of this receiver and create a hazard to the
user. Any design alter ations or addition s will void
the manufacturer's warr anty and may make you,
the servicer, responsible for personal injury or
property damage resulting therefrom.
4. Picture Tube Implosion Protection Warning -
The picture tube in this receiver employs integral
implosion protection. For continued implosion protection, replace the pic ture tube only with one of
the same type numbe r. Do not rem ove, install , or
otherwise handle the picture tube in any ma nner
without first putting on shatterproof goggles
equipped with side shields. People not so
equipped must be ke pt safely away while p icture
tubes are handled. Keep the picture tube away
from your body. Do not handl e the pictur e tu be b y
its neck. Some "in-line" picture tubes are equipped
with a permanently at tached deflection yoke ; because of potential hazard, do not try to remove
such "permanently attached" yokes from the picture tube.
5. Hot Chassis Warning -
a. Some TV receiver chassis are electrically connect-
ed directly to one conduc tor of th e AC powe r cor d
and maybe safety-serviced without an isolation
transformer only i f the AC power plug i s inserted
so that the chassis is connected to the ground side
of the AC power source. To confi rm that the AC
power plug is ins erted correctly, with an AC voltmeter, measure between the chassis and a known
earth ground. If a voltage reading in excess of 1.0V
is obtained, remove and reinsert the AC power
plug in the opposite polarity and again measure
the voltage potential between the chassis and a
known earth ground.
b. Some TV receiver chassis normally have 85V
AC(RMS) between ch assis and earth ground regardless of the AC plug polarity. This chassis can
be safety-serviced only with an isolation transformer inserted in the power line between the receiver
and the AC power so urce , for both pers onnel and
test equipment protection.
c. Some TV receiver chassis have a secondary
ground system in addition to the main chassis
ground. This se conda ry gro und s ystem is no t iso lated from the AC power line. The two ground systems are electrically separated by insulation
material that must not be defeated or altered.
6. Observe original lead dress. Take extra care to assure correct lead dres s in the following areas: a.
near sharp edge s, b. near thermal ly hot parts-be
sure that leads and components do not touch thermally hot parts, c. the AC su pply, d. high volta ge,
and e. antenna wiring. Alway s inspe ct in all ar eas
for pinched, out of plac e, or frayed wiring. C heck
AC power cord for damage.
7. Components, parts, and/or wiring that appear to
have overheated or are otherwise damaged
should be replaced with components, parts, or wiring that meet origin al specifications. Additiona lly,
determine the cause of ov erheating and/or damage and, if nece ss ar y, ta ke corre ct i ve ac ti o n to remove any potential safety hazard.
8. Product Safety Notice - Some electrical and mechanical parts have s pecia l safety- relat ed char acteristics which are often not evident from visual
inspection, nor can the protection they give necessarily be obtained by replaci ng them with components rated for higher voltage, wattage, etc.. Parts
that have special safety characteristics are identified by a ( # ) on schematics and in parts lists. Use
of a substitute replacement that does not have the
same safety characteristics as the recommended
replacement part might create sh ock, fire, and/or
other hazards. The Product's Safety is under review continuously and new instructions are issued
whenever appropriate . Prior to shi pment from the
factory, our products are strictly inspected to confirm with the recognized product safety and electrical codes of the countrie s in which they ar e to be
sold. However, in order to maintain such compliance, it is equal ly important to imp lement the following precautions when a set is being servic ed.
1-2-2SFTY_2
Precautions during Servicing
A. Parts identified b y the ( # ) symbo l are c ritica l for
safety.
Replace only with part number specified.
B. In addition to safety, othe r parts and assemblies
are specified for conformance with regulations applying to spurious radiati on. These must also be
replaced only with specified replacements.
Examples: RF converters, RF cables, noise blocking capacitors, and noise blocking filters, etc.
C. Use specified internal wiring. Note especially:
1) Wires covered with PVC tubing
2) Double insulated wires
3) High voltage leads
D. Use specified insulating materials for hazardous
live parts. Note especially:
1) Insulation Tape
2) PVC tubing
3) Spacers
4) Insulators for transistors.
E. When replacing AC primary side components
(transformers, power cord, etc.), wrap ends of
wires securely abo ut the terminals before so ldering.
F. Observe that the wires do not contact heat produc-
ing parts (heatsinks, oxide metal film resistors, fusible resistor s, etc.)
G. Check that replaced wires do not contact sharp
edged or pointed parts.
H. When a power cord has been replaced, check that
5~6 kg of force in any direction will not loosen it.
I. Also check areas surrounding repaired locations.
J. Use care that foreign objects (screws, solder drop-
lets, etc.) do not remain inside the set.
K. Crimp type wire connector
When replacing the power transformer in sets
where the connections between the power cord
and power transformer primary lead wires are performed using crimp type connectors, in order to
prevent shock hazards, perform carefully and precisely the following steps.
Replacement procedure
1) Remove the old con nector by cutti ng the wires at
a point close to the connector.
Important: Do not re-use a connector (discard it).
2) Strip about 15 mm of the in su lation from the en ds
of the wires. If the wires are stranded, twist the
strands to avoid frayed conductors.
3) Align the lengths of the wires to be connected . Insert the wires fully into the connector.
4) Use the crimping too l to crimp the met al slee ve at
the center position . Be sure to crimp fully to the
complete closure of the tool.
L. When connecting or disconnecting the VCR con-
nectors, f irst, di sconnec t the AC plug fr om AC supply socket.
