Symetrix 6100 User Manual

1
QUICK START GUIDE: 6100 Broadcast Audio Delay
Safety
G The lightning flash with arrowhead
symbol within an equilateral triangle is intended to alert the user of the presence of uninsulated “dangerous voltage” within the product’s enclosure that may be of sufficient magnitude to constitute a risk of electric shock to persons. The exclamation point within an equilateral triangle is intended to alert the user of the presence of important operating and maintenance (servicing) instructions in the literature accompanying the product (i.e. this Quick Start Guide).
G CAUTION: To prevent electric shock,
do not use the polarized plug supplied with the device with any extension cord, receptacle, or other outlet unless the prongs can be fully inserted.
G Power Source: This Symetrix hardware
uses a universal input supply that automatically adjusts to the applied voltage. Ensure that your AC mains voltage is somewhere between 100-240 VAC, 50-60 Hz. Use only the power cord and connector specified for the product and your operating locale. A protective ground connection, by way of the grounding conductor in the power cord, is essential for safe operation. The appliance inlet and coupler shall remain readily operable once the apparatus has been installed.
G Lithium Battery Caution: Observe the
correct polarity when changing the lithium battery. There is a danger of explosion if battery is incorrectly replaced. Replace only with the same or equivalent type. Dispose of used batteries according to local disposal requirements.
G User Serviceable Parts: There are no
user serviceable parts inside this Symetrix product. In case of failure, customers inside the U.S. should refer all servicing to the Symetrix factory. Customers outside the U.S. should refer all servicing to an authorized Symetrix distributor. Distributor contact information is available online at: http://www.symetrix.co.
"7*4
/&1"40673*3
*MOFTFUSPVWFBMJOUFSJFVSBVDVOFQJFDFQPVSWBOUFOUSFSFQBSÊFMVTBHFS
4&&08/&34."/6"-70*3$")*&3%*/4536$5*0/4
4BESFTTFSBVOSFQBSBUFVSDPNQÊUFOU
3*426&%&$)0$&-&$53*26&
/PVTFSTFSWJDFBCMFQBSUTJOTJEF3FGFSTFSWJDJOHUPRVBMJGJFETFSWJDFQFSTPOOFM
$"65*0/
8"3/*/(
503&%6$&5)&3*4,0''*3&03 &-&$53*$4)0$,%0/05&9104&
5)*4&26*1.&/5503"*/03.0*4563&
%0/0501&/
3*4,0'&-&$53*$4)0$,
Important Safety Instructions
! Read these instructions.
@ Keep these instructions.
# Heed all warnings.
$ Follow all instructions.
% Do not use this apparatus near water.
This apparatus shall not be exposed to dripping or splashing and no objects filled with liquids, such as vases, shall be placed on the apparatus.
^ Clean only with dry cloth.
& Do not block any ventilation openings.
Install only in accordance with the manufacturer’s instructions.
* Do not install near any heat sources such
as radiators, heat registers, stoves, or other apparatus (including amplifiers) that produce heat.
( This apparatus shall be connected to
a mains socket outlet with a protective earthing connection. Do not defeat the safety purpose of the polarized or grounding-type plug. A polarized plug has two blades with one wider than the other. A grounding type plug has two blades and a third grounding prong. The wide blade or the third prong are provided for your safety. If the provided plug does not fit into your outlet, consult an electrician for replacement of the obsolete outlet.
BL Protect the power cord from being
walked on or pinched particularly at plugs, convenience receptacles, and the point where they exit from the apparatus.
BM Only use attachments/accessories
specified by the manufacturer.
BN Use only with the cart, stand,
tripod, bracket, or table specified by the manufacturer, or sold with the apparatus. When a cart is used, use caution when moving the cart/apparatus combination to avoid injury from tip-over.
BO Unplug this apparatus during lightning
storms or when unused for long periods of time.
BP Refer all servicing to qualified service
personnel. Servicing is required when the apparatus has been damaged in any way, such as power-supply cord or plug cord is damaged, liquid has been spilled or objects have fallen into the apparatus, the apparatus has been exposed to rain or moisture, does not operate normally, or has been dropped.
Note: This equipm ent has bee n test ed and foun d to comply with the limits for a Clas s B digital devic e, pursuant to part 15 of th e FCC Rules. These limi ts are desig ned to provi de reasonab le prot ection agains t harmful i nterference in a residen tial instal lation. Thi s equipm ent generat es, uses an d can radiate rad io frequency energy and, i f not insta lled and us ed in accordance w ith the ins tructions, may ca use harmful interferenc e to radio communicati ons. Howeve r, there i s no guaran tee that in terference w ill not occ ur in a par ticular instal lation. If this equipm ent do es cause ha rmful inter ference to radio or televisi on reception , which can be determi ned by tur ning t he equipm ent off and on, the use r is encour aged to try to correct the interf erence by on e or more of the follow ing measure s:
Reor ient or relo cate the rec eiving ant enna.
