Canterbury
Roman Tub Faucet SRT-4570
Installation and Service Instructions
®
Model Numbers
SRT-4570 ..............Chrome finish
SRT-4570-STN
.....Satin Nickel finish
Tools & Materials
1/8"
1 2 3 4
Quick Install Guide Canterbury Roman Tub Faucet, SRT-4570
Step 7
Attach water spout
Need Help?
Symmons customer service:
Phone: (800) 796-6667
Email: gethelp@symmons.com
Monday - Friday 7:30 am - 6:00 pm EST
www.symmons.com/service
Compliance
ASME A112.18.1/CSA B125.1
Step 8
Flush water supply lines
Step 5
Attach handles
Step 3
Mount valve assembly
Step 4
Attach valve assembly
Step 2
Solder valve assembly together
Step 1
Cut copper tubing to length
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth defects,
or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
Step 6
Connect water supply lines
and check for leaks
nished deck
Installation Instructions
Caution: If replacing an older faucet ensure water supply is
turned OFF before removing and then turn faucet handles ON
to relieve water pressure.
Step 1 Cut copper tubing to length
Length = (d) minus 2-1/4 inches (57 mm) divided by 2.
center to center distance (d)*
1/2" (12.7 mm) copper tubing
Step 3 Mount valve assembly to deck
nished deck
front view
red
(hot)
blue (cold)
Step 4 Attach valve assembly to deck
Example:
If center to center distance (d) is 14 inches.
-
14 inches minus 2-1/4 inches = 11-3/4 inches.
-
11-3/4 inches divided by 2 = 5-7/8 inches.
-
Cut 2 copper tubes into 5-7/8 inch lengths.
-
* Maximum distance (d) with supplied
copper tubing is 18-1/4 inches (463 mm)
Step 2 Solder valve assembly together
nished deck
front view
D1
Thread down until
stop is reached
D1 = D2
D2
Ensure valves are
parallel aligned
when soldering.
Page 2