1-2-3SFTY_2
Safety Check after Servicing
Examine the area surrounding the repaired location
for damage or deterioration. Observe that screws,
parts and wires have been returned to original positions. Afterwards, perform th e fol lo wing tes ts and c on firm the specified values in orde r to verify comp liance
with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance d istance (d) a nd (d') betwee n soldered terminals, and between terminals and surrounding metallic parts. (See Fig. 1)
T able 1 : Ratings for selected area
Chassis or Secondary Conductor
Primary Circuit Terminals
dd'
AC Line VoltageRegion
110 to 130 V
Note: This table is unofficial and for reference only.
Be sure to confirm the precise values.
USA or
CANADA
Clearance
Distance (d) (d')
≥ 3.2 mm
(0.126 inches)
2. Leakage Current Test
Confirm the specified (or lower) leakage current between B (earth ground, power cor d plug prongs) and
externally exposed accessible parts (RF terminals, antenna terminals, vid eo and audio input a nd outp ut terminals, microphone jacks, earphone jacks, etc.).
Measuring Method : (Power ON)
Insert load Z between B (earth ground, power cord
plug prongs) and exposed accessible parts. Use an
AC voltmeter to measure across both terminals of
load Z. See Fig. 2 and following table.
Table 2 : Leakage current ratings for selected areas
Exposed Accessible Part
Z
One side of
B
Power Cord Plug Prongs
Fig. 1
AC Voltmeter
(High Impedance)
Fig. 2
AC Line VoltageRegionLoad ZLeakage Current (i)Earth Ground (B) to:
110 to 130 V
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
USA or
CANADA
0.15µF CAP . & 1.5 kΩ
RES. connected in
parallel
1-2-4SFTY_2
i≤0.5mA rms
Exposed accessible
parts
STANDARD NOTES FOR SERVICING
Circuit Board Indications
1. The output pin of the 3 pin Regulator ICs is indicated as shown:
Top View
Out
2. For other ICs, pin 1 and every 5th pin is indica ted
as shown:
Pin 1
3. The 1st pin of every pin connector are indicated as
shown:
Pin 1
Input
In
Bottom View
5
10
How to Read the Values of the Rectangular Type Chip Components
Example:
(a) Resistor
473
= 473 = 47 [kΩ]
(b) Capacitor
= Not Shown
Caution:
Once chip parts (Resistors, Capacitors, Transistors,
etc.) are removed, they must not be reused. Always
use a new part.
Replacement Procedures for
(Top View)
(Top View)
Instructions for Connectors
1. When you conn ect or disconnect FFC cable (connector), be sure to disconnect the AC cord.
2. FFC ca ble (connector) should be inserted parallel
into the connector, not at an angle.
FFC Cable
Connector
CBA
* Be careful to avoid a short circuit.
[ CBA= Circuit Board Assembly ]
Leadless (Chip) Components
The Following Procedures are Recommended for the Replacement of the Leadless Components Used in this Unit.
1. Preparation for replacement
a. Soldering Iron
Use a pencil-type soldering iron (less than 30
watts).
b. Solder
Eutectic solder (Tin 63%, Lead 37%) is recommended.
c. Soldering time
Do not apply heat for more than 4 seconds.
d. Preheating
Leadless capacitor must be preheated before
installation. (130°C~150°C, for about two minutes.)
Notes:
a. Leadless components must not be reused after
removal.
b. Excessive mechanical stress and rubbing for the
component electrode must be avoided.
2. Removing the leadless component
Grasp the leadless component body with tweezers
and alternately apply heat to both electrodes. When
the solder on both electrodes has melted, remove
leadless component with a twisting motion.
1-3-1SFTY_5
Notes:
S
a. Do not atte mpt to lift the component off the boar d
until the component is completely disconnected
from the board by the twisting action.
b. Take care not to break the copper foil on the
printed board
3. Installing the leadless component
a. Presolder the contact points of the circuit board.
b. Press th e part downward wi th tweezers and solde r
both electrodes as shown below.
Note:
Do not glue the replacement leadless component to
the circuit board.
Tweezers
Chip
oldering Iron
Soldering Iron
Tweezers
Solder
Soldering Iron
2. Th e Flat Pack-IC on the CBA is affixed with gl ue,
so be careful not to break or damage the foil of
each pin or solder l ands u nder the IC when removing it.
1. Removal
With Hot - Air Flat Pack - IC Desoldering Machine:
a. Prepare the Hot - Air Flat Pack - IC Desoldering
Machine, then apply hot air to Flat Pack - IC (about
5~6 seconds). (Fig. S-1-1)
b. Remove the Flat Pack- IC with tweezers while
applying the hot air.
With Soldering Iron:
a. Using desoldering braid, remove the solder from all
pins of the Flat Pack - IC. When you use solder flux
which is applied to all pins of the Flat Pack - IC, you
can remove it easily. (Fig. S-1-3)
b. Lift eac h lead of the F lat Pack - IC upward one by
one, using a sharp pin or wire to which sol der will
not adhere (iron wi re). When hea ting the pins, u se
a fine tip soldering iron or a hot air Desoldering
Machine. (Fig. S-1-4)
With Iron Wire:
a. Using desoldering braid, remove the solder from all
pins of the Flat Pack - IC. When you use solder flux
which is applied to all pins of the Flat Pack - IC, you
can remove it easily. (Fig. S-1-3)
b. Affix the wire to a workbench or solid mounting
point, as sh own in Fig. S-1-5.
c. Pull up on the wire as the solder melts so as to lift
the IC leads from the CBA contact pads, while
heating the pins using a fine tip soldering iron or
hot air blower.
Note:
When using a sold ering iron, care must be taken
to ensure that the Flat Pa ck - IC is not being held
by glue, or when it is removed from the CBA, it
may be damaged if force is used.
Presolder
2. Installation
a. Using desoldering braid, remove the solder from
the foil of each pin of the Flat Pack - IC on the CBA,
so you can install a replacement Flat Pack - IC
more easily.
