Symbol LS 1220 Quick Reference Manual

LS 1220
Quick Reference • Guide utilisateur • Kurzübersicht • Guida rapida • Guía rap­ida • Quic k Refe rence • Guid e util isate ur
• Kurzübersicht • Guida rapida • Guía rapida • Quick Reference • Guide utili­sateur • Kurzüber sicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisat eur • K urz übersic ht • Guid a ra pi­da • Guía rapida • Quick Reference • Guide u tili sat eur • Kurz über sicht • Gui­da rapi da • Guía rapida • Quick Refer­ence • Guide utilisateur • Kurzübersicht • Guida rap ida • Gu ía rap ida • Q uick R ef­erence • Guide utilisateur • Kur züber­sicht • Guida rapida • Guía rap ida • Quick Reference • Guide utilisa teur • Kurzübersicht • Guida rapida • Guía rap­ida • Quic k Refe rence • Guid e util isate ur
• Kurzübersicht • Guida rapida • Guía rapida • Quick Ref er ence • Guide utili­sateur • Kurzüber sicht • Guida rapida • Guía rapida • Quick Reference • Guide utilisat eur • K urz übersic ht • Guid a ra pi­da • Guía rapida • Quick Reference •
Quick Refere nce
© 2001 SYMBOL TECHNOL OGIES, IN C .
Symbol reserves the right to make changes to any product to improve reliability, function, or design. Symbol does not assume any product liability arising out of, or in connection with, the application or use of any product, circuit, or application described herein. No license is granted, either expressly or by implication, estoppel, or otherwise under any pate nt right or patent, covering or relating to any combination, system, apparatus, machine, material, method, or process in which Symbol products might be used. An implied license exists only for equipment, circuits, and subsystems contained in Symb ol p rodu cts. Symbol and the Symbol logo are registered trademark s of Symbol T echnologies, Inc. Other product names mentioned in this manual may be trademarks or registered trademarks of their respective companies and are hereby acknowledged. Symbol Technologies, Inc.
One Symbol Plaza Holtsville, N.Y . 11742-1300
http://www.symbol.com
Patents
This product is covered by one or m ore of the following U.S. and foreign Patents: U.S. Patent No. 4,460,120; 4,496,831; 4,593,186; 4,603,262; 4,607,156 ; 4,652,750; 4,673,805 ;
4,736,095; 4,758,717; 4,816,66 0; 4,84 5,350; 4,896,02 6; 4,897,532; 4,923,281; 4,933,538; 4,992,717; 5,015,833; 5,017,76 5; 5,02 1,641; 5,029,18 3; 5,047,617; 5,103,461; 5,113,445; 5,130,520; 5,140,144; 5,142,55 0; 5,14 9,950; 5,157,68 7; 5,168,148; 5,168,149; 5,180,904; 5,216,232; 5,229,591; 5,230,08 8; 5,23 5,167; 5,243,65 5; 5,247,162; 5,250,791; 5,250,792; 5,260,553; 5,262,627; 5,262,62 8; 5,26 6,787; 5,278,39 8; 5,280,162; 5,280,163; 5,280,164; 5,280,498; 5,304,786; 5,304,78 8; 5,30 6,900; 5,321,24 6; 5,324,924; 5,337,361; 5,367,151; 5,373,148; 5,378,882; 5,396,05 3; 5,39 6,055; 5,399,84 6; 5,408,081; 5,410,139; 5,410,140; 5,412,198; 5,418,812; 5,420,41 1; 5,43 6,440; 5,444,23 1; 5,449,891; 5,449,893; 5,468,949; 5,471,042; 5,478,998; 5,479,00 0; 5,47 9,002; 5,479,44 1; 5,504,322; 5,519,577; 5,528,621; 5,532,469; 5,543,610; 5,545,88 9; 5,55 2,592; 5,557,09 3; 5,578,810; 5,581,070; 5,589,679; 5,589,680; 5,608,202; 5,612,53 1; 5,61 9,028; 5,627,35 9; 5,637,852; 5,664,229; 5,668,803; 5,675,139; 5,693,929; 5,698,83 5; 5,70 5,800; 5,714,74 6; 5,723,851; 5,734,152; 5,734,153; 5,742,043; 5,745,794; 5,754,58 7; 5,76 2,516; 5,763,86 3; 5,767,500; 5,789,728; 5,789,731; 5,808,287; 5,811,785; 5,811,78 7; 5,81 5,811; 5,821,51 9; 5,821,520; 5,823,812; 5,828,050; 5,850,078; 5,861,615; 5,874,72 0; 5,87 5,415; 5,900,61 7; 5,902,989; 5,907,146; 5,912,450; 5,914,478; 5,917,173; 5,920,05 9; 5,92 3,025 5,929,420; 5,945,658; 5,945,659; 5,946,194; 5,959,285; 6,002,918; 6,021,94 7; 6,03 6,098; 6,047,89 2; 6,050,491; 6,053,413; 6,056,200; 6,065,678; 6,067,297; 6,068,19 0; 6,08 2,621; 6,084,52 8; 6,088,482; 6,092,725; 6,101,483; 6,102,; 6,104,620; 6,114,712; 6,115,678 ; 6,119,944; 6,123,265; 6,131,81 4; 6,13 8,180; 6,142,379; 6,172,478; 6,176,42 8; 6,17 8,426; 6,186,40 0; 6,188,681; D305,885; D341,584; D344,501; D359 ,483; D3 62,453 ; D363,700; D36 3,918; D 370 ,478; D 3 83,124 ; D391,250; D405,077; D406 ,581; D4 14,171 ; D414,172; D41 8,500; D 419 ,548; D 4 23,468 ; D424,035; D430,158; D430 ,159; D4 31,562 ; D436,104. Invention No. 55,358; 62,539; 69,060; 69,187 (Ta iwan ); No. 1,601,79 6; 1,90 7,875; 1,955,26 9 (Japan). European Patent 367,2 9 9; 414,281; 367,300; 367,298; UK 2,072,832; France 81/03938; Italy 1,138,713. rev. 04/01
All rights reserved.
Quick Refere nce

