1-7460-X
5"
127mm
6 1/2''
165mm
12''
305mm
2 5/8" 67mm
15"
381mm
approx.
6"-152mm
right or left
approx.
40"
1016mm
approx.
41"
1041mm
approx.
30"
762mm
7/8"
22mm
5/8"
16mm
approx.
36"
914mm
12"
305mm
12"
305mm
1/4'' 6mm
1/4"
6mm
1/2"
3/4"
3/4"
24 5/8" 625mm
25 1/2" 648mm
finished wall
hot and cold inlets
shower discharge
floor line
Male 1/2'' I.P . S. thread must protrude 7/8''
(22mm) from finished wall for proper
installation of street ell and flange.
adjustment
into stud or install
screw bar support
proper backing
All piping including valve inlets and outlets 3/4" except where noted otherwise.
Water Dance ® Two Wall Shower System
Water Dance System includes High-Flo™ Pressure-Balancing shower valve with integral stops, metal finish insert lever handle and adjustable stop screw to limit handle turn. Triple outlet index lever diverter allows up to two functions to flow simultaneously. Euro-Flo three mode shower head with arm and flange. Three Euro-Flo adjustable body sprays. Euro-Flo three mode wall/hand shower with flexible metal hose, in-line vacuum breaker, wall connection and flange. 24” slide bar for hand shower mounting.
SYMMONS PRODUCTS MEET
ANSI A112.18.1M, EPA ‘92
AND ALL KNOWN FLOW RATE
REQUIREMENTS.
Shower Heads and Hand Showers
2.5 GPM (9.5 L/min)
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 (800) 796-6667, (781) 848-2250 Fax (800) 9 6 1 - 9 6 21, (781) 8 4 3 - 3 8 4 9 Website: www.symmons. c o m Email: c us t o me r s er v i c e @ sy m m on s . co m
Job/Location
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Engineer
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Contractor
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
This drawing to be used for rough-in installation only. All floor to center dimensions optional. Concealed piping and fittings not furnished by manufacturer. For ADA compliance (Americans with Disabilities Act) consult ADAAG or your state regulations for proper product choice and mounting locations. For complete installation, adjustment and service information see installa­tion instructions.
©2003, 2008 Symmons Industries, Inc. Printed in U.S.A. 050108