Incre ase the sep aration bet ween the equ ipment and receiver.
Conn ect the equ ipment into an ou tlet on a c ircuit diffe rent fro m that to w hich the rece iver is con nected.
Cons ult the dea ler or an e xperie nced rad io/TV techn ician for h elp.
Modifi cations not expressly a pproved by t he manufact urer could v oid the us ers auth ority to op erate the e quipme nt under FC C rules.
Cet ap pariel nume rique de la class e B respecte toutes les Exigences du Reglement sur le materiel brouilleur du Canada.
What Ships in the Box
A 6100 hardware device.
A detachable power cord.
This Quick Start Guide.
Getting Help
If you have questions beyond the scope of this Quick Start Guide, please download the complete User’s Guide from the Symetrix website or contact our Customer Support Group in the following ways:
Te l: +1.425.778.7728 8:00 am to 4:30 pm Monday through Friday, Pacific Time Web: http://www.symetrix.co Email:
support@symetrix.co
QUICK START GUIDE: 6100 Broadcast Audio Delay
MENU OPTION DESCRIPTION
SIGNAL INPUT SOURCE ANALOG or AES/EBU
NOMINAL INPUT LEVEL -10 dBu
NOMINAL OUTPUT LEVEL -10 dBu
DIGITAL INPUT SYNC INTERNAL 48KHZ
DELAY TIME 0.0 to 40.0 SECONDS
DUMP LENGTH FIFTH
ALGORITHM GAP DETECT Waits for ga ps or p auses i n speec h and then sp lices a udio. M inimal delay artifac ts.
DELAY RATIO 10:1 to 40:1 Ratio controls the balance of delay build/exit speed vs. overall audio quality.
BARGRAPH MODE PRE DELAY
AUTOMATION MODE SWITCH CONTACTS DLYD
AUTOMATION TRIM EARLY: 300 mS
TC89 OUTPUT DELAY 0.0 to 60.0 SECONDS
REAR SERIAL PORT RS-232 (DB9)
SERIAL PORT BAUD 1200
UNIT NUMBER ID: (1-255) Sets the RS-485 bus address.
+0 dBu +4 dBu +8 dBu
+0 dBu +4 dBu +8 dBu
WORD CLOCK AES/EBU
(in 0.1 second increments)
QUARTER THIRD HALF WHOLE
GAP DETECT & CATCH UP If gaps do not naturally occur then splicing is forced. Some audible splice artifacts.
CONTINUOUS Continuously fo rces splicing regardless of program content. Some audible splic e
PITCH SHIFT Uses gradual, subtle pitch shifting instead of splicing to increase or decrease delay.
POST DELAY
RS232 DELAYED
EARLY: 270 mS EARLY: 240 mS EARLY: 210 mS EARLY: 180 mS EARLY: 150 mS EARLY: 120 mS
EARLY: 90 mS EARLY: 60 mS EARLY: 30 mS
CURRENT DELAY
LATE: 30 mS LATE: 60 mS
LATE: 90 mS LATE: 120 mS LATE: 150 mS LATE: 180 mS LATE: 210 mS LATE: 240 mS LATE: 270 mS LATE: 300 mS
(in 0.5 second increments)
RS-485 (3 PIN EURO)
2400 4800
9600 19200 38400
Operations: Menu
Very fast delay build or exit times with speech only program when known maximu m build and exit times are not required.
Use for buildin g and exiting delay with mus ic + speech when known maxim um build and exit times are required.
artifacts.
Use for buildin g and exiting delay with mus ic only when known maximum b uild and exit times are required.
Use with music or music + speech when minim al artifacts are required. Build and exit times are predictable.
(10:1 = fastest, 40:1 = best quality)
Sets t he automati on delay mod e for the u nit. Either the contac t closures o n the AUTOMATIO N rear panel D-sub conn ector or th e RS-232 co nnector may be delaye d, not both . In RS-232 delay mode, any comman ds entering the unit o n the RS-232 port will be delayed b y the amoun t of current delay and then sent b ack out th e RS-232 po rt. The RS-2 32 delay me mory is lim ited to 500 characters at any on e time. Dat a input beyo nd this lim it will be silently di scarded. If the device sendin g RS-232 au tomation dat a is differe nt than the device rece iving RS-23 2 automa tion data, a custom cab le may be r equired. Ref er to the W iring and P inout section for details.
Adjusts the automation events to exit the delay early, on time, or late in relation to the au dio. This t rim is appli ed to RS-23 2 data or c ontact clos ures dependi ng upon AUTOMATION MODE as set above.
Applie s an additi onal fixed d elay to the TC89 outpu t so that c ertain cons tant system delays can be accounted for such as encoders or satellite transmission.
Select which communications interface to use.
Sets the baud rate for the selected serial port.
6408 216th Street SW | Mountlake Terrace, WA 98043 USA
T +1.425.778.7728 F +1.425.778.7727 | www.symetrix.co
2
Loading...