Set U p

The LS 1220 can be triggered either by a software trigger command, or by an external switch. Available from Symbol is a photo detector (p/n 50-13700-025), a push button switch (p /n 25-04950 -01) and a foot switch (p/n 25-04951-0 2). If your LS 1220 came without a host cable, or if you are constructing you own external trig ge ri n g s wi tc h, con s u lt t he LS 1220 Product Reference Guide.
To connect your LS 1220:
• Plug the 25-pin D-connector into the appropriate RS-232C port o n your host te rmi nal.
• Plug the 9-pin D-connector into the LS 1220.
• If using an external switch, plug it into the female stereo c o nn e ct or on th e fl yi ng l ea d of the 9 -p i n D-connector.
• Plug the output cable from the power supply into the receptacle on the side of the 25-pin D­connector.
1
2

Set U p

• Plug the powe r supply i nto an app rop r i ate AC receptacle.
• If host powered, a separate power supply is not required.
• Check all connections to be sure they are secure.
• Program your LS 1220. Triggering option bar codes begin on page 6. Refer to the LS 1220 Programmer’s Guide for more information on selecting specific parameters.
Quick Refere nce

Scanning Made Easy

Ready

Before you use the scanner, make sur e all cable connections are secure.

Test

When you trigger the unit, the scan beam is energized for approximately 1 second. A tw o button switch is r equired to activate the aiming be am in l on g r ange models.

Scan

Make sure the bar c ode is within th e scanning range. Align the bar code and trigger the unit. The scanner has read the symbol when the green DECODE LED lights.
3
4

Aiming Tips

Scan the Entire Symbol

• The scan beam must cr oss every b ar a nd space on the symbol.
• The larger the symbol, the farther away you should hold it from the scanner.
• When th e bars on the symbol are close together, hold the symbol clos e r to the scanner.

RIGHT

012345

WRONG

Quick Refere nce
012345

Aiming Tips

Position at an Angle

Do not positi on the scanner e xactly pe r pe ndicular to the bar code being scanned. In this position, light can bounce back into the scanner’s exit window, and possibly prevent a successful decode.

Long Range

Long Range models have an aiming mode to facilitate accuracy over a longer distance. Consult the LS 1220 Product Reference Guide for more information.
5
6

Triggering Options

The LS 1220 can be energized in any of seven ways. To select a specific option, scan the associated bar code beginning on page 40.

Level

A trigger pull or external switch closure activates the laser and decode processing. The laser remains on, and decode processing continues until a trigger release, a valid decode, or th e Laser O n Tim e -out is reached.

Host

The host sends a La ser On c ommand. Th e laser remains on and decode processing occurs until a good decode, the Laser On Time-o ut is r eached, or the host s ends a Laser Off command.

