Symcom PC-XXX-LLC-CZ Catalog Page

Pump Controller
The PC-xxx-LLC-CZ is a liquid level control relay used to control conductive liquid pumping operations in a pump-up or pump-down application. The unit comes in two different voltage ranges. The model PC-100-LLC-CZ is for 95-120VAC applications and the model PC-200­LLC-CZ is for 190-240VAC applications.
Model PC-XXX-LLC-CZ
Features:
One unit serves pump-up and pump-down applications
Adjustable sensitivity knob (4.7 to 100K ohms)
Debounce time delay (2 seconds)
Single or dual probe inputs (+ common
reference)
Compatible with Crouzet’s PNR & PNRU series liquid level control
LED indicator
UL508 listed
CE marked
8-pin plug in; DIN rail or surface mount
5-year warranty
Made in the USA
The unit has an adjustable sensitivity knob (4.7-100K ohms) that is set according to the resistance level at which you want the probes (sold separately) to sense the conductive liquid. The unit has a built­in debounce time delay that prevents the relay from energizing if the probe resistance momentarily goes above or below the sensitivity setpoint (due to liquid splashing in the tank).
The unit operates its internal relay based on inputs from a high and low probe and a common reference (when a conductive tank is used) or common probe (when a non-conductive tank is used).
to run the pump and ll the tank. When the liquid level rises and the
high probe resistance decreases below the sensitivity setpoint, the relay de-energizes to stop the pump.
to run the pump and empty the tank. When the liquid level drops and
The unit can also be congured to work with a single probe input and
a common reference (or common probe).
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
customerservice@symcom.com / technicalsupport@symcom.com
Rev. 1009
Specications
Functional Characteristics
Debounce Time Delay Probe Sensitivity
Input Characteristics
Supply Voltage PC-100-LLC-CZ PC-200-LLC-CZ Frequency Probe Sense Voltage
Output Characteristics
Output Contact Rating Pilot Duty General Purpose
General Characteristics
Ambient Operating Temperature Maximum Input Power Relative Humidity Terminal Torque
Wire Gauge
Standards Passed Electrostatic Discharge (ESD) Radio Frequency Immunity (RFI), Radiated Fast Transient Burst Surge Immunity IEC
ANSI/IEEE
Hi-potential Test Safety Marks UL listed (OT08 octal socket required) CE Dimensions
Weight
Enclosure Mounting Method
2 second
4.7k to 100k Adjustable
95-120VAC 190-240VAC 50/60 Hz (note: 50Hz will increase all delay timers by 20%) 5vdc pulsed
480VA @ 240VAC 10A @ 240VAC
-40o to 70o C (-40o to 158o F)
5 W
10-95%, non-condensing per IEC 68-2-3 12 in.-lbs.
12-22 AWG Solid or stranded
IEC 61000-4-2, Level 3, 6kV contact, 8kV air 150MHz, 10V/m IEC 61000-4-4, Level 3, 2 kV input power and controls
IEC 61000-4-5, Level 4, 4kV line-to-line; Level 4, 4kV line-to­ground; Level 2, 1kV probe inputs-to-ground
C62.41 Surge and Ring Wave Compliance to a level of 6kV
line-to-line Meets UL508 (2 x rated V + 1000V for 1 minute)
UL508 (File #E68520) IEC 60947-6-2
1.750” H x 2.375” W x 4.125” D (with socket)
9 oz. Polycarbonate Plugs into 8-Pin OT08 Socket; DIN Rail or surface mount
Enclosure Dimensions
2.375”
(60.331)
BOTTOM
1.75”
(44.55)
4.125”
(104.65)
How to order: Part Number: PC-100-LLC-CZ
PC-200-LLC-CZ
SIDE
WITH OT08* SOCKET
*The OT08 octal socket is 35mm DIN rail compatible. The use of an OT08 octal socket is required to qualify as a UL listed device.
Auxiliary Products: OT08-PC (8-pin octal socket)
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
customerservice@symcom.com / technicalsupport@symcom.com
Rev. 1009
Loading...