How to Remove / Install Flat Pack IC
Caution:
1. Do not apply the hot air to the chip parts around the
Flat Pack-IC for over 6 seconds as damage may
occur to the chip parts. Put Masking Tape around
the Flat Pack-IC to protect other parts from damage. (Fig. S-1-2)
b. The "I" mark on the Flat Pack - IC indicates p in 1
(See Fig. S-1-6). Make s ure t his mar k matches the
1 on the CBA when positioning for installation.
Then pre - solder the four corners of the Flat PackIC (See Fig. S-1-7).
c. Solder all pins of the Flat Pack - IC. Make sure that
none of the pins have solder bridges.
1-3-2SFTY_5
Hot Air Blower
Iron Wire
or
CBA
Masking
Tape
Tweezers
Flat Pack-IC
Fig. S-1-1
Hot-air
Flat Pack-IC
Desoldering
Machine
Flat Pack-IC
Fig. S-1-2
Desoldering Braid
To Solid
Mounting Point
Example :
Pin 1 of the Flat Pack-IC
is indicated by a " " mark.
Presolder
Soldering Iron
Fig. S-1-5
Fig. S-1-6
Fine Tip
Soldering Iron
Soldering Iron
Fig. S-1-3
Flat Pack-IC
CBA
Fig. S-1-7
Sharp
Pin
Fig. S-1-4
1-3-3SFTY_5
Instructions for Handling
Semiconductors
Electrostatic breakdown of the semiconductors may
occur due to a pot ential difference ca used by electrostatic charge during unpacking or repair work.
Ground for Human Body
Be sure to wear a gr oundi ng ba nd (1MΩ) that is prop erly grounded to rem ov e a ny s tatic ele ctr ici ty tha t m ay
be charged on the body.
Ground for Work Bench
Be sure to place a conductive sheet or copper plate
with proper grounding (1MΩ) on the work bench or
other surface, where the semiconductors are to be
placed. Because the static electricity charge on the
clothing will not escape through the body grounding
band, be careful to avoid contacting semiconductors to
clothing.
<Incorrect>
<Correct>
1MΩ
CBA
Grounding Band
1MΩ
CBA
Conductive Sheet or
Copper Plate
1-3-4SFTY_5
PREPARATION FOR SERVICING
)
How to Enter the Service Mode
Caution: 1
1. Optical sensors system are used for T ape Start and
End Sensor on this equipment. Read this page
carefully and prepare as described on this page
before starting to service ; otherwise, the unit may
operate unexpectedly.
Preparing: 1
1. Cover Q202 (START SENSOR) and Q201 (END
SENSOR) with Insulation Tape or enter the service
mode to activate Sensor Inhibition automatically.
Note: Avoid playing, rewinding or fast fo rwarding the
tape to its beginning o r end, because both Tape End
Sensors are not active.
How to Enter the Service Mode
1. Turn power on.
2. Use servic e remote control unit and press WAKEUP/SLEEP key. (See page1-7-1)
3. When e ntering the servic e mode, one of th e number (1, 2 or 4) will display at corners of the screen.
4. During the service mode, electrical adjustment
mode can be selected by remote con trol key. (Service remote control unit).
Details are as follows.
KeyAdjustment Mode
Picture adjustment mode: Press the
MENU button to change from BRT
(Bright), *CNT (Contrast), *CLR
MENU
0
1No need to use.
2
3No need to use.
4
5
(Color), *TNT(Tint) and *V-T. Press
CH UP/DOWN key to display Initial
Value. *Marked items are not necessary to adjust normally.
C-Trap and Y DL Time/Y SW LPF
adjustment mode: See adjustment
instructions page 1-7-2.
H adjustment mode: See adjustmentinstructions page 1-7-2.
Auto record mode: Perform recording
(15 Sec.)-->Stop-->Rewind (Zero
return) automatically.
Head switching point adjustment
mode: See adjustment instructions
page 1-7-5.
KeyAdjustment Mode
6No need to use.
Purity check mode: Shows Red,
7
8
9
Caution: 2
1. Th e deck mec hanism assem bly is mounte d on the
Main CBA directly, and SW211 (REC-SAFETY
SW) is mounted on the Main CBA. When deck
mechanism assembly is removed from the Main
CBA due to servici ng, this switch c an not be operated automatically.
Green, Blue or White cyclically on the
screen each time the “7” key is
pressed.
H. Shift adjustment mode: See adjustment instructions page 1-7-3.
V.size/V. shift adjustment: See adjustment instructions page 1-7-3.
Preparing: 2
1. To eject the tape, press the STOP/EJECT button
on the unit (or Remote Control).
2. Whe n yo u want to record during the Se rv ice m ode,
press the Rec button while depressing SW211
(REC-SAFETY SW) on the Main CBA.
Q201
(END SENSOR)
SW211
(REC-SAFETY SW)
Q202
(START SENSOR
MAIN CBA
1-4-1T5401PFS
N
•
-
X
Y
n
e
-
AUDIO
EARPHONE
VIDEO
STOP/EJECT REW
PLAY
F.FWD REC/OTRCHANNEL
VOLUME
POWER
1923 45 6 7 81310111412
POWER
WAKE-UP
/SLEEP
123
456
789
+100
0
EJECT
CHANNEL
RETURN
REW
PLAY
STOP
F.FWD
GAME
RECORD
PAUSE/STILL
SPEED
TIME SEARCH
CHANNEL
T-PROG.
CLEAR
COUNTER
RESET
DISPLAYMUTE
MENU
VOLUME
3
15
5
7
16
8
11
18
19
20
7
24
4
10
9
22
21
23
17
25
OPERATING CONTROLS AND FUNCTIONS
[ SC313D ]
This manual covers 13" and 19". The operation of the two models are exactly the same except
the appearance. 19" model is illustrated in this manual.
