Installation and Service Instructions
Model Numbers
SLW-4612
Lavatory faucet with pop-up drain
Alternate Finish Code
append to part numbers when applicable
-STN
--
Satin Nickel Chrome (standard)
Tools & Materials
Pipe
5/64"
Sealant
Plumbers
Putty
 Need Help?
Contact Symmons customer service at (800) 796-6667, (781) 848-2250 Email: gethelp@symmons.com Monday - Friday 7:30 am - 7:00 pm EST
Please check Symmons website
for technical help, the latest product information and warranty policy.
www.symmons.com/service
Visual Install Guide Lucetta Widespread Lavatory Faucet, SLW-4612
Step 2
Attach faucet handles
Step 3
Step 1
Step 1
Attach control valves to sink
Step 4
SConnect water supply lines
Step 10
Flush water supply lines
Non­Removable Removable
Step 6
Install stopper and
set eye position
Fasten drain body and
Attach drain body to drain trap
stopper stopper
tail piece to sink
Step 5
Step 9
Step 8
Connect lift rod, clevis strap, pivot rod and adjust linkage
Step 7
Attach pivot rod to drain body
PLUMBERS
PUTTY
Installation Instructions
Caution: If replacing an older faucet ensure water supply is
turned OFF before removing. en turn faucet control valves
ON to relieve water pressure.
Step 1 Attach control valves to sink
■ read ange nut about 2 inches down from threaded end of valve body. Ensure larger diameter end is facing up.
■ Insert valve body from underneath sink up through mounting hole. Ensure valve
collar
fastener
gasket
with red label (hot) is on the le and blue (cold) is on the right.
■ Place gasket over valve body and thread fastener onto valve body until stop is reached.
ange nut
valve body
■ Tighten ange nut under sink to secure valve body.
■ read collar onto outer threads of fastener until against surface of sink.
Step 2 Attach faucet handles
■ Turn valve spindles to the OFF position.
HOT - le valve,
clockwise
COLD - right valve,
screw
handles in OFF position
valve spindle
counter clockwise
■ Attach handle to valve spindle in OFF location and tighten screw in handle using a 5/64 inch Allen wrench.
Step 3 Attach faucet spout to sink
■ Unscrew tee and remove washer and nut from threaded end
of spout as shipped.
■ Insert end of spout through base and mounting hole. Fasten from under sink with washer and nut.
■ Tighten nut while ensuring spout and base are centered over mounting hole and at edge of washer is facing rear of sink.
washer
nut
tee
spout
base
Step 4 Connect water supply lines
■ Apply pipe sealant on male end of both
ex hoses
and thread into sides of tee.
■ read center of tee with ex hoses attached onto end of spout.
Note: is may
require about 4 inches of clearance to rotate.
valve
body
valve
outlet
& inlet
coupling
nut
tee
■ Attach loose end of ex hoses to valve outlets.
■ Plumb hot water supply to le valve inlet, cold water to right inlet and fasten with coupling nuts.
■ Check for leaks if only replacing faucet and drain is already installed by rst turning faucet handles to the OFF position and then turn water supply valves ON.
Step 5 Fasten drain body to sink
■ Remove stopper, unscrew ange and remove at
rubber washer from end of drain body as shipped.
■ Apply plumber’s putty around bottom of ange.
■ Move friction washer,
beveled washer and ange nut down away
from end of drain body.
■ Place ange into drain opening and screw drain body at least 2-3 turns until hand tight against ange. Apply putty or teon tape to tail piece and attach to drain body.
■ Position drain body so pivot cavity is facing rear of sink and then slide beveled washer and friction washer up against sink.
■ Tighten ange nut up against friction washer to evenly compress beveled washer while also ensuring ange is centered in drain opening.
Take care not to over tighten ange nut.
Page 2
ange nut
drain body
tail piece
Pipe
Sealant
spout
ex hose
ange
beveled washer
friction washer
pivot cavity
Step 6 Install stopper and set eye position
location
pivot rod
Stopper can be removable or non-removable determined by position of eye hole when later inserting pivot rod.
■ Insert stopper
non removable removable
stopper
ange
through ange opening and position eye hole.
Removing stopper
When installed in removable position, move pivot rod to the up position (li rod is in the down position when later installed). Eye hole will slide over end of pivot rod.
Step 7 Attach pivot rod to drain body
■ Remove retaining nut and outer seat
from pivot cavity.
■ Insert pivot rod into
pivot cavity so pivot ball is against inner seat and rod passes
under end of stopper according to selected eye hole position.
pivot rod retaining nut outer seat pivot ball inner seat pivot cavity
■ Slide outer seat over pivot rod with curved end against pivot ball.
■ Fasten pivot rod to drain body with retaining nut. Tighten using your ngers until ball is seated snug and pivot rod can move around freely.
Step 8 Connect lift rod and adjust linkage
■ Insert li rod through hole on rear of water spout.
■ Fasten end of pivot rod with spring clip through
location hole in clevis strap that is best aligned
to enable li rod also fasten to end of clevis strap when in the up position and stopper is in the closed position.
■ Insert li rod into end of clevis strap and fasten with thumb
screw at location where stopper can be easily
opened and closed. If necessary, select another location hole in clevis
strap and re-adjust li rod where fastened to clevis strap.
lift rod
clevis strap
thumb screw
holes
spring clip
Step 9 Attach drain body to drain trap
Step 10 Flush water supply lines
■ oroughly ush supply lines to prevent foreign matter, i.e. copper chips,
remove
aerator
sand, etc. from damaging the sealing surface inside control valves.
■ Remove aerator from end of faucet water spout.
■ Turn hot and cold faucet handles to full ON position and then open water supply valves and run long enough to ush supply lines thoroughly.
■ Turn faucet OFF, replace aerator and check for any leaks.
Care of faucet finish
Clean nish area by using mild soap and water or non-abrasive cleaner and then rinse immediately. A non-abrasive wax may be used to preserve nish area.
Valve cartridge replacement
Step 1 Remove faucet handle
Loosen screw using a 5/64 inch Allen wrench.
Step 2 Remove collar
Remove collar by turning counter clockwise.
Note: Ensure not to use any tool
that could scratch nish without taking protective measures.
Step 3 Remove cartridge
Using a wrench, turn hex nut on cartridge counter clockwise.
Note: Ensure valve assembly
under sink doesn’t rotate while turning nut.
Step 4 Insert new cartridge
Insert replacement cartridge and then tighten hex nut.
Step 5 Attach collar
Screw collar onto fastener and tighten using your hand.
Step 6 Attach faucet handle
■ Ensure cartridge spindle is rotated to the OFF position.
■ Attach handle in OFF location as shown in illustration and then tighten screw using a
5/64 inch Allen wrench.
Page 3
handle
screw
collar
spindle OFF
hot = cw cold = ccw
cartridge
fastener
handles set
in the OFF
position
*
Note: For faucets with an optional decorative
nish, append appropriate three letter sufx code to part numbers marked with an asterisk (*).
Dimensions Lucetta Widespread Lavatory Faucet, SLW-4612
8" (203 mm) min
16" (406 mm) max
4" (102 mm) min
1-15/16" (49 mm)
6-1/8"
(156 mm)
2-3/8" (60 mm)
2-1/16" dia. (52 mm)
Deck thickness
1-3/8" (35 mm) max
1" dia (25 mm)
Hole size
1-1/16" (27 mm) min 1-7/16" (37 mm) max
Flexible hose
(187 mm)
1/2"-14 NPSM
7-3/8"
5-1/8"
(130 mm)
13/16" dia. (21 mm)
1-1/8" (29 mm) min 1-1/2" (38 mm) max
4-7/8"
(124 mm)
2-7/16"
(62 mm) dia
Hole size
5/8" (16 mm)
Parts Assembly Lucetta Widespread Lavatory Faucet, SLW-4612
Replacement Parts
*
collar / escutcheon
Set screw requires 5/64” Allen wrench
Reference
replacement
parts table
standard
aerator
2.2 gpm
faucet
handle
lift rod
P-108CL12*
Part Number Item
WSF-CYL-TP-KIT
4"
(101 mm)
handle
set screw
fastener
gasket
valve
cartridge
stopper
P-100N
pop-up drain
assembly
RL-154LR
includes stopper
*
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667, (781) 848-2250 M-F 7:30 am - 7:00 pm EST or check our website at www.symmons.com for a list of Symmons distributors.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone (800) 796-6667 Website: www.symmons.com
Fax (800) 961-9621
Email: gethelp@symmons.com
KN-114E (hot)
OFF = CW
KN-113E (cold)
OFF = CCW
LN-15
*
FLR-110-1.5 FLR-110-1.0
KN-113E identified by groove
valve cartridge
aerator ow rates
aerator
2.2 gpm (8.3L/min)
* *
1.5 gpm (5.7L/min)
1.0 gpm (3.8L/min)
©2014 Symmons Industries, Inc. Printed in U.S.A.