Symmons 1-117VT-FS User Manual

1-117VT-FS
Male 1/2" IPS thread must protrude
Visu-Temp ® Shower System with Hand Spray
Visu-Temp® Pressure-Balancing mixing valve with integral thermometer and adjustable stop screw to limit handle turn. Lever diverter with vol­ume control for shower head and hand spray. Super shower head with arm and flange. Wall/hand shower with flexible 5’ metal hose, in-line vacuum breaker, wall connection and flange.
Modifications:
Suffix X: Integral service stops—allows water shut-off at valve for
service
Suffix X-CHKS Integral check stops
Suffix X-3/4 3/4” valve to increase flow approximately 20%
Suffix NU NU-Arm head bracket in place of 300 arm and flange
Suffix B30 30” adjusting bar in place of wall hook
Suffix 6: 6’ hose in place of standard 5’ hose
Suffix R: Vinyl hose in place of standard metal hose
Suffix 1.5: 1.5 (5.7 L/min) Flow rate restrictor
Suffix 2.0: 2.0 (7.6 L/min) Flow rate restrictor
3/8" (10 mm) from nished wall for proper installation of street ell and ange.
5-5/8"
(143 mm)
Screw wall hook into stud or install proper backing.
shower discharge
SYMMONS PRODUCTS MEET
ASME A112.18.1
AND ALL KNOWN FLOW RATE
REQUIREMENTS.
Shower Heads and Hand Showers
2.5 GPM (9.5 L/min)
Job/Location
. . . . . . . . . . . . . . . . . . . . . . . . . .
9-1/2"
(240 mm)
4"
(101 mm)
6"
(152 mm)
5"
(127 mm)
min. without stops
7"
(178 mm)
min. with stops
Note: 2-1/2" (64 mm) min. 3" (76 mm) max. On 2" x 4" construction, use 2-1/2" (64 mm) min. rough-in. Valve inlets and outlets are 1/2" (13 mm) IPS connections.
approx.
22"
(559 mm)
approx.
38"
(965 mm)
approx.
40"
(1016 mm)
oor line
7"
(178 mm)
min.
nished wall
hot and cold inlets
see note
Note: Dimensions subject to change without notice.
3-1/2"
(89 mm)
Symmons Industries, Inc. 31 Brooks Drive Braintree, MA 02184 Phone: (800) 796-6667 www.symmons.com
gethelp@symmons.com
. . . . . . . . . . . . . . . . . . . . . . . . . .
Engineer
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
Contractor
. . . . . . . . . . . . . . . . . . . . . . . . . .
. . . . . . . . . . . . . . . . . . . . . . . . . .
This drawing to be used for rough­in installation only. All floor to center
dimensions optional. Concealed piping and fittings not furnished by manufacturer. Dimensions are for ADA compliance (Americans with Disabilities Act) consult ADAAG or your state regulations for proper product choice and mounting locations. For complete installation, adjustment and service information see installation instructions.
Copyright © 2015 Symmons Industries, Inc.
ZV-1434 REV A 082815