OTE:
We do not recommend the use of universal remote controls. Not all of the functions may be controlled with
a universal remote control.
If you decide to use a universal remote control with this unit, please be aware that the code number given
may not operate this unit. In this case, please call the manufacturer of the universal remote control.
TV/VCR FRONT PANEL -
1
REMOTE CONTROL -
VIDEO input jack– Connect to the video output
jack of your video camera or another VCR.
AUDIO input jack– Connect to the audio output
2
jack of your audio equipment, video camera or
another VCR.
3
POWER button– Press to turn TV/VCR on and
off. Press to activate timer recording.
VOLUME
4
X
Y
/
buttons– Adjust the volume
level.
CHANNEL K / L buttons– Press to select the
5
desired channels for viewing or recording.
You may display the main menu on the TV scree
by pressing repeatedly this button on the
TV/VCR.
TRACKING function– Press to minimize video
‘noise’ (lines or dots on screen) during playback
mode.
Remote Sensor Window– Receives the infrared
6
signals from the remote control.
STOP button– Press to stop the tape motion.
7
EJECT button– Press in the Stop mode to remov
tape from TV/VCR.
button–
L
Press to select setting modes from the on screen
•
menu.
Press to enter digits when setting program.
•
(for example: setting clock or timer program)
1-5-1T5400IB
-
REAR VIEW -
ANT.
2726
1
1
1
1
1
1
n
-
r
l
c-
to
-
8 REW button– Press to rewind the tape, or to view
the picture rapidly in reverse during playback
mode. (Rewind Search)
s
button–
Press to select a mode from a particular menu.
•
(for example: LANGUAGE or USER’S SET UP)
PLAY button– Press to begin playback.
9
K button–
Press to select setting modes from the on screen
•
menu.
Press to enter digits when setting program.
•
(for example: setting clock or timer program)
0 F.FWD button– Press to rapidly advance the tape,
or to view the picture rapidly in forward during
playback mode. (Forward Search)
button–
B
When setting program (for example: setting clock
•
or timer program), press to determine your selection and proceed to the next step you want to
input.
Press to determine setting modes from on screen
•
menu.
Press to select a mode from a particular menu.
•
(for example: LANGUAGE or USER’S SET UP)
1 REC button– Press for manual recording.
OTR button– Activates One Touch Recording.
(only on the TV/VCR)
2 RECORD indicator– Flashes during recording.
Lights up in the Stand-by mode for Timer
Recording.
3 EARPHONE jack– Connects to earphones (not
supplied) for personal listening. The size of jack is
1/8” monaural (3.5mm).
4 Cassette compartment
5 Number buttons– Press to select desired channels
for viewing or recording. To select channels from
1 to 9, first press the 0 button and then 1 to 9.
+100 button– When selecting cable channels
which are higher than 99, press this button first,
then press the last two digits. (To select channel
125, first press the “+100” button then press “2”
and “5”).
MENU button– Press to display the main menu o
16
the TV screen.
DISPLAY button– Display the counter or the cur
17
rent channel number and current time on the TV
screen.
SPEED button– Press to choose the desired
18
recording speed:SP/SLP.
T-PROG. CLEAR button–
19
ting of timer program.
COUNTER RESET button– Press to reset counte
to 0:00:00.
GAME button– Sets the game mode and externa
20
input mode at the same time.
21
TIME SEARCH button– Press to activate Time
Search mode.
PAUSE/STILL button– Press to temporarily stop
22
the tape during the recording or to view a still pi
ture during playback.
MUTE button– Mutes the sound. Press it again
23
resume sound.
CHANNEL RETURN button– Press to go back to
24
the previously viewed channel. For example,
pressing this button once will change channel dis
play from 3 (present channel) to 10 (previously
viewed channel), and pressing it a second time
will return from 10 to 3.
25
WAKE UP/SLEEP button– Sets the Wake up or
Sleep Timer.
Power cord– Connect to a standard
26
(120V/60Hz).
ANT. terminal– Connect to an antenna or cable
27
system.
Press to cancel a set-
AC outlet
1-5-2T5400IB
N
•
-
X
Y
n
e
-
AUDIO
EARPHONE
VIDEO
STOP/EJECT
REW
PLAY
F.FWD REC/OTRCHANNEL
VOLUME
POWER
1923 45 6 7 81310111412
POWER
WAKE-UP
/SLEEP
123
456
789
+100
0
EJECT
CHANNEL
RETURN
REW
PLAY
STOP
F.FWD
GAME
RECORD
PAUSE/STILL
SPEED
TIME SEARCH
CHANNEL
T-PROG.
CLEAR
COUNTER
RESET
DISPLAYMUTE
MENU
VOLUME
3
15
5
7
16
8
11
18
19
20
7
24
4
10
9
22
21
23
17
25
[ 6313CD ]
This manual covers 13" and 19". The operation of the two models are exactly the same except
the appearance. 19" model is illustrated in this manual.
OTE:
We do not recommend the use of universal remote controls. Not all of the functions may be controlled with
a universal remote control.
If you decide to use a universal remote control with this unit, please be aware that the code number given
may not operate this unit. In this case, please call the manufacturer of the universal remote control.
TV/VCR FRONT PANEL
VIDEO input jack– Connect to the video output
REMOTE CONTROL
1
jack of your video camera or another VCR.
AUDIO input jack– Connect to the audio output
2
jack of your audio equipment, video camera or
another VCR.
3
POWER button– Press to turn TV/VCR on and
off. Press to activate timer recording.
X
VOLUME
4
Y
/
buttons– Adjust the volume
level.
