Symmons 1-805S Installation Manual

2
3
/4"
70mm
6
1
/4"
159mm
3
1
"
79mm
1
7
/8
"
48mm
2
1
"
54mm
stops
1
1
/
16
"
27mm
7
"
178mm
4
1
/4"
108mm
6
1
"
165mm
3
1
"
76mm
36
" (914mm)
bewteen units
36
" (914mm)
bewteen units
3
1
/
8
"
79mm
9
1
"
241mm
31
3
/8
"
797mm
17
1
"
445mm
4
3
"
111mm
4
1
"
108mm
6
"
152mm
stops accessible thru bottom
Shower Head
Height
floor line
1-805 Series (standard)
standard unit
short unit
1-806 Series (short)
INSTALLATION INSTRUCTIONS
Product meets ANSI A112.18.1M Flow rate: 2.5 gpm (9.5 L/min)
Drilling pattern for valve and piping assembly
®
Hydapipe
INSTALLATION:
1. With the special wrench provided remove the four vandal-proof screws holding the stainless steel unit cover to valve and piping assembly (two screws at head bracket and two screws at valve). Remove unit cover. Note: head bracket is fastened to unit cover and is removed with it.
2. Mount valve and piping assembly to wall at speci­fied height with screws and anchors provided. Connect supply piping.
3. When looking at the drawing supplied, starting with the cover labeled (A), place horizontal cover on the wall so that the opening straddles the verti­cal unit. You then insert anchor and screw in the horizontal cover to secure it to the wall.
4. The rest of the horizontal covers will follow in alphabetical order. You will need to leave a ¾” gap between each horizontal cover.
5. An HP-26 horizontal strap will cover the gap that is left. It also provides support for the sections.
6. Each corner cover is provided with tabs on them so that, the horizontal pieces will fit snuggly into
the corner pieces.
7. All copper tubing supplied for crossover fittings on these units are cut to length and should not be altered
8. Replace unit covering and fasten with vandal proof screws.
9. Install showerhead
Recommended head heights
Men _______________________________ 6’4”
Boys, Senior High ___________________ 6’0”
Boys, Junior High ___________________ 5’7”
Boys, Elementary ____________________ 5’4”
Women ____________________________ 6’0”
Girls, Senior High____________________ 5’8”
Girls, Junior High ____________________ 5’5”
Girls, Elementary ____________________ 4’2”
HP-21 ENDCAP
800 HORIZONTAL COVER (PER JOB SPEC)
3/4" GAP LEFT BETWEEN ALL COVERS
HP-26
HP–5 SOAP DISH HP–4 COVER PLATE (WHEN SOAP DISH IS NOT USED)
C-13 Dome cover HP-2 Shield (standard unit) HP-3 Shield (short unit) HP-5 Soap dish HP-6 Nameplate HP-7 Screw HP-8 Shower head bracket HP-10 Body cover HP-10A O-ring HP-14 Screw HP-14A Washer HP-14B Star plastic anchors HP-21 Endcap HP-23 TEE (2 required) HP-26 Cover Strap HP-30 Crossover Fitting HY-1A Piping assembly (standard unit) HY-1B Piping assembly (short unit) J-32B O-ring
RC-14 Handle SC-13C Dial SC-15A Set screw SC-18 Lock nut S2H-8D Set screw SC-3 Renewable seat SC-7 Packing nut SC-9 Cold washer retainer SC-10 Hot washer SC-10A Screws SC-11 Cold washer SC-17 Packing SC-19 Cap gasket SC-26 Limit stop with o-ring 4-131M Super shower head
C-5 Spindle assembly C-50 Renewable seat socket wrench KIT-B Washer and gasket kit SC-2 Cap assembly SC-3 Renewable seat unit complete HP-17ASB Stop assembly
Tools required for installation:
Slotted screwdriver, Phillips screwdriver, soldering equipment, adjustable wrench, channel lock pliers, hex socket keys (1/8” and 3/32”), electric drill with 1/4” drill bit, HY-50 screwdriver (provided)
INDIVIDUAL PARTS INDIVIDUAL PARTS COMPOSITE PARTS
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800) 796-6667, (781) 848-2250 Fax ( 8 00) 961- 9 621, (781 ) 84 3 -384 9 Website: www.sy m mons .com Email: c u s t o merser v i c e @ s y m m o n s .com
©2007, 2008 Symmons Industries, Inc. Printed in U.S.A. ZV-480 050208