Symmons Carrington SLW-4412 Installation And Service Instructions Manual

Carrington
Widespread Lavatory Faucet SLW-4412 Installation and Service Instructions
Caution: Be sure to turn o hot and cold water supplies before installing or servicing faucet.
care not to over tighten the locknut, causing damage
Installation Procedure
1. Push valve bodies through holes in sink from
underneath. Make sure ange nuts and mounting washers are on underside of sink. Valve with red striped
hose (hot) is on the le and blue (cold) is on the right. Put gasket (LN-129) over valve body. read escutcheon (LN-128) onto valve body. e top of the valve spindle should measure 1-7/8” from mounting surface (See rough in drawing).
2. read collar (LN-112) on to valve body until it reaches
the escutcheon (LN-128).
3. CRP handle installation: Ensure valve spindle is rotated
to the OFF position. Place handle on valve spindle and thread screw (LN-121A) into valve.
4. Tighten ange nuts and mounting washers from
underneath sink and secure with mounting screws if nec essar y.
5. Install spout (LN-254A) and centerbody (LN-188)
through center in sink hole from above sink. Secure spout to sink with washer (LN-138) and nut (SPF-26). Washer (LN-138) at side should face back of the sink. read tee (LN-189) to bottom of centerbody (LN-188).
6. read ex hose adapters into tee (LN-189) using pipe
sealant on the threads. Attach ex hoses to ex hose adapters.
7. Connect hot supply to le tube and cold supply to right
tube using appropriate connectors.
8. Pop-up drain installation:
a ) Remove pop-up plug, tail piece and ange from
the drain body. Make sure that locknut is threaded all the way down onto the body with at friction washer in middle and beveled washer on top.
b ) Apply plumbers putty or sealant to bottom of
ange.
c ) Install drain body through drain opening in
lavatory and screw ange onto the drain body making sure that the threads are completely engaged for proper sealing and strength of the connection. Apply joint compound to all threaded parts to insure proper seal. Apply putty or teon tape to tail piece before attaching to drain body.
d ) Tighten locknut to compress the beveled ange
evenly across the bottom of the drain opening taking
8. It is very important to thoroughly ush the supply lines
Replacing cartridge (KN-113 or KN-114):
1. Remove plug button (LN-243H or LN-243C), loosen
2. Remove collar (LN-112) by turning counter clockwise.
3. Place wrench on cartridge hex nut (KN-113, KN-114).
4. Install new cartridge. Turn cartridge with wrench until
to the lavatory. Apply teon tape (clockwise) on tail piece and thread into outlet of body.
e ) Insert pop-up plug and pivot rod into body and
tighten retaining nut until the ball is seated on the ball washer.
Note: e pop-up plug can be installed either in the removable or non-removable position, depending on the location of the hole located in the guide at the bottom of the plug.
f ) Slide the pivot rod through one side of the spring
clip, then the appropriate adjustment hole and then other side of the spring clip.
g ) Insert li rod through faucet housing and the top of
the li strap and secure it in place by tightening the screw.
Note: To insure proper operation of li rod and pop-up, some adjustment of the linkage may be required.
ere are two possible adjustment points:
1) li strap to li rod
2) li strap to pivot rod
to prevent foreign matter, i.e. copper chips, sand, stones, etc. from damaging the sealing surfaces of cartridge.
Remove aerator and open hot and cold to full open then open both supplies. Let water run through hot and cold long enough to ush supply lines thoroughly. Shut o faucet and replace aerator. Check for leaks.
Phillips head screw (LN-121A) and remove handle (LN-
177).
Caution: Do not use wrench as this may damage the surface nish.
Turn wrench counterclockwise until cartridge is removed.
cartridge does not turn easily then turn 1/4 to 1/2 turn further. Reassemble handle in reverse fashion.
Dimensions Carrington Two Handle Widespread Lavatory Faucet, SLW-4412
8"(203 mm) min
16"(406 mm) max
2-5/16" dia (59 mm)
4" (102 mm) min
7-1/8"
(181 mm)
2" (51 mm)
2-7/16"
(62 mm)
Deck thickness
1-3/8" (35 mm) max
Hole size
1-1/4" (32 mm)
5/8" dia (16 mm)
1-1/2" (38 mm) min 1-5/8" (41 mm) max
1/2"-14 NPSM
Flexible hose
Note: Dimensions subject to change without notice
Parts Assembly Carrington Two Handle Widespread Lavatory Faucet, SLW-4412
KN-114 Valve cartridge (1) L-26 O-ring (2) (plug button) LN-112* Collar (2) LN-121A Handle screw, M4x10, SS, panhead (2) LN-128* Escutcheon, widespread (2) LN-129 Gasket, Escutcheon (2) LN-138 Washer LN-150 O-ring (2) LN-177* Cross handle (2) LN-185 Gasket, spout LN-188 Centerbody LN-189 Centerbody tee LN-243C Plug button, porcelain (cold) LN-243H Plug button, porcelain (hot) LN-254A* Spout P-108CL12* Lift rod (for pop-up drain assembly) SPF-26 Nut, Hex (centerbody)
WSF-CRP-KIT Handle kit (qty 2 handles) *For Decorative Finish Faucets add sufx to parts
marked with an asterisk as follows: Sufx -STN Radiance® satin nish
Aerator
(ow regulator)
Part Number Standard Aerator
(red stripe on hot hose)
LN-243H (1)
Handle kit (2 handles)
KN-114
LN-254A
Aerator insert
2.2 gpm
LN-188
Mounting screws
LN-189
Flex hose adapter
Flex hose
5-13/16" (148 mm)
4-5/32"
(106 mm)
Hole size
3/4" (19 mm)
1-9/16" (40 mm)
7-1/4"
(184 mm)
1-7/8"
(48 mm)
1" dia
(25 mm)
LN-243C (1) L-26 (2) LN-121A (2) LN-177 (2) LN-112 (2) LN-128 (2) LN-129 (2)
P-108CL12
KN-114
LN-185 LN-138 SPF-26 LN-150
Mounting washer Flange nut
(blue stripe on cold hose)
2.2 gpm (8.3L/min) ----
1.5 gpm (5.7L/min) LN-741
1.0 gpm (3.8L/min ----
For California Residents WARNING: This product contains chemicals known to the State of California to cause cancer, birth defects, or other reproductive harm.
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 Website: symmons.com
Copyright © 2017 Symmons Industries, Inc.
Fax: (800) 961-9621
Email: gethelp@symmons.com
*
ZV-577 REV D 020317
P-26* Grid drain (optional)
RL-154LR* Pop-up drain assembly (without lift rod)
Loading...