CHANNEL K / L buttons– Press to select the
5
desired channels for viewing or recording.
You may display the main menu on the TV scree
by pressing repeatedly this button on the
TV/VCR.
TRACKING function– Press to minimize video
‘noise’ (lines or dots on screen) during playback
mode.
Remote Sensor Window– Receives the infrared
6
signals from the remote control.
STOP button– Press to stop the tape motion.
7
EJECT button– Press in the Stop mode to remov
tape from TV/VCR.
button–
L
Press to select setting modes from the on screen
•
menu.
Press to enter digits when setting program.
•
(for example: setting clock or timer program)
1-5-3T5400IB
-
REAR VIEW
ANT.
2726
1
1
1
1
1
1
n
-
r
l
c-
to
-
8 REW button– Press to rewind the tape, or to view
the picture rapidly in reverse during playback
mode. (Rewind Search)
s
button–
Press to select a mode from a particular menu.
•
(for example: LANGUAGE or USER’S SET UP)
PLAY button– Press to begin playback.
9
K button–
Press to select setting modes from the on screen
•
menu.
Press to enter digits when setting program.
•
(for example: setting clock or timer program)
0 F.FWD button– Press to rapidly advance the tape,
or to view the picture rapidly in forward during
playback mode. (Forward Search)
button–
B
When setting program (for example: setting clock
•
or timer program), press to determine your selection and proceed to the next step you want to
input.
Press to determine setting modes from on screen
•
menu.
Press to select a mode from a particular menu.
•
(for example: LANGUAGE or USER’S SET UP)
1 REC button– Press for manual recording.
OTR button– Activates One Touch Recording.
(only on the TV/VCR)
2 RECORD indicator– Flashes during recording.
Lights up in the Stand-by mode for Timer
Recording.
3 EARPHONE jack– Connects to earphones (not
supplied) for personal listening. The size of jack is
1/8” monaural (3.5mm).
4 Cassette compartment
5 Number buttons– Press to select desired channels
for viewing or recording. To select channels from
1 to 9, first press the 0 button and then 1 to 9.
+100 button– When selecting cable channels
which are higher than 99, press this button first,
then press the last two digits. (To select channel
125, first press the “+100” button then press “2”
and “5”).
MENU button– Press to display the main menu o
16
the TV screen.
DISPLAY button– Display the counter or the cur
17
rent channel number and current time on the TV
screen.
SPEED button– Press to choose the desired
18
recording speed:SP/SLP.
T-PROG. CLEAR button–
19
ting of timer program.
COUNTER RESET button– Press to reset counte
to 0:00:00.
GAME button– Sets the game mode and externa
20
input mode at the same time.
21
TIME SEARCH button– Press to activate Time
Search mode.
PAUSE/STILL button– Press to temporarily stop
22
the tape during the recording or to view a still pi
ture during playback.
MUTE button– Mutes the sound. Press it again
23
resume sound.
CHANNEL RETURN button– Press to go back to
24
the previously viewed channel. For example,
pressing this button once will change channel dis
play from 3 (present channel) to 10 (previously
viewed channel), and pressing it a second time
will return from 10 to 3.
25
WAKE UP/SLEEP button– Sets the Wake up or
Sleep Timer.
Power cord– Connect to a standard
26
(120V/60Hz).
ANT. terminal– Connect to an antenna or cable
27
system.
Press to cancel a set-
AC outlet
1-5-4T5400IB
N
•
-
X
Y
n
R.
e
-
AUDIO
EARPHONE
VIDEO
STOP/EJECT
REW
PLAY
F.FWD REC/OTRCHANNEL
VOLUME
POWER
1923 45 6 7 81310111412
POWER
WAKE-UP
/SLEEP
123
456
789
+100
0
EJECT
CHANNEL
RETURN
REW
PLAY
STOP
F.FWD
GAME
RECORD
PAUSE/STILL
SPEED
TIME SEARCH
CHANNEL
T-PROG.
CLEAR
COUNTER
RESET
DISPLAYMUTE
MENU
VOLUME
3
15
5
7
16
8
11
18
19
20
7
24
4
10
9
22
21
23
17
25
[ EWC1303 ]
This manual covers 13" and 19". The operation of the two models are exactly the same except
the appearance. 19" model is illustrated in this manual.
OTE:
We do not recommend the use of universal remote controls. Not all of the functions may be controlled with
a universal remote control.
If you decide to use a universal remote control with this unit, please be aware that the code number given
may not operate this unit. In this case, please call the manufacturer of the universal remote control.
TV/VCR FRONT PANEL
REMOTE CONTROL
1
VIDEO input jack– Connect to the video output
jack of your video camera or another VCR.
AUDIO input jack– Connect to the audio output
2
jack of your audio equipment, video camera or
another VCR.
POWER button– Press to turn TV/VCR on and
3
off. Press to activate timer recording.
X
VOLUME
4
Y
/
buttons– Adjust the volume
level.
5
CHANNEL K / L buttons– Press to select the
desired channels for viewing or recording.
You may display the main menu on the TV scree
by pressing repeatedly this button on the TV/VC
TRACKING function– Press to minimize video
‘noise’ (lines or dots on screen) during playback
mode.
6
Remote Sensor Window– Receives the infrared
signals from the remote control.
STOP button– Press to stop the tape motion.
7
EJECT button– Press in the Stop mode to remov
tape from TV/VCR.
button–
L
Press to select setting modes from the on screen
•
menu.
Press to enter digits when setting program.
•
(for example: setting clock or timer program)
1-5-5T5400IB
-
REAR VIEW
ANT.
2726
1
1
1
1
1
1
n
-
r
l
c-
to
-
8 REW button– Press to rewind the tape, or to view
the picture rapidly in reverse during playback
mode. (Rewind Search)
s
button–
Press to select a mode from a particular menu.
