![](/html/0a/0aa4/0aa4cfd2f05afc5a7c0ba31fde7e0a727391f223c823d71369da4c3ff976405a/bg1.png)
1-217-FS
Safetymix ® Tub and
Shower System with
Hand Spray
Safetymix® Pressure-Balancing mixing valve with lever handle and
adjustable stop screw to limit handle turn. Super shower head with
arm and flange. Lever diverter with integral volume control. Tub spout.
Wall/hand shower with flexible 5’ metal hose, in-line vacuum breaker,
wall connection and flange. Wall hook for hand shower mounting.
Modifications:
Suffix X: Integral service stops—allows water shut-off at valve for
service
Suffix X-3/4: 3/4” valve to increase flow approximately 20%
Suffix X-REV: Reverse coring, hot on right, cold on left, for back to back
installations with integral stops only
Suffix QD: Quick-disconnect for hand spray units
Male 1/2" IPS thread must protrude
3/8" (10 mm) from nished wall for proper
installation of street ell and ange.
Screw wall hook
5-5/8"
(143 mm)
into stud or install
proper backing.
nished
wall
shower
discharge
SYMMONS PRODUCTS MEET
ASME A112.18.1
AND ALL KNOWN FLOW RATE
REQUIREMENTS.
Shower Heads and Hand Showers
2.5 GPM (9.5 L/min)
Job/Location
6"
(152 mm)
6" (152 mm)
min. without stops
9" (229 mm)
min. with stops
Note:
2-3/8" (60 mm) min. 3" (76 mm) max.
2-5/16" (59 mm) xed dim. metal stall.
Valve inlets and outlets are 1/2" (13 mm)
IPS connections.
(914 mm)
approx.
14"
(356 mm)
approx.
36"
approx.
42"
(1067 mm)
oor line
9-1/2"
(240 mm)
10"
(254 mm)
min.
22"
(559 mm)
hot and
cold inlets
see note
4"
(101 mm)
Note: Dimensions subject to
change without notice.
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone: (800) 796-6667
www.symmons.com
■ Fax: (800) 961-9621
■ gethelp@symmons.com
3-1/2"
(89 mm)
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Engineer
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Contractor
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
This drawing to be used for rough-in installation
only. All floor to center dimensions optional.
Concealed piping and fittings not furnished by
manufacturer. For ADA compliance (Americans
with Disabilities Act) consult ADAAG or your
state regulations for proper product choice and
mounting locations. For complete installation,
adjustment and service information see installation instructions.
Copyright © 2015 Symmons Industries, Inc.
■ ZV-1439 REV A ■ 090215