Location:
Identity
™
S-6702-TRM, S6702TRMTC
Tub/Shower Trim
Specification Submittal
Feature Highlights Options/Modifications
• Identity Tub/Shower Trim
• Requires Temptrol® Pressure Balancing Tub/Shower Valve
• Integral diverter control
• Metal lever handle
• 5-1/4" non-diverter tub spout
• 1 mode showerhead with easy to clean nozzles
• 2.5 gpm (9.5 L/min) ow restrictor
• Components shall be metal and nonmetallic construction, plated in
standard Polished Chrome nish
• Available with TA-10 ow control spindle and T-12A cap assembly
for Temptrol valve bodies installed with Test Cap
(order p/n S6702TRMTC)
Model Numbers
☐
S-6702-TRM
Tub/Shower Trim with integral diverter control,
Temptrol Pressure Balancing Tub/Shower Valve ordered separately
☐
S6702TRMTC
Tub/Shower Trim with integral diverter control,
TA-10 ow control spindle and T-12A cap assembly, must order
Temptrol valve with Test Cap
☐
-1.5 1.5 gpm (5.7 L/min) flow restrictor
☐
-2.0 2.0 gpm (7.6 L/min) flow restrictor
☐
-143 3 mode showerhead
☐
-145 5 mode showerhead
☐
-231 Super showerhead
☐
-EX Exposed column/slide bar, hand shower bracket
and hand shower wand (35EX)
☐
-L1 Less showerhead
☐
-LP Loop handle
☐
-LR Lever handle
☐
-REB Rebuild trim kit, includes TA-10 and TA-4
☐
-SS Slip spout on any tub/shower unit
☐
-VP Vandal resistant escutcheon screws in place of
standard screws
☐
-STN Satin Nickel finish
Compliance
• ASME A112.18.1/CSA B125.1
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete warranty information.
Go to www.symmons.com/register to register your Symmons product.
Note: Append appropriate -sufx to model number.

Dimensions
AA
EE
CC
BB
DD
Measurements
A Ø 2-1/2", 64 mm
B 5-7/8", 149 mm
C Ref. 77", 1956 mm
D 3-1/2", 89 mm
E
F Ref. 32", 813 mm
G Ref. 12", 305 mm
H 3-1/2", 89 mm
I 2-7/8", 73 mm
J
K
L 5-1/4", 133 mm
M Ø 2-1/2", 64 mm
6-3/8", 162 mm
Ø
Rough-in
2-3/8" ± 1/2", 60 mm ± 13 mm
Male 1/2-14 NPT tting
must protrude 4" (102 mm)
from nished wall
HH
GG
II
FF
MM
KK
LL
FLOORFLOOR
Notes:
1) Valve body and piping not included and shown as reference only.
2) Plaster shield (p/n T-176) for dry wall, plaster or other type walls 1/2" or greater.
3) All dimensions measured from nominal rough-in (see J as reference).
4) Dimensions subject to change without notice.
JJ
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621