Symmons SYM1737 Specifications

Page 1
Location:
CG
Identity
S-6702-TRM, S6702TRMTC Tub/Shower Trim
Specification Submittal
Feature Highlights Options/Modifications
Identity Tub/Shower Trim
Requires Temptrol® Pressure Balancing Tub/Shower Valve
Integral diverter control
Metal lever handle
5-1/4" non-diverter tub spout
1 mode showerhead with easy to clean nozzles
2.5 gpm (9.5 L/min) ow restrictor
Components shall be metal and nonmetallic construction, plated in standard Polished Chrome nish
Available with TA-10 ow control spindle and T-12A cap assembly for Temptrol valve bodies installed with Test Cap
(order p/n S6702TRMTC)
Model Numbers
S-6702-TRM
Tub/Shower Trim with integral diverter control, Temptrol Pressure Balancing Tub/Shower Valve ordered separately
S6702TRMTC
Tub/Shower Trim with integral diverter control, TA-10 ow control spindle and T-12A cap assembly, must order Temptrol valve with Test Cap
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-143 3 mode showerhead
-145 5 mode showerhead
-231 Super showerhead
-EX Exposed column/slide bar, hand shower bracket
and hand shower wand (35EX)
-L1 Less showerhead
-LP Loop handle
-LR Lever handle
-REB Rebuild trim kit, includes TA-10 and TA-4
-SS Slip spout on any tub/shower unit
-VP Vandal resistant escutcheon screws in place of
standard screws
-STN Satin Nickel finish
Compliance
ASME A112.18.1/CSA B125.1
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations. 5 Years - for industrial/commercial installations. Refer to www.symmons.com/warranty for complete warranty information. Go to www.symmons.com/register to register your Symmons product.
Note: Append appropriate -sufx to model number.
Page 2
Dimensions
AA
EE
CC
BB
DD
Measurements
A Ø 2-1/2", 64 mm B 5-7/8", 149 mm C Ref. 77", 1956 mm D 3-1/2", 89 mm
E
F Ref. 32", 813 mm G Ref. 12", 305 mm H 3-1/2", 89 mm
I 2-7/8", 73 mm
J
K
L 5-1/4", 133 mm
M Ø 2-1/2", 64 mm
6-3/8", 162 mm
Ø
Rough-in
2-3/8" ± 1/2", 60 mm ± 13 mm
Male 1/2-14 NPT tting
must protrude 4" (102 mm)
from nished wall
HH
GG
II
FF
MM
KK
LL
FLOORFLOOR
Notes:
1) Valve body and piping not included and shown as reference only.
2) Plaster shield (p/n T-176) for dry wall, plaster or other type walls 1/2" or greater.
3) All dimensions measured from nominal rough-in (see J as reference).
4) Dimensions subject to change without notice.
JJ
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Fax: (800) 961-9621
Copyright © 2019 Symmons Industries, Inc. symmons.com gethelp@symmons.com ZV-1547 REV B 083119
Loading...