LaundryMate
®
LM600
LaundryMate® Valve
Operation & Maintenance Manual
Model Numbers Feature Highlights
LM600 LaundryMate® drain box with Valve • Installation straps for 16" O.C. single stud bay mounting
☐
or direct-to-stud mounting
Options/Modifications
A Water hammer arrestor size AA
☐
F Funnel
☐
P1 Crimp PEX
☐
P2 Cold expansion PEX
☐
• 1/2-14 NPSM with 1/2" female sweat inlets, 3/4" male
outlets
• Valve can be installed as bottom or top supply
• Accommodates 1 layer of 1/2" drywall up to 2 layers of
5/8" drywall
• 2'' PVC female direct glue drain
• Mounting straps
• 1/4 turn ball valves with color coded handles
Note: Append appropriate -sux to model number.
Compliance
- ASME A112.18.1/CSA B125.1
- ASSE 1010 (LM600A only)
- NSF 61.9, NSF 372
c
Dimensions
C
B
A
Warranty
Limited Lifetime - to the original end
purchaser in consumer/residential
installations.
10 Years - for commercial/industrial
installations. Refer to
www.symmons.com/warranty for
complete warranty information.
Measurements
F
A 7", 178 mm
B 6-5/8", 168 mm
C 17-1/2", 445 mm
D 2 1/2" 64mm
E 2 3/4" 70mm
F
G 16" O.C. REF, 406mm
Min. 1/2", 13 mm
Max. 1-1/4", 32 mm
D
G
Note: Dimensions subject to change without notice.
E

Installation
9
2
8
4
Section A
6
1
5
7
3
5
Section A (Steps 1-10)
1. Slide straps in mounting tabs
2. Attach strap to studs with user provided screws
3. Secure valve to box with two supplied nuts
4. Glue 2’’ PVC pipe into bottom of drain box
5. Knockout outside two holes of supply box for hot and
cold supply (shown in A.1)
6. Insert provided screws through tabs to secure box in
place
7. Connect supplies to valves with either:
a. Sweat connect
b. Included PEX Adapter connection that requires
thread sealant
8. If condensate drain is used, knockout back hole in
drain box (shown in A.1)
9. Knockout center plug of drain box with screwdriver
or hammer and use pliers to remove
Section B (Steps 10&11)
10 After finish wall is in place, press on covers
a. If finish wall is 1/2’’ thick, break tabs from cover
o
b. If 2 layers of 5/8” drywall leave tabs on
Funnel Installation:
Before installation of funnel deburr drain hole as necessary
11. If 1-1/4’’ drain line hose used, use provided clamp to
secure hose in place
8
Section C (Step 12)
Double Bay Installation:
12. Mount boxes on adjacent side of wall stud with
provided tabs. Continue steps starting at step 4.
Section D (Step 13)
Surface Mount Installation:
13. Drill holes out of box and use user provided screws
to attach to wall
Section A.1
13
12
11
Section B
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2021 Symmons Industries, Inc. ■ symmons.com ■ gethelp@symmons.com ■ ZV-3466 REV B ■ 031622
10
Section C
Section D