Single-Phase Voltage Monitor
Model 201-XXX-SP
Features:
Low voltage protection
Low & high voltage protection model
available
Diagnostic LED
UL508 listed
CE Marked
8-pin plug in; DIN rail or surface mount
5-year warranty
Made in USA
The Model 201-xxx-SP is an 8-pin octal base plug-in voltage moni­tor designed to protect single-phase motors regardless of size. It can be used on 95-120VAC (201-100-SP) or 190-240VAC (201-200­SP) motors to prevent damage caused by low voltage. High voltage detection is included on the 201-200-SP-T-9 model.
The unique microcontroller-based voltage and voltage-sensing cir­cuit constantly monitors the voltage to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s
output relay is deactivated after a specied trip delay. The output
relay reactivates after power line conditions return to an acceptable
level and a specied amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly uctuat-
ing power line conditions.
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685
customerservice@symcom.com / technicalsupport@symcom.com
Rev. 0909
Page 2
Specications
Functional Specications
Low Voltage (% of setpoint) Trip Reset High Voltage Trip (% of setpoint) Reset (% of setpoint) Trip Delay Time Low Voltage High Voltage Restart Delay Time After a fault or complete power loss
Input Characteristics
Supply Voltage 201-100-SP 201-200-SP 201-200-SP-T-9 Frequency
Output Characteristics
Output Contact Rating-SPDT Pilot Duty General Purpose
General Characteristics
Ambients Operating Temperature Maximum Input Power Relative Humidity Terminal Torque Wire Gauge Standards Passed Electrostatic Discharge (ESD) Radio Frequency Immunity (RFI), Radiated Fast Transient Burst Surge Immunity IEC ANSI/IEEE Hi-potential Test Safety Marks UL Listed (OT08 octal socket required) CE Dimensions Weight Enclosure Mounting Methods
90% 93%
110% (-9 unit only) 107% (-9 unit only)
4 seconds 4 seconds (-9 unit only)
2 seconds
95-120VAC 190-240VAC 190-240VAC 50/60Hz (note: 50Hz will increase all delay timers by 20%)
480VA@240VAC 10A@240VAC
-40o to 70o C (-40o to 158o F) 5 W 10-95%, non-condensing per IEC 68-2-3 12 in.-lb. 12-22 AWG Solid or stranded
IEC 61000-4-2, Level 3, 6kV contact, 8kV air 150MHz, 10V/m IEC 61000-4-4, Level 3, 3.5 kV input power and controls
IEC 61000-4-5, Level 3, 4kV line-to-line; Level 4, 4kV line-to-ground C62.41 Surge and Ring Wave Compliance to a level of 6kV line-to-line Meets UL508 (2 x rated V + 1000V for 1 minute)
UL508 (File #E68520) IEC 60947-6-2
1.75”H x 2.375”W x 4.125”D (with socket) 9 oz. Polycarbonate Plugs into 8-Pin OT08 Socket; DIN rail or surface mount
Enclosure Dimensions
2.375”
(60.331)
BOTTOM
1.75”
(44.55)
4.125”
(104.65)
How to order: Part Number: 201-100-SP
201-200-SP 201-200-SP-T-9
SIDE
WITH OT08* SOCKET
Auxiliary Products: CT-OT08-PC (8-pin octal socket)
(605) 348.5580 / (800) 843.8848 / Fax (605) 348.5685