•
(for example: LANGUAGE or USER’S SET UP)
PLAY button– Press to begin playback.
9
K button–
Press to select setting modes from the on screen
•
menu.
Press to enter digits when setting program.
•
(for example: setting clock or timer program)
0 F.FWD button– Press to rapidly advance the tape,
or to view the picture rapidly in forward during
playback mode. (Forward Search)
button–
B
When setting program (for example: setting clock
•
or timer program), press to determine your selection and proceed to the next step you want to
input.
Press to determine setting modes from on screen
•
menu.
Press to select a mode from a particular menu.
•
(for example: LANGUAGE or USER’S SET UP)
1 REC button– Press for manual recording.
OTR button– Activates One Touch Recording.
(only on the TV/VCR)
2 RECORD indicator– Flashes during recording.
Lights up in the Stand-by mode for Timer
Recording.
3 EARPHONE jack– Connects to earphones (not
supplied) for personal listening. The size of jack is
1/8” monaural (3.5mm).
4 Cassette compartment
5 Number buttons– Press to select desired channels
for viewing or recording. To select channels from
1 to 9, first press the 0 button and then 1 to 9.
+100 button– When selecting cable channels
which are higher than 99, press this button first,
then press the last two digits. (To select channel
125, first press the “+100” button then press “2”
and “5”).
MENU button– Press to display the main menu o
16
the TV screen.
DISPLAY button– Display the counter or the cur
17
rent channel number and current time on the TV
screen.
SPEED button– Press to choose the desired
18
recording speed:SP/SLP.
T-PROG. CLEAR button–
19
ting of timer program.
COUNTER RESET button– Press to reset counte
to 0:00:00.
GAME button– Sets the game mode and externa
20
input mode at the same time.
21
TIME SEARCH button– Press to activate Time
Search mode.
PAUSE/STILL button– Press to temporarily stop
22
the tape during the recording or to view a still pi
ture during playback.
MUTE button– Mutes the sound. Press it again
23
resume sound.
CHANNEL RETURN button– Press to go back to
24
the previously viewed channel. For example,
pressing this button once will change channel dis
play from 3 (present channel) to 10 (previously
viewed channel), and pressing it a second time
will return from 10 to 3.
25
WAKE UP/SLEEP button– Sets the Wake up or
Sleep Timer.
Power cord– Connect to a standard
26
(120V/60Hz).
ANT. terminal– Connect to an antenna or cable
27
system.
Press to cancel a set-
AC outlet
1-5-6T5400IB
CABINET DISASSEMBLY INSTRUCTIONS
1. Disassembly Flowchart
This flowchart indicates the disassembly s teps for the
cabinet parts and the CBA in order to gain acces s to
item(s) to be serv iced. W hen reasse mbling, f ollow the
steps in reverse order. Bend, route and dress the
cables as they were.
Caution !
When removing the CRT, be sure to discharge the
Anode Lead of the CRT with the CRT Ground Wire
before removing the Anode Cap.
[1] Rear Cabinet
[2] Tray Chassis
[3] Deck Unit
[4] Main CBA
[5] CRT
2. Disassembly Method
REMOVAL
ID/
LOC.
No.
[1]
[2]
PART
Rear
Cabinet
Tray
Chassis
REMOVE/
*UNHOOK/
Fig.
UNLOCK/RELEASE/
No.
UNPLUG/DESOLDER
1, 2 4(S-1),(S-2)1
Anode Cap, CN505,
3, 5
CRT CBA, CN601,
CN801, CN571
Note
2
(1): Order of s teps in Procedure . When reassem bling,
follow the steps in reverse order.These numbers
are also used as the Identifi ca tio n (loc ati on) No. of
parts in Figures.
(2): Parts to be removed or installed.
(3): Fig. No. showing Procedure of Part Location.
(4): Identification of part to be removed, unhooked,
unlocked, released, unplugged, unclamped, or
desoldered.
S=Screw, P=Spring, L=Locking Ta b, CN=Connec-
tor, *=Unhook, Unlock, Release, Unplug, or
Desolder
2(S-2) = two screws (S-2)
(5): Refer to the following Reference Notes in the
Table.
Reference Notes in the Table
1. Removal of the Rear Cabinet.
Remove screws 4(S-1) and (S-2).
Caution !
Discharge the Anode Lead of the CRT with the CRT
Ground Wire before removing the Anode Cap.
2. Removal of the Tray Chassis.
Discharge the Anode Lead of the CRT with the
CRT Ground Wire before removing the Anode Cap.
Disconnect the following: Anode Cap, CN505, CRT
CBA, CN601, CN571 and CN801. Then, pull the
Tray Chassis backward.
3. Removal of the Deck Unit.
Remove screws 7(S-3 ) and 2(S-4) . Then, desold er
connectors (CL201, CL40 1, CL 402 , CL 403) a nd li ft
up the Deck Unit.
4. Removal of the Main CBA.
Remove screws 6(S-5) and pull up the Main CBA.
5. Removal of the CRT.
Remove screw s 4( S-6 ) an d pu ll t he CRT backward.
7(S-3), 2(S-4),
[3]Deck Unit3, 5
[4]Main CBA3, 5 6(S-5)4
[5]CRT44(S-6)5
↓
(1)
↓
(2)
Desolder (CL201,
CL401, CL402,
CL403)
↓
(3)
↓
(4)
3
↓
(5)
1-6-1T5407DC
S-1
T
-2
S-2
[1] REAR CABINE
S-1
S-1
S-1
Fig. 1
S
S-1
S-1
[1] REAR CABINET
Fig. 2
1-6-2T5407DC
[2] TRAY CHASS
IS
S-3
[4] MAIN CBA
S-5
S-3
[3] DECK UNIT
S-3
S-5
S-5
S-5
S-4
S-4
S-5
Fig. 3
1-6-3T5407DC
S-6
A
ANODE CAP.
