Identity
S-6700, S-6700TS, S-6701, S-6702
Operation & Maintenance Manual
™
Model Numbers
S-6700
Identity Shower System
S-6700TS
Identity Tub/Shower System
S-6701
Identity Shower System
S-6702
Identity Tub/Shower System
Modifications
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-143 3 mode showerhead
-145 5 mode showerhead
-231 2 mode showerhead
-CHKS Integral check stops - for use in
-IPS
-L/HD
-LP Loop handle
-LR Lever handle
-OP 13" oval plate
-REB-TRM
-REV Reverse coring, hot on right, cold on
-SS Slip spout on any tub/shower unit
-STN Satin Nickel finish
-TRM Trim only, valve not included
-X Integral service stops - allows water
CG
installations where a positive shut-off
device is used downstream of mixing valve
1/2" female IPS connections
Less showerhead
Rebuild trim kit
left, for back to back installations
shutoff at valve for service
Specification
S-6700
Shower system powered by the Temptrol® pressurebalancing valve with integrated volume control. Valve body
includes adjustable stop screw to limit handle turn.
S-6700TS
Tub/shower system powered by the Temptrol® pressurebalancing valve with integrated diverter. Valve body
includes adjustable stop screw to limit handle turn.
S-6701
Shower system powered by the Temptrol® pressurebalancing valve. Features adjustable stop screw to
limit handle turn, integrated volume control, 1 mode
showerhead with easy to clean rubber nozzles and
standard 2.5 gpm (9.5 L/min) ow restrictor.
S-6702
Tub/shower system powered by the Temptrol® pressurebalancing valve. Features adjustable stop screw to limit
handle turn, integrated diverter, non-diverter tub spout, 1
mode showerhead with easy to clean rubber nozzles and
standard 2.5 gpm (9.5 L/min) ow restrictor.
Components made from metal and nonmetallic materials,
plated in standard polished chrome nish.
Compliance
-ASME A112.18.1/CSA B125.1
-WaterSense 1.5 gpm (5.7 L/min)
Certied by
For California Residents
WARNING: This product contains chemicals known to the
State of California to cause cancer, birth defects, or other
reproductive harm.
CSA Group
Warranty
Note: Append appropriate -sufx to model number.
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Dimensions
FLOORFLOOR
LL
EE
FF
DD
AA
NN
OO
KK
MM
II
BB
CC
GG
PP
QQ
JJ
HH
Measurements
A 5-7/8", 149 mm
B 4-5/8", 117 mm
C 3-1/2", 89 mm
D 2-7/8", 73 mm
E Ref. 77", 1956 mm
Shower Valve Hole Size
F
G 3-1/2", 89 mm
H 7/8", 22 mm
I
J 12", 305 mm
K
L
M 5-1/2", 140 mm
N Ø 2-1/2", 64 mm
O Ø 3-1/8", 79 mm
P Ø 6-3/8", 162 mm
Q Ø 2-1/2", 64 mm
Min. Ø 3", 76 mm
Max. Ø 4", 102 mm
Rough-in
2-3/8" ± 1/2", 60 mm ± 13 mm
Male 1/2" NPT tting must
protrude 4" (102 mm)
from nished wall
S-6700TS, S-6702
Ref. 32", 813 mm
S-6700, S-6701
Ref. 42", 1067 mm
Notes:
1) All dimensions measured from nominal rough-in (see I as reference).
2) Dimensions subject to change without notice.
2
Parts Breakdown
Replacement Parts
C
B
Item Description Part Number
A Showerhead 672SH*
B
C
D
E
Shower Arm
Flange
Handle
Set Screw
300S*
RTS-084*
A
F Dome Cover T-19*
I
G
F
H
H
HOT
Water Supply
D
K
COLD
Water Supply
J
E
Notes:
1) Apply a bead of silicone around the perimeter of all shower trim
installed ush to the nished wall (less mounting plates and brackets).
Leave opening on bottom of escutcheons for weep hole.
2) Apply plumber tape to all threaded connections.
G
H
I
J
K Tub Spout 060*
*Note: Append -STN to part number for
Shower
Escutcheon Kit
Secondary
Handle
Satin Nickel nish.
(S-6700TS, S-6702)
S-6700TS-ESC*
(S-6700, S-6701)
S-6700-ESC*
RTS-083*
Tools Required for Installation
Adjustable
Wrench
Allen Wrench
3/32"
Phillips Head
Screwdriver
Plumber Tape
Silicone
3
Installation
Note:
For valve body installation, please
see valve body manual.
1) Install shower mounting plate (I)
to shower valve. Secure with two
screws (H).
I
1
H
H
2) Install secondary handle (J) to
shower escutcheon (G).
4) Install dome cover (F) to shower
valve by turning clockwise.
1
F
5) Install handle (D) to shower valve.
Secure handle with set screw (E).
7) Attach shower arm (B) and ange
(C) to vertical shower pipe. Turn
clockwise to tighten.
C
1
1
B
2
3
8) Install showerhead (A) to shower
arm (B). Turn clockwise to tighten.
B
1
G
J
3) Attach shower escutcheon (G) to
shower mounting plate (I).
G I
1
D
E
Note: Handle should be facing the 6
o’clock position.
6) Install tub spout (K) to pipe tting
Turn clockwise to tighten.
K
1
1
A
Note: Tabs should snap into place.
4
Operation (Temperature Control)
1) Turn shower handle counterclockwise approximately 1/4 turn
to put valve in cold position.
2) Turn shower handle counterclockwise approximately 1/2 turn
to put valve in warm position.
Operation (Diverter Control for S-6700TS, S-6702)
1) Turn diverter handle left for tub
spout operation.
3) Turn shower handle counterclockwise approximately 3/4 turn
to put valve in hot position.
2) Turn diverter handle right for showerhead operation.
Operation (Volume Control for S-6700, S-6701)
1) Turn volume control handle left for
high ow.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting.
Elements in water supply may cause
water staining on nish.
2) Turn volume control handle right
for low ow.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2017 Symmons Industries, Inc. ■ symmons.com ■ gethelp@symmons.com ■ ZV-3200 REV B ■ 082317