1-117VT-FS
Male 1/2" IPS thread must protrude
Visu-Temp ® Shower
System with Hand Spray
Visu-Temp® Pressure-Balancing mixing valve with integral thermometer
and adjustable stop screw to limit handle turn. Lever diverter with volume control for shower head and hand spray. Super shower head with
arm and flange. Wall/hand shower with flexible 5’ metal hose, in-line
vacuum breaker, wall connection and flange.
Modifications:
Suffix X: Integral service stops—allows water shut-off at valve for
service
Suffix X-CHKS Integral check stops
Suffix X-3/4 3/4” valve to increase flow approximately 20%
Suffix NU NU-Arm head bracket in place of 300 arm and flange
Suffix B30 30” adjusting bar in place of wall hook
Suffix 6: 6’ hose in place of standard 5’ hose
Suffix R: Vinyl hose in place of standard metal hose
Suffix 1.5: 1.5 (5.7 L/min) Flow rate restrictor
Suffix 2.0: 2.0 (7.6 L/min) Flow rate restrictor
3/8" (10 mm) from nished wall for proper
installation of street ell and ange.
5-5/8"
(143 mm)
Screw wall hook
into stud or install
proper backing.
shower
discharge
SYMMONS PRODUCTS MEET
ASME A112.18.1
AND ALL KNOWN FLOW RATE
REQUIREMENTS.
Shower Heads and Hand Showers
2.5 GPM (9.5 L/min)
Job/Location
. . . . . . . . . . . . . . . . . . . . . . . . . .
9-1/2"
(240 mm)
4"
(101 mm)
6"
(152 mm)
5"
(127 mm)
min. without stops
7"
(178 mm)
min. with stops
Note:
2-1/2" (64 mm) min. 3" (76 mm) max.
On 2" x 4" construction, use 2-1/2" (64 mm)
min. rough-in. Valve inlets and outlets are
1/2" (13 mm) IPS connections.
approx.
22"
(559 mm)
approx.
38"
(965 mm)
approx.
40"
(1016 mm)
oor line
7"
(178 mm)
min.
nished wall
hot and cold inlets
see note
Note: Dimensions subject to
change without notice.
3-1/2"
(89 mm)
Symmons Industries, Inc. ■ 31 Brooks Drive ■ Braintree, MA 02184
Phone: (800) 796-6667
www.symmons.com
■ Fax: (800) 961-9621
■ gethelp@symmons.com
. . . . . . . . . . . . . . . . . . . . . . . . . .
Engineer
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Contractor
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
This drawing to be used for roughin installation only. All floor to center
dimensions optional. Concealed piping
and fittings not furnished by manufacturer.
Dimensions are for ADA compliance
(Americans with Disabilities Act) consult
ADAAG or your state regulations for proper
product choice and mounting locations. For
complete installation, adjustment and service
information see installation instructions.
Copyright © 2015 Symmons Industries, Inc.
■ ZV-1434 REV A ■ 082815