S-6
CRT CB
S-6
[5] CRT
S-6
Fig. 4
1-6-4T5407DC
ANODE
CRT
GND
MAIN CBA
CN505
SCREEN
TO SPEAKER
CN801
CL501A
FOCUS
CL403
CL502A
CRT CBA
TO DEGAUSS
COIL
CL502B
CN601
AC CORD
FE HEAD
CL401
CL201
CYLINDER
ASSEMBLY
CL402
AC HEAD
ASSEMBLY
CN571
CL501B
CAPSTAN
MOTOR
DECK UNIT
Fig. 5
1-6-5T5407DC
ELECTRICAL ADJUSTMENT INSTRUCTIONS
General Note:
"CBA" is abbreviation for "Circuit Board
Assembly."
NOTE:
Electrical adjustments are requir ed after replacing
circuit components and certain mechanical parts.
It is important to perform these adjustments only
after all repairs and replacements have been completed.
Also, do not attem pt thes e adj ustmen ts unles s the
proper equipment is available .
Test Equipment Required
1. NTSC Pa ttern Generator (Color Bar W/White Window, Red Color, Dot Pattern, Gray Scale, Monoscope, Multi-Burst)
2. AC Milli Voltmeter (RMS)
3. Alignment Tape (FL8A, FL8N), Blank Tape
4. DC Voltmeter
5. Oscilloscope: Dual-trace with 10:1 probe,
V-Range: 0.001~50V/Div,
F-Range: DC~AC-60MHz
6. Frequency Counter
7. Plastic Tip Driver
How to make service remote control
unit:
1. Prepare normal remote control unit. (Part No.
N0107UD) Remove 3 screws from the back lid.
(Fig. 1-1)
SCREW
How to Set up the Service mode:
Service Mode:
1. Use the service remote control unit.
2. Turn the power on.
3. Press "WAKE-UP/SLEEP" button on the service
remote control unit.
1. DC 105V (+B) Adjustment
Purpose: To obtain correct operation.
Symptom of Misadjustment: The picture is dark and
unit does not operate correctly.
Test pointAdj. PointModeInput
D613
Cathode
(+B)
C613(-)
(GND)
TapeM. EQ.Spec.
---
Note: D613 Cathode (+B), C613(-) (GND),
VR601 --- Main CBA
1. Connect the unit to AC Power Outlet.
2. Conne ct DC Volt Meter to D613 Cathode (+ B) and
C613(-) (GND).
3. Adj ust V R601 so that the vo ltage of D613 Cathode
(+B) becomes +105±0.5V DC.
VR601--------
DC Voltmeter
Plastic Tip Driver
+105±0.5V DC
2-1. H Adjustment
Remote control unit (Bottom)
2. Remote control unit: Part No. N0107UD
Add J1 (Jumper Wire) to the remote control CBA.
(Fig. 1-2)
J 1
J 1
Remote control CBA
Remote control CBA
Remote control unit: Part No. N0150UD
Cut off pin 10 of the remote con trol m ic ropr oces so r
and short circuit pins 10 and 17 of the microprocessor with a jumper wire
Fig. 1-1
Fig. 1-2
Fig. 1-2
Purpose: To get correct hor i zo nt a l po si t ion an d si ze of
screen image.
Symptom of Misadjustment: Horizontal position and
size of screen image may not be properly displayed.
Test pointAdj. PointModeInput
R583
TapeM. EQ.Spec.
---Frequency Counter 15.734kHz±300Hz
Note: R583 --- Main CBA
1. Connect Frequency Counter to R583.
2. Set the unit to the VIDEO mode and no input is
necessary. Enter the Service mode.
(See page 1-4-1.)
1-7-1T5401EA
CH o / p
buttons
Video---
3. Operate the unit for at least 20 minutes.
"
b
)
4. Press "2" button on the remote control unit and
2-3. Y DL Time/Y SW LPF
Adjustment
select H-Adj M ode. (Press "2" button , then displa y
will change H-Adj and AGC.)
5. Press "CH o / p" buttons on the remote control
unit so that the display will change "0" to "7."
At this moment, choose di spla y "0" to " 7" when the
Frequency counter display is closest to
15.734kHz±300Hz.
6. Turn the power off and on again.
2-2. C-Trap Adjustment
Purpose: To get minimum le akage of t he color signal
carrier.
Symptom of Misadjustment: If C-Trap Adjustment is
incorrect, stripes will appear on the screen.
Purpose: To get minimum leakag e of the color signal
carrier.
Symptom of Misadjustment: If Y DL Time Adjustment is incorrect, stripes will appear on the screen.
1. Enter the Service Mode. (See page 1-4-1.)
2. Y DL Time Adjustment: Press "0" button on the
service remote c ontro l uni t twic e to s how "D-T " on
the display.
Y SW LPF Adjustment: Press "0" button on the
service remote control unit four times to show
"Y SW" on the display.
3. Y DL Time Adjustment: Select "2" by pressing
"CH o / p" butto ns on the service rem ote control
to enter Y DL Time Adjustment mode.
Test pointAdj. PointModeInput
Y SW LPF Adjustment: Select "1" by pressing
"CH o / p" butto ns on the service rem ote control
J271
(B-OUT)
CH o / p
buttons
---Color Bar
to enter Y SW LPF Adjustment mode.
4. If needed, perform the following.
TapeM. EQ.Spec.
