Features
Bicolor LED indicator light is green in normal conditions and red dur­ing trip conditions.
10A @ 240 VAC General Purpose Relay can switch most loads.
Microcontroller based provides better accuracy and higher reliability than analog designs.
Transient protected to meet IEC 1000-4-5:1995 Standards and stand up under tough conditions.
Model 50R
Single Phase
Voltage Monitor
Engineered
Protection
Microcontroller
Based
Protects Single-Phase motors from:
Low Voltage
Optional High Voltage
Additional features:
UL and cUL listed
5 year Warranty
Made in USA
Surface mount with
optional DIN Rail Mountability
Optional Manual 2-300 sec. Variable Restart
Delay
Optional 2-30 sec. Trip Delay
Model 50R Single Phase Voltage Monitor has a voltage sensing circuit which constantly monitors the single phase power for a low voltage condition. Single phase motors on fans, compressors, air conditioners, heat pumps, well pumps, sump pumps, and small
conveyor motors are all applicable to the Model 50R.
When a harmful condition is detected, the MotorSaver's output relay is deactivated after a specified trip delay. The output relay reacti­vates after power line conditions return to an acceptable level for a specified amount of time (Restart Delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions.
6/02
2880 North Plaza Drive Rapid City, SD 57702 (800) 843-8848 (605) 348-5580 FAX (605) 348-5685 http://www.symcominc.com email: sales@symcominc.com
6/02
SymCom warrants its microprocessor based products against defects in material or workmanship for a period of five (5) years from the date of manufacture. All other products manufactured by SymCom shall be warranted against defects in material and workmanship for a period of two (2) years from the date of manufacture. For complete information on warranty, liability, terms, returns, and cancellations, please refer to the SymCom Terms and Conditions of Sale document.
Model 50R
MS50R
Single Phase
Voltage Monitor
LINE VOLTAGE
ADJUST
220208
200
190
(VAC)
GEN. PURPOSE RATING
SymCom, Inc.
L1 L2
190-240 VAC, 1fl, 50/60 HZ
230
240
10 A at 240 VAC
PILOT DUTY RATING
480 VA at 240 VAC
TOP
MODEL 50R
P/N- MS50R - 200
RUN
LIGHT
C
IND. CONT. EQ
U
LISTED
RESTART
DELAY
150
70
2
220
300
MAN
(SECONDS)
Rapid City, SD
IND. CONT. EQ
U
784X
784X
L
L
¤
¤
LISTED
2.900" (73.66)
Specifications
4.030" (102.36)
4.500" (114.30)
Operating Points
5.250" (133.35)
Special Options
Specifications Order # Line Voltage Ranges 50R-100-2
100 V Model...........................................95 - 120 50R-200-2-9
200 V Model...........................................190 - 240 50R-200-2
400 V Model* ...................................... ..380 - 480 50R-200-3
*Comes standard with 470V
Frequency .................................. ....50* or 60 Hz
Low Voltage 50R-400-2
Trip (% of set point) ..........................................90% 50R-400-3
Reset (% of set point) ......................................93%
Delay Time (Nominal)
T
rip ....................................................................2 seconds
Restart (low voltage) ........................................2 seconds
Restart (complete power loss)..........................2 seconds
Output
Pilot Duty (SPDT) ............................................10 A
Transient Protection (Internal) ..........................IEC 1000-4-5; 1995 ±6 kv
eight ..............................................................1 lb.
W Special Options
Variable Time Delay Restart ............................2 - 300 seconds w/manual reset
Variable Trip Delay............................................2 - 30 seconds
Manual Reset....................................................Standard w/Adj. Restart Delay
High Voltage Operating Points
Trip (% of Set point)............................110%
Reset (% of Set point) ........................107%
For special operating points, contact the factory.
A@600VAC relay. 50R-200-9
50R-400-2-9
WIRING DIAGRAM FOR MODEL 50R
WITH MOTOR CONTROL
General Purpose
or 480 VA @ 240 VAC
WIRING DIAGRAM FOR MODEL 50R
WITH ALARM CONTROL
SIDE
MS50R
0.150" (3.81)
2.163"
(54.94)
.375" (9.53)
2.913"
(73.99)
*Note: 50Hz will increase all delay timers by 20%