Pulse

A trigger pull activates the laser and decoding processing. The laser remains on and decode processing continues until a valid decode or the Laser On Time-out is reached.

Next New Code

The LS 1220 decodes a nd transmits inf ormation, then wait s until a new cod e is dete ct ed before transm itti ng ag a in.
Quick Refere nce

Triggering Options

Continuous Level

The laser is always on. Decode processing begins with an activation and conti n ue s un ti l a good decode, the activation ceases, or the Laser O n Time-out is reach e d.

Constant Scan & Report

Laser is always on and decoding. This option is not recommended when programming the scanner with bar code menus.

Continuous Pulse

The laser is always on. Decode processing begins with an activation and continues until a good decode, or the Laser On Time-out is reached.
7
8

What If...

Nothing happens when you follow the operating instructions.

• Check the system power.
• Check for loose cable connections.
• Make sure the scanner is programmed to read the type of bar code you want to scan.
• Check the symbol to make sure it is not defaced.
• Try scanning similar symbols of the same code type.
Note: If after performing these checks the symbol still does
not sca n , cont act the te ch ni c a l pe rson in c ha rge of scanning, or call the Symbol Support Center at one of the numbers listed in the Product Reference Guide.
Quick Refere nce

Installation

Le lecteur LS 1220 peut être actionné par une commande du logiciel ou un interrupteur externe. Symbol propose un détecteur photographique (p/n 50-13700-025), un bouton poussoir (p/n 25-04950-01) et un interrupteur à pied (p/n 25-04951-02). Si votre LS 1220 est livré sans câble ou si vous construisez votre propre dispositif de déclenchement externe, reportez-vous au Guide de référence produit du LS 1220.
Pour connecter votre LS 1220 :
• Branchez le connecteur D 25 broches dans le port RS-232C correspondant sur votre terminal ordinateur central.
• Branchez le connecte ur D 9 broches sur le LS 1220.
• Si vous utilisez un interrupteur externe, raccordez-le au connecteur stéréo femelle sur la partie mobile du connecteur D 9 broches.
• Branchez le câble d’alimentation sur la prise latérale du connec teur D 25 broches.
9
10

Installation

• Branchez le câble d’alimentation sur secteur.
• Si l’ordinateur central est déjà sous tension, il est inutile d’alimenter séparément le lecteur.
• Vérifiez que tous les câbles sont correctement branchés.
• Programmez v otre L S 1220. Les codes à barre s des options de déclenchement commencent à la page
14. Reportez- vous au Guide du programmeur du LS 1220 pour de plus amples informations sur la sélection de paramètres spécifiques.
Guide utilisateur
11

La lecture en toute simplicité

Préparation

Avant d’utiliser le lecteur, vérifiez que tous les câbles sont correct ement branchés.

Test

Lorsque vous appuyez sur la gâchette du lecteur, le faisceau de lecture est activé pendant environ 1 seconde. Pour activer le faisceau de visée sur les modèles longue distance, il convient de monter une gâchette à deux positions.

Lecture

Assurez-vous que le code à barres est à portée de lecture. Alignez le code à bar re s et pres sez la gâch ette. Le déco dage est effectué lorsque LE TÉMOIN vert DE DÉCODAGE s’allume.
12

Conseils de visée

Lisez le code dans son intégralité

• Le faisceau de lecture doit recouvrir toutes les barres et tous les espaces constituant le code.
• Plus le code est large, plus vous devez l’éloigner du lecteur.
• Lorsque les barres composant le code sont rapprochées, tenez-le plus près du lecteur.

CORRECT

012345

INCORRECT

Guide utilisateur
012345
13

Conseils de visée

Angle de lecture

Ne positionnez pas le lecteur perpendiculair ement au code à barres à déc oder. Dans cette position, la lumièr e se r eflète sur la fenêtre de lecture du lecteur et risque d’empêcher le décodage.

Longue distance

Les modèles lecture longue distance sont munis d’un dispositif de visée pour améliorer la fiabilité à grande distance. Reportez-vous au Guide de référence produit pour de plus amples informations.
14

Options de déclenchement

Il existe sept manières d’activer le LS 1220. Pour sélectionner l’une d’entre elles, lisez le code à barres correspondant, à partir de la page 41.

Niveau

La pression sur la gâchette ou un interrupteur externe active le laser et le processus de décodage. Le laser reste activé et le processus de décodage se poursuit jusqu’à ce que la gâchette soit relâchée, qu’un décodage soit effectué ou que la d urