Note: Instructions replace document
ZV-782 as of June 2012.
Lavatory faucet with
pop-up drain
Alternate Finish Code
append to part numbers when applicable
-STN
--
Satin Nickel
Chrome (standard)
Quick Install Guide Allura Widespread Lavatory Faucet, SLW-4712
Attach control valves to sink
Tools & Materials
Pipe
Sealant
Compliance
- ASME A112.18.1/CSA B125.1
- NSF/ANSI 61.9, NSF/ANSI 372
- WaterSense 1.0 & 1.5 gpm
Step 1
Step 1
5/64"
Plumbers
Putty
Need Help?
Contact Symmons customer service at
(800) 796-6667, (781) 848-2250
Email: customerservice@symmons.com
Monday - Friday 7:30 am - 7:00 pm EST
Please check Symmons website
for technical help, the latest product
information and warranty policy.
www.symmons.com/service
Certied by
Step 2
Attach center spout to sink
Step 9
Flush water supply lines
SConnect water supply lines
Step 5
Install stopper and
set eye position
Fasten drain body and
tail piece to sink
Attach drain body to drain trap
Step 3
NonRemovable Removable
Stopper Stopper
Step 4
Step 8
Step 7
Connect lift rod, clevis strap,
pivot rod and adjust linkage
Step 6
Attach pivot rod to drain body
Installation Instructions
PLUMBERS
PUTTY
Installation Instructions
Caution: If replacing an older faucet ensure water supply is
turned OFF before removing. en turn both faucet handles to
the ON position to relieve water pressure.
Step 1 Attach control valves to sink
■ read ange nut
down about 2 inches
from threaded end
of valve body.
fastener
gasket
■ Insert valve body
from underneath
sink up through
mounting hole.
Ensure valve with
red striped hose (hot)
is on the le and blue
(cold) is on the right.
valve body
mounting washer
ange nut
mounting screws
■ Place gasket over valve
body and thread
fastener onto valve
body until fastener
is secured tightly to
valve body.
■ Ensure spindle
is rotated to the
OFF position.
plug button
screw
handle
spindle OFF
hot = cw
cold = ccw
Fasten handle to top
of spindle located
in OFF position as
shown in illustration.
■ Press plug button into
top of handle.
■ Tighten ange nut
and mounting washer
under sink and secure with mounting screws if necessary.
Step 2 Attach center spout to sink
■ Unscrew tee and
remove washer and
nut from threaded
end of spout as
typically shipped.
■ Insert through
mounting hole
in sink and then
fasten from under
sink with washer
and nut.
■ Tighten nut while
ensuring spout
is centered over
mounting hole and
at edge of washer is
facing rear of sink.
washer
nut
tee
spout
Step 3 Connect water supply lines
■ read tee onto
end of spout.
Note: is may
require 4 inches
of clearance.
■ Apply pipe
sealant on both
ex hose adapters.
read into side
of tee.
valve
outlet
& inlet
ex hose
adapter
tee
■ Attach ex hoses
to ex hose
adapters.
Pipe
Sealant
■ Plumb hot
water supply to
le valve body
ex hose
inlet, cold water
to right inlet
(1/2 inch supply hoses not included).
■ Check for leaks if only replacing faucet and drain is already
installed by rst turning faucet handles to the OFF position
and then turn water supply valves ON.
Step 4 Fasten drain body to sink
■ Remove stopper, unscrew ange and remove at rubber
washer from end
of drain body as shipped.
■ Apply plumber’s putty
around bottom of ange.
■ Move friction washer,
beveled washer and
ange nut down away
from end of drain body.
■ Place ange into drain
opening and from under
sink screw drain body
into ange at least
turns until hand tight.
Apply putty or teon tape
to tail piece and attach to
drain body.
■ Position drain body so pivot cavity is facing rear of
sink and then slide beveled washer and friction washer
up against sink.
■ Tighten ange nut up
against friction washer to
evenly compress beveled washer while also ensuring ange is
centered in drain opening.
Stopper can be removable
or non-removable
determined by position
of eye hole when
inserting pivot rod.
non
removable removable
■ Insert stopper
through ange
opening and rotate to
position eye hole.
Removable stopper
When installed in removable position, move pivot rod to
the up position (li rod is in the down position when later
installed). Eye hole will slide over end of pivot rod.
Step 6 Attach pivot rod to drain body
■ Remove retaining nut and outer seat from pivot cavity.
■ Insert pivot rod into
pivot cavity so pivot
ball is against inner
seat and rod passes
under end of stopper
according to selected
eye hole position.
■ Insert outer seat
over pivot rod with
curved end against
pivot ball.
■ Fasten pivot rod to drain body with retaining nut
and tighten using your ngers until ball is seated
snug and pivot rod can move around freely.
Step 7 Connect lift rod and adjust linkage
■ Insert li rod through hole on top of water spout.
■ Fasten end of pivot rod with spring clip
through location hole
in clevis strap that is
best aligned to enable
li rod also fasten to
end of clevis strap when
in the up position and
stopper is in the closed
position.
■ Insert li rod into
end of clevis strap
and fasten with
thumb screw at location
where stopper can be
easily opened and
closed.
If necessary, select
another location hole
in clevis strap and re-adjust li rod where fastened to clevis
strap
clevis strap
stopper
ange
lift rod
thumb
screw
location
holes
spring
clip
pivot rod
Step 8 Flush water supply lines
oroughly ush the supply lines to prevent foreign matter, i.e.
copper chips, sand, etc.
from damaging the
sealing surface inside
control valves.
■ Remove aerator from
end of faucet water
remove
aerator
outlet by rotating
counter clockwise.
■ Turn hot and cold
faucet handles
to full ON position,
open water supply
valves
and run long enough to ush supply lines thoroughly.
■ Turn faucet OFF, replace aerator, and check for any water leaks.
Care of faucet finish
Clean nish area by using mild soap and water or non-abrasive
cleaner and then rinse immediately. A non-abrasive wax may
be used to preserve nish area.
Valve cartridge replacement
Remove faucet handle
■ Pry loose and remove plug button
using your nger.
■ Remove Phillips head screw
in center of handle.
■ Li o handle from
cartridge spindle.
Remove cartridge
Using a wrench, turn hex nut
on cartridge counter clockwise.
Note: Ensure valve assembly doesn’t
rotate under sink while turning nut.
Insert new cartridge
Insert replacement cartridge into
center of valve and tighten hex nut
using a wrench.
Attach handle
■ Ensure cartridgespindle is
rotated to the OFF position.
■ Attach handle located
in the OFF position as
shown in illustration.
■ Insert screw into
center of handle
and replace plug button.
Page 3
plug button
screw
handle
spindle OFF
hot = cw
cold = ccw
cartridge
valve
handles set in
the OFF position
LN-15
FLR-110-1.5
FLR-110-1.0
aerator ow rates
2.2 gpm (8.3L/min)
1.5 gpm (5.7L/min)
1.0 gpm (3.8L/min)
Parts AssemblyAllura Widespread Lavatory Faucet, SLW-4712
*
faucets with an optional decorative nish, append
appropriate three letter nish sufx code to part
numbers marked with an asterisk (
*
4-1/2"
(114 mm)
6-5/16"
(160 mm)
5/8" dia (16 mm)
Hole size
1-1/8" (29 mm) min
1-1/2" (38 mm) max
5/8" (16 mm)
3-1/4"
(83 mm)
1-5/8" (42 mm)
2-1/2"
(64 mm)
3-1/8" (79 mm)
1" dia. (25 mm)
Hole size
1-1/16" (27 mm) min
1-7/16" (37 mm) max
4" (102 mm)
Flexible hose
Deck thickness
1-3/8" (35 mm) max.
Dimensions
Allura Widespread Lavatory Faucet, SLW-4712
2-1/4" dia
(58 mm)
2-5/16" dia
(59 mm)
1/2"-14 NPSM
8" (203 mm)
Note: Dimensions subject to change without notice.
lift rod
P-108CL12
standard aerator
faucet handle
reference table
valve cartridge
reference table
(red stripe on hot hose)
WARNING: This product can expose you to chemicals including lead, which is known to the state of California to cause cancer, birth
defects, or other reproductive harm. For more information, go to www.P65Warnings.ca.gov.
pop-up drain
assembly
RL-154LR
includes lift rod
and stopper
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184 ■ Phone: (800) 796-6667 ■ Fax: (800) 961-9621