C-TRAP Adjustment (Factory mode
0"
utton
C-TRP 0C-TRP 1
CH
button
---
Oscilloscope
Pattern Generator
---
Figure
CH
button
minimum
"0" button
Y DL Time Adj TV Adjustment
CH
D-T TV 0D-T TV 1
button
Fig. 2
CH
button
Note: J271 (B-Out)--- Main CBA
1. Connect Oscilloscope to J271.
2. Input a color bar signal from RF input.
Enter the Service mode. (See page 1-4-1.)
3. Press "0" button on the remote control unit and
"0" button
Y DL Time Adj EXT/PB Adjustment
CH
D-T EXT 0D-T EXT 1
button
select C-TRAP Mode.
4. Press "CH o / p" buttons on the remote control
CH
button
unit so that the carrier leakage B-Out (3.58MHz)
value becomes minimum on the oscilloscope.
5. Turn the power off and on again.
"0" button
Y SW LPF Adjustment
CH
Y SW
button
0Y SW1
CH
button
1-7-2T5401EA
3. V. Size Adjustment
P
5. H. Shift Adjustment
Purpose: To obtain correct vertical height of screen
image.
Symptom of Misadjustment: If V. Size is incorrect,
vertical height of image on the screen may not be
properly displayed.
Test pointAdj. PointModeInput
---
TapeM. EQ.Spec.
---Pattern Generator90±5%
1. Enter the Service mode. (See page 1-4-1.)
Press "9" button on the remote control unit and
select V-S Mode. (Press "9" button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press "CH o / p" buttons on the remote control
unit so that the monoscope pattern is 90±5% of display size and the circle is round.
CH o / p
buttons
---Monoscope
4. V. Shift Adjustment
Purpose: To obtain correct vertical position of screen
image.
Symptom of Misadjustment: If V. position is incor-
rect, vertical positio n of image on the screen may not
be properly displayed.
Purpose: To obtain correct horizontal position and
size of screen image.
Symptom of Misadjustment: Horizontal position and
size of screen image may not be properly displayed.
Test pointAdj. PointModeInput
---
TapeM. EQ.Spec.
---Pattern Generator90±5%
1. Enter the Service mode. (See page 1-4-1.)
Press "8" button on the remote control unit and
select H-P Mode.
2. Input monoscope pattern.
3. Press "CH o / p" buttons on the remote control
unit so that the left and right side of the monoscope
pattern are equal to each other.
4. Turn the power off and on again.
CH o / p
buttons
---Monoscope
6. Cut-off Adjustment
Purpose: To adjust the beam cu rrent of R, G, B, and
screen voltage.
Symptom of Misadjustment: White color may be
reddish, greenish or bluish.
Test pointAdj. PointModeInput
Te st poi ntAdj. PointModeInput
---
TapeM. EQ.Spec.
---Pattern Generator90±5%
1. Enter the Service mode. (See page 1-4-1.)
Press "9" button on the remote control unit and
select V-P Mode. (Press "9" button then display will
change to V-P and V-S).
2. Input monoscope pattern.
3. Press "CH o / p" buttons on the remote control
unit so that the top and botto m of the monoscope
pattern are equal to each other.
CH o / p
buttons
---Monoscope
---Screen-ControlExt.
TapeM. EQ.Spec.
---Pattern Generator
Figure
ATTERN GENERATOR
EXT. INPUT
See Reference
Notes below
Black
Raster /
White
Raster
Fig. 3
1-7-3T5401EA
Notes: Screen Control FBT --- MAIN CBA
W
ar
F.B.T= Fly Back Transformer
Use the Remote Control Unit
1. Degauss the CRT and allow CRT to operate f or 20
minutes before starting the alignment.
2. Set the sc reen control to minimum position. Input
the Black raster signal from RF input.
3. Enter the Service Mode. (See page 1-4-1.)
Dimmed horizontal line appears on the CRT.
4. Press the "VOL p" button.
(Press "VOL p" then display will change CUT OFF/
DRIVE, VCO adjustment, Analog OSD adjustment).
5. Choose CUT OFF/DRIVE Mode then press "1" button. This adjustment mode is CUT OFF (R).
6. Press the "CH o / p" button until the horizontal line
becomes white.
7. Choose CUT OFF/DRIVE mode then press "2" button. This adjustment mo de is CUT OFF (G). Pres s
"CH o / p" until the horizontal line becomes white.
8. Choose CUT OFF/DRIVE Mode then press "3" button. This adjustment mode is CUT OFF (B ). Press
"CH o / p" until the horizontal line becomes white.
9. Input the White Raster Signal from Video In.
10.Choose CUT OFF/DRIVE mode then press "4."
Adjust the RED DRIVE as needed with the "CH o /p" buttons to get the followin g value, X= 286, Y=
294.
11.Choose CUT OFF/DRIVE mode then press "5."
Adjust the BLUE DRIVE as needed with the "CH o
/ p" buttons to get the following value, X= 286.
12.Turn the power off and on again.
7. Sub-Brightness Adjustment
Purpose: To get proper brightness.
Symptom of Misadjustment: If Sub-Brightness is
incorrect, proper brightness cannot be obtained by
adjusting the Brightness Control.
Test pointAdj. PointModeInput
---
TapeM. EQ.Spec.
---
hite
Note: SYMPTE Setup level --- 7 IRE
1. Enter the Service Mode. (See page 1-4-1.)
Then input SYMPTE signal from RF input.
2. Press MENU button. (Press MENU button then display will change B R T, C N T, T N T, V-T and SHP).
Select BRT and press "CH o / p" buttons so that
the bar is just visible (See above figure).
3. Turn the power off and on again.
CH o / p
buttons
Pattern
Generator
Figure
---
SYMPTE
7.5IRE
See below
Black
This b
just
visible
Fig. 4
1-7-4T5401EA
Loading...
+ 66 hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.