Symcom CP-5 Catalog Page

2880 North Plaza Drive • Rapid City, SD 57702 (800) 843-8848 • (605) 348-5580 • FAX (605) 348-5685 www.symcominc.com • email: sales@symcominc.com
Features
Adjustable 0 -10 minute trip delay provides flexibility in applications.
Bicolor LED indicator light is green in normal conditions and red during trip conditions.
Adjustable trip level of 0-5A.
10A @ 240VAC general purpose relay switches loads on 115 and 240V applications.
Microcontroller based design provides better accuracy and higher reliability than analog designs.
470VA @ 600 VAC relay switches higher voltage loads on 480V systems.
Three choices of input voltage ranges provide the versatility needed to handle global applications.
Model CP-5
Engineered
Protection
Microcontroller
Based
Protects 3-Phase motors from:
•Undercurrent conditions
Standard Features:
•UL and cUL listed
•5 year warranty
•Made in USA
•Adjustable 0-5A trip level
•Adjustable 0-10 min trip delay
•Surface or DIN rail mountable
Model CP-5 is an undercurrent monitor designed to monitor one leg of a three phase system. It is commonly used as a tower monitor on center pivot irrigation systems to detect a stalled center pivot.
The CP-5 has both an adjustable trip level and an adjustable trip delay timer. When the current is sensed, the Model CP-5 activates its output relay, thus starting the motor/pump. When the current in the monitored power line falls below the user-selectable trip point, the output relay then goes through the trip delay timer before finally deactivating the relay.
6/04
2880 North Plaza Drive • Rapid City, SD 57702 (800) 843-8848 • (605) 348-5580 • FAX (605) 348-5685 www.symcominc.com • email: sales@symcominc.com
Model CP-5
SymCom warrants its microcontroller based products against defects in material or workmanship for a period of five (5) years from the date of manufacture. All other products manufactured by SymCom shall be warranted against defects in material and workmanship for a period of two (2) years from the date of manufacture. For complete information on warranty, liability, terms, returns, and cancellations, please refer to the SymCom Terms and Conditions of Sale document.
0.060" (1.52)
2.160" (54.86)
2.973" (75.51)
STATUS
OK
GREEN
STATUS
TRIPPED
RED
TRIP DELAY BLINK RED
TRIP DELAY (MIN)
Pilot Duty Rating 470VA at 600VAC
TRIP AMPS
1
05
4
23
010
28
46
NC C
CT1 CT2
L1 L2
460 VAC
MODEL CP - 5
TOWER MONITOR
Rapid City, SD
IND. CONT. EQ.
LISTED
784X
3.780" (96.01)
2.656" (67.46)
D. 0.375"
(9.53)
4.500" (114.30)
5.250" (133.35)
L1
L1
L2
L2
L3
CT1
PUMP
CONTROL
POWER
CT2
MAG.
CENTER
PIVOT PANEL
COIL
STOP
OFF
M
HAND
AUTO
START
OLs
6/04
Specifications
Operating Points
Special Options
Specifications
Input Voltage . . . . . . . . . . . . . .115, 240, 480 VAC Order # CP-5-115
Frequency . . . . . . . . . . . . . . . .50* or 60 Hz Order # CP-5-460
Operating Points
•Trip Level . . . . . . . . . . . . . . . . .0 - 5 Amps
•Trip Delay . . . . . . . . . . . . . . . . .0 to 10 minutes
•Restart . . . . . . . . . . . . . . . . . . .1.0 second
Output Relay (SPDT)
•Pilot Duty Contact Rating . . . . .470 VA @ 600 VAC (480V unit)
. . . . . . . . . . . . . . . . . . . . . . . . .480 VA @ 240 VAC (120 & 240V units)
Weight . . . . . . . . . . . . . . . . . . .14 oz.
*Note: 50 Hz will increase all delay timers by 20%.