Symetrix RC-6000 User Manual

1
QUICK START GUIDE: RC-6000 Remote Control
Safety
G The lightning flash with arrowhead
symbol within an equilateral triangle is intended to alert the user of the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product (i.e. this Quick Start Guide).
G CAUTION: To prevent electric shock,
do not use the polarized plug supplied with the device with any extension cord, receptacle, or other outlet unless the prongs can be fully inserted.
G Power Source: Use only the power
cord and connector specified for the product and your operating locale. A protective ground connection, by way of the grounding conductor in the power cord, is essential for safe operation. The appliance inlet and coupler shall remain readily operable once the apparatus has been installed.
G Lithium Battery Caution: Observe the
correct polarity when changing the lithium battery. There is a danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. Dispose of used batteries according to local disposal requirements.
G User Serviceable Parts: There are no
user serviceable parts inside this Symetrix product. In case of failure, customers inside the U.S. should refer all servicing to the Symetrix factory. Customers outside the U.S. should refer all servicing to an authorized Symetrix distributor. Distributor contact information is available online at: http://www.symetrix.co.
"7*4
/&1"40673*3
*MOFTFUSPVWFBMJOUFSJFVSBVDVOFQJFDFQPVSWBOUFOUSFSFQBSÊFMVTBHFS
4&&08/&34."/6"-70*3$")*&3%*/4536$5*0/4
4BESFTTFSBVOSFQBSBUFVSDPNQÊUFOU
3*426&%&$)0$&-&$53*26&
/PVTFSTFSWJDFBCMFQBSUTJOTJEF3FGFSTFSWJDJOHUPRVBMJGJFETFSWJDFQFSTPOOFM
$"65*0/
8"3/*/(
503&%6$&5)&3*4,0''*3&03 &-&$53*$4)0$,%0/05&9104&
5)*4&26*1.&/5503"*/03.0*4563&
%0/0501&/
3*4,0'&-&$53*$4)0$,
Important Safety Instructions
! Read these instructions.
@ Keep these instructions.
# Heed all warnings.
$ Follow all instructions.
% Do not use this apparatus near water.
This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.
^ Clean only with dry cloth.
& Do not block any ventilation openings.
Install only in accordance with the manufacturer’s instructions.
* Do not install near any heat sources such
as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
( This apparatus shall be connected to
a mains socket outlet with a protective earthing connection. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
BL Protect the power cord from being
walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
BM Only use attachments/accessories
specified by the manufacturer.
BN Use only with the cart, stand,
tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
BO Unplug this apparatus during lightning
storms or when unused for long periods of time.
BP Refer all servicing to qualified service
personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug cord is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Note: This equipm ent has bee n test ed and foun d to comply with the limits for a Clas s B digital devic e, pursuant to part 15 of th e FCC Rules. These limi ts are desig ned to provi de reasonab le prot ection agains t harmful i nterference in a residen tial instal lation. Thi s equipment genera tes, uses a nd can radi ate ra dio frequenc y energy an d, if not instal led and use d in accorda nce with th e instructi ons, may ca use harmfu l interferen ce to radio communicat ions. Howev er, there is no guaran tee that in terference w ill not occ ur in a par ticular ins tallat ion. If this e quipment do es cause ha rmful interference to radio o r televisio n recepti on, which c an be deter mined by tu rning the equipm ent off and on, the user is encouraged to try to correct the interference by one or more of the follow ing measures :
Reor ient or relo cate the rec eiving ant enna.
Incre ase the sep aration bet ween the equ ipment and receiver.
Conn ect the equ ipment into an ou tlet on a c ircuit diffe rent fro m that to w hich the rece iver is con nected.
Cons ult the dea ler or an e xperie nced rad io/TV techn ician for h elp.
Modifi cations not expressly a pproved by t he manufact urer could v oid the us ers auth ority to op erate the e quipme nt under FC C rules.
Cet ap pariel nume rique de la class e B respecte toutes les Exigences du Reglement sur le materiel brouilleur du Canada.
What Ships in the Box
An RC-6000 hardware device.
A 25-foot 25-pin D-sub cable.
Four rubber stick-on feet.
This Quick Start Guide.
What You Need to Provide
An AirTools 6100 Broadcast Audio Delay.
Getting Help
If you have questions beyond the scope of this Quick Start Guide, please download the complete User’s Guide from the Symetrix website or contact our Customer Support Group in the following ways:
Tel : +1.425.778.7728 8:00 am to 4:30 pm Monday through Friday, Pacific Time Web: http://www.symetrix.co Email:
support@symetrix.co
2
QUICK START GUIDE: RC-6000 Remote Control
Introduction and Front Panel
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
Introduction
The AirTools RC-6000 is an accessory remote control for the 6000 and 6100 Broadcast Audio Delays. The RC- 6000 Remote Control duplicates EXIT, START, COUGH and DUMP buttons found on the front panel of
the AirTools 6000 and 6100. It also features LED indiction of the delay’s current status including INACTIVE, ACTIVE, HALF delay memory built and FULL delay memory built.
Mechanical Data
ITEM DESCRIPTION DETAILS
Space Required WDH: 18.16 cm x 9.78 cm x 3.81 cm / 7.15 in x 3.85 in x 1.5 in.
Depth does not include connector allowance.
Allow at least 1 inch additional clearance for rear panel connec- tions. Additional depth may be required depending upon your specific wiring and connections.
Electrical N/A Power comes from the 6000 or 6100 via the included cable.
Venti la ti on Maximum recommended ambien t operating temperature is 30
C / 86 F.
Ventilation should not be impeded by covering the unit with items such as newspapers, tablecloths, curtains, etc.
Weight 0.24 kg / 0.52 lbs.
FRONT PANEL
ITEM DESCRIPTION DETAILS
INACTIVE Red LED Indicates that the current delay is fully exited (exactly 0.0 seconds) and the status of the delay is
“DELAY REMOVED”.
ACTIVE Red LED Indicates that some amount of delay is currently built and the delay is currently in some mode of opera-
tion.
HALF Red LED Indicates that at least half of the currently set amount of delay has been achieved.
FULL Red LED Indicates that the full amount of the currently set amount of delay has been achieved.
EXIT Momentary amber lighted switch Mirrors the status and function of the EXIT button on the front of the delay. The button flashes to
indicate that the delay is “REDUCING DELAY TIME”.
START Momentary green lighted switch Mirrors the status and function of the START button on the front of the delay. The button flashes to
indicate that the delay is “ADDING DELAY TIME”.
COUGH Momentary white lighted switch Mirrors the status and function of the COUGH button on the front of the delay. The button lights while
the button is pressed to indicate that the delay is “WAITING FOR RELEASE”.
DUMP Momentary red lighted switch Mirrors the status and function of the DUMP button on the front of the delay. The button lights while the
button is pressed.
INACTIVE ACTIVE HALF FULL
RC-6000
REMOTE CONTROL
EXIT
COUGH
START
DUMP
Loading...
+ 2 hidden pages