Connect lift rod, clevis strap,
pivot rod and adjust linkage
Step 7
Attach pivot rod to drain body
PLUMBERS
PUTTY
Installation Instructions
Caution: If replacing an older faucet ensure water supply is
turned OFF before removing. en turn faucet control valves
ON to relieve water pressure.
Step 1 Attach control valves to sink
■ read ange nut about 2 inches down from threaded end
of valve body. Ensure larger diameter end is facing up.
■ Insert valve body from
underneath sink up
through mounting
hole. Ensure valve
collar
fastener
gasket
with red label (hot)
is on the le and blue
(cold) is on the right.
■ Place gasket over
valve body and
thread fastener
onto valve body
until stop is reached.
ange nut
valve body
■ Tighten ange nut
under sink to secure valve body.
■ read collar onto outer threads of fastener until against
surface of sink.
Step 2 Attach faucet handles
■ Turn valve spindles
to the OFF position.
HOT - le valve,
clockwise
COLD - right valve,
screw
handles in
OFF position
valve spindle
counter clockwise
■ Attach handle to
valve spindle in OFF
location and tighten
screw in handle
using a 5/64 inch
Allen wrench.
Step 3 Attach faucet spout to sink
■ Unscrew tee and remove washer and
nut from threaded end
of spout as shipped.
■ Insert end of spout
through base and
mounting hole.
Fasten from under sink
with washer and nut.
■ Tighten nut while
ensuring spout and
base are centered
over mounting hole
and at edge of washer
is facing rear of sink.
washer
nut
tee
spout
base
Step 4 Connect water supply lines
■ Apply pipe sealant
on male end of both
ex hoses
and thread into
sides of tee.
■ read center of
tee with ex hoses
attached onto
end of spout.
Note: is may
require about
4 inches of
clearance to rotate.
valve
body
valve
outlet
& inlet
coupling
nut
tee
■ Attach loose end
of ex hoses
to valve outlets.
■ Plumb hot water
supply to le valve inlet, cold water
to right inlet and
fasten with couplingnuts.
■ Check for leaks if only replacing faucet and drain is already
installed by rst turning faucet handles to the OFF position
and then turn water supply valves ON.
Step 5 Fasten drain body to sink
■ Remove stopper, unscrew
ange and remove at
rubber washer from end
of drain body as shipped.
■ Apply plumber’s putty
around bottom of ange.
■ Move friction washer,
beveled washer and
ange nut down away
from end of drain body.
■ Place ange into
drain opening and
screw drain body at
least 2-3 turns until
hand tight against ange.
Apply putty or teon
tape to tail piece and
attach to drain body.
■ Position drain body so
pivot cavity is facing rear
of sink and then slide beveled washer and friction washer up
against sink.
■ Tighten ange nut up against friction washer to evenly
compress beveled washer while also ensuring ange is
centered in drain opening.
Take care not to over tighten ange nut.
Page 2
ange nut
drain body
tail piece
Pipe
Sealant
spout
ex hose
ange
beveled
washer
friction
washer
pivot
cavity
Step 6 Install stopper and set eye position
location
pivot rod
Stopper can be removable
or non-removable
determined by position
of eye hole when later
inserting pivot rod.
■ Insert stopper
non
removable removable
stopper
ange
through ange
opening and
position eye hole.
Removing stopper
When installed in removable position, move pivot rod to
the up position (li rod is in the down position when later
installed). Eye hole will slide over end of pivot rod.
Step 7 Attach pivot rod to drain body
■ Remove retaining
nut and outer seat
from pivot cavity.
■ Insert pivot rod into
pivot cavity so pivot
ball is against inner
seat and rod passes
under end of stopper
according to selected
eye hole position.
■ Slide outer seat over
pivot rod with curved end against pivot ball.
■ Fasten pivot rod to drain body with retaining nut.
Tighten using your ngers until ball is seated snug
and pivot rod can move around freely.
Step 8 Connect lift rod and adjust linkage
■ Insert li rod through
hole on rear of water
spout.
■ Fasten end of pivot rod
with spring clip through
location hole in clevis
strap that is best aligned
to enable li rod also
fasten to end of clevis strap when in the up
position and stopper is
in the closed position.
■ Insert li rod into
end of clevis strap
and fasten with thumb
screw at location where
stopper can be easily
opened and closed.
If necessary, select another location hole in clevis
strap and re-adjust li rod where fastened to clevis strap.
lift rod
clevis strap
thumb
screw
holes
spring
clip
Step 9 Attach drain body to drain trap
Step 10 Flush water supply lines
■ oroughly ush supply
lines to prevent foreign
matter, i.e. copper chips,
remove
aerator
sand, etc. from damaging
the sealing surface
inside control valves.
■ Remove aerator
from end of faucet
water spout.
■ Turn hot and cold
faucet handles to full ON
position and then open water supply
valves and run long enough to ush supply lines thoroughly.
■ Turn faucet OFF, replace aerator and check for any leaks.
Care of faucet finish
Clean nish area by using mild soap and water or non-abrasive
cleaner and then rinse immediately. A non-abrasive wax may
be used to preserve nish area.
Valve cartridge replacement
Step 1 Remove faucet handle
Loosen screw using a 5/64 inch
Allen wrench.
Step 2 Remove collar
Remove collar by turning
counter clockwise.
Note: Ensure not to use any tool
that could scratch nish without
taking protective measures.
Step 3 Remove cartridge
Using a wrench, turn hex nut
on cartridge counter clockwise.
Note: Ensure valve assembly
under sink doesn’t rotate while
turning nut.
Step 4 Insert new cartridge
Insert replacement cartridge
and then tighten hex nut.
Step 5 Attach collar
Screw collar onto fastener and tighten using your hand.
Step 6 Attach faucet handle
■ Ensure cartridge spindle is rotated
to the OFF position.
■ Attach handle in OFF location
as shown in illustration and
then tighten screw using a
5/64 inch Allen wrench.
Page 3
handle
screw
collar
spindle OFF
hot = cw
cold = ccw
cartridge
fastener
handles set
in the OFF
position
*
Note: For faucets with an optional decorative
nish, append appropriate three letter sufx code to
part numbers marked with an asterisk (*).
Parts AssemblyLucetta Widespread Lavatory Faucet, SLW-4612
Replacement Parts
*
collar / escutcheon
Set screw requires
5/64” Allen wrench
Reference
replacement
parts table
standard
aerator
2.2 gpm
faucet
handle
lift rod
P-108CL12*
Part NumberItem
WSF-CYL-TP-KIT
4"
(101 mm)
handle
set screw
fastener
gasket
valve
cartridge
stopper
P-100N
pop-up drain
assembly
RL-154LR
includes stopper
*
Ordering replacement parts:
Call Symmons customer service at (800) 796-6667,
(781) 848-2250 M-F 7:30 am - 7:00 pm EST or
check our website at www.symmons.com for a
list of Symmons distributors.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone (800) 796-6667
Website: www.symmons.com