Single-Phase Voltage Monitor
Model 201-XXX-SP
Features:
• Low voltage protection
• Low & high voltage protection model
available
• Diagnostic LED
• UL508 listed
• CE Marked
• 8-pin plug in; DIN rail or surface mount
• 5-year warranty
• Made in USA
The Model 201-xxx-SP is an 8-pin octal base plug-in voltage monitor designed to protect single-phase motors regardless of size. It
can be used on 95-120VAC (201-100-SP) or 190-240VAC (201-200SP) motors to prevent damage caused by low voltage. High voltage
detection is included on the 201-200-SP-T-9 model.
The unique microcontroller-based voltage and voltage-sensing circuit constantly monitors the voltage to detect harmful power line
conditions. When a harmful condition is detected, the MotorSaver’s
output relay is deactivated after a specied trip delay. The output
relay reactivates after power line conditions return to an acceptable
level and a specied amount of time has elapsed (restart delay).
The trip delay prevents nuisance tripping due to rapidly uctuat-
ing power line conditions.
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
customerservice@symcom.com / technicalsupport@symcom.com
Rev. 0909

Specications
Functional Specications
Low Voltage (% of setpoint)
Trip
Reset
High Voltage
Trip (% of setpoint)
Reset (% of setpoint)
Trip Delay Time
Low Voltage
High Voltage
Restart Delay Time
After a fault or complete power loss
Input Characteristics
Supply Voltage
201-100-SP
201-200-SP
201-200-SP-T-9
Frequency
Output Characteristics
Output Contact Rating-SPDT
Pilot Duty
General Purpose
General Characteristics
Ambients Operating Temperature
Maximum Input Power
Relative Humidity
Terminal Torque
Wire Gauge
Standards Passed
Electrostatic Discharge (ESD)
Radio Frequency Immunity (RFI), Radiated
Fast Transient Burst
Surge Immunity
IEC
ANSI/IEEE
Hi-potential Test
Safety Marks
UL Listed (OT08 octal socket required)
CE
Dimensions
Weight
Enclosure
Mounting Methods
90%
93%
110% (-9 unit only)
107% (-9 unit only)
4 seconds
4 seconds (-9 unit only)
2 seconds
95-120VAC
190-240VAC
190-240VAC
50/60Hz (note: 50Hz will increase all delay timers by 20%)
480VA@240VAC
10A@240VAC
-40o to 70o C (-40o to 158o F)
5 W
10-95%, non-condensing per IEC 68-2-3
12 in.-lb.
12-22 AWG Solid or stranded
IEC 61000-4-2, Level 3, 6kV contact, 8kV air
150MHz, 10V/m
IEC 61000-4-4, Level 3, 3.5 kV input power and controls
IEC 61000-4-5, Level 3, 4kV line-to-line; Level 4, 4kV line-to-ground
C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line
Meets UL508 (2 x rated V + 1000V for 1 minute)
UL508 (File #E68520)
IEC 60947-6-2
1.75”H x 2.375”W x 4.125”D (with socket)
9 oz.
Polycarbonate
Plugs into 8-Pin OT08 Socket; DIN rail or surface mount
Enclosure Dimensions
2.375”
(60.331)
BOTTOM
1.75”
(44.55)
4.125”
(104.65)
How to order:
Part Number: 201-100-SP
201-200-SP
201-200-SP-T-9
SIDE
WITH OT08* SOCKET
Auxiliary Products:
CT-OT08-PC (8-pin octal socket)
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
customerservice@symcom.com / technicalsupport@symcom.com
Rev. 0909