Identity
6700, 6701, 6702
Operation & Maintenance Manual
™
Model Numbers
6700
Identity Tub/Shower System
6701
Identity Shower System
6702
Identity Tub/Shower System
Modifications
-1.5 1.5 gpm (5.7 L/min) flow restrictor
-2.0 2.0 gpm (7.6 L/min) flow restrictor
-143 3 mode showerhead
-145 5 mode showerhead
-231 2 mode showerhead
-CHKS Integral check stops - for use in
installations where a positive shut-off
device is used downstream of mixing valve
-IPS
-L/HD
-LP Loop handle
-LR Lever handle
-OP 13" oval plate
-REB-TRM
-REV Reverse coring, hot on right, cold on
-SS Slip spout on any tub/shower unit
-STN Satin Nickel finish
-TRM Trim only, valve not included
-X Integral service stops - allows water
1/2" female IPS connections
Less showerhead
Rebuild trim kit
left, for back to back installations
shutoff at valve for service
Specification
6700
Tub/shower system powered by the Temptrol® pressurebalancing valve. Features adjustable stop screw to
limit handle turn. Components made from metal and
nonmetallic materials, plated in standard polished chrome
nish.
6701
Shower system powered by the Temptrol® pressurebalancing valve. Features adjustable stop screw to limit
handle turn, 1 mode showerhead with easy to clean rubber
nozzles and standard 2.5 gpm (9.5 L/min) ow restrictor.
Components made from metal and nonmetallic materials,
plated in standard polished chrome nish.
6702
Tub/shower system powered by the Temptrol® pressurebalancing valve. Features adjustable stop screw to limit
handle turn, diverter tub spout, 1 mode showerhead with
easy to clean rubber nozzles and standard 2.5 gpm
(9.5 L/min) ow restrictor. Components made from metal
and nonmetallic materials, plated in standard polished
chrome nish.
Compliance
-ASME A112.18.1/CSA B125.1
-WaterSense 1.5 gpm (5.7 L/min)
2.0 gpm (7.6 L/min)
For California Residents
WARNING: This product contains chemicals known to
the State of California to cause cancer, birth defects, or
other reproductive harm.
Certied by
CSA Group
Warranty
Limited Lifetime - to the original end purchaser in
consumer/residential installations.
5 Years - for industrial/commercial installations.
Refer to www.symmons.com/warranty for complete
warranty information.
Note: Append appropriate -sufx to model number.
Dimensions
FLOORFLOOR
KK
EE
FF
DD
AA MM
NN
JJ
LL
II
BB
CC
GG
OO
PP
HH
Measurements
A 5-7/8", 149 mm
B 4-5/8", 117 mm
C 3-1/2", 89 mm
D 2-7/8", 73 mm
E Ref. 77", 1956 mm
Shower Valve Hole Size
F
G 3-1/2", 89 mm
H 12", 305 mm
I
J
K
L 5-1/4", 133 mm
M Ø 2-1/2", 64 mm
N Ø 3-1/8", 79 mm
O Ø 6-3/8", 162 mm
P Ø 2-1/2", 64 mm
Min. Ø 3", 76 mm
Max. Ø 4", 102 mm
Rough-in
2-3/8" ± 1/2", 60 mm ± 13 mm
Male 1/2" NPT tting must
protrude 4" (102 mm)
from nished wall
6700, 6702
Ref. 32", 813 mm
6701
Ref. 42", 1067 mm
Notes:
1) All dimensions measured from nominal rough-in (see I as reference).
2) Dimensions subject to change without notice.
2
Parts Breakdown
Replacement Parts
C
Item Description Part Number
B
A
I
G
F
H
H
HOT
Water Supply
D
J
COLD
Water Supply
A Showerhead 672SH*
B
C
D
E
F Dome Cover T-19*
G
H
*Note: Append -STN to part number for
Shower Arm
Flange
Handle
Set Screw
Shower
Escutcheon Kit
I
J Tub Spout 054*
Satin Nickel nish.
300S*
RTS-084*
6700-ESC*
Tools Required for Installation
Adjustable
Wrench
Allen Wrench
3/32"
E
Phillips Head
Screwdriver
Notes:
1) Apply a bead of silicone around the perimeter of all shower trim installed
ush to the nished wall (less mounting plates and brackets).
Leave opening on bottom of escutcheons for weep hole.
2) Apply plumber tape to all threaded connections.
Plumber Tape
Silicone
3
Installation
Note:
For valve body installation, please
see valve body manual.
1) Install shower mounting plate (I)
to shower valve. Secure with two
screws (H).
I
1
H
H
2) Attach shower escutcheon (G) to
shower mounting plate (I).
3) Install dome cover (F) to shower
valve by turning clockwise.
G
1
F
4) Install shower handle (D) to shower
valve. Secure shower handle with
set screw (E).
5) Install tub spout (J) to pipe tting
Turn clockwise to tighten.
J
6) Attach shower arm (B) and ange
(C) to vertical shower pipe. Turn
clockwise to tighten.
1
C
1
1
B
2
G I
Note: Tabs should snap into place.
1
D
E
Note: Handle should be facing the
6 o’clock position.
3
7) Install showerhead (A) to shower
arm (B). Turn clockwise to tighten.
B
1
1
A
4
Operation (Temperature Control)
1) Turn shower handle counterclockwise approximately 1/4 turn
to put valve in cold position.
2) Turn shower handle counterclockwise approximately 1/2 turn
to put valve in warm position.
Operation (Diverter Control for 6702 only)
1) Diverter lever in down position for
tub spout operation.
3) Turn shower handle counterclockwise approximately 3/4 turn
to put valve in hot position.
2) Diverter lever in up position for
shower operation.
Troubleshooting Chart
Problem Cause Solution
Finish is spotting.
Elements in water supply may cause
water staining on nish.
Clean nished trim area with a soft
cloth using mild soap and water or a
non-abrasive cleaner and then quickly
rinse with water.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621
Copyright © 2017 Symmons Industries, Inc. ■ symmons.com ■ gethelp@symmons.com ■ ZV-3196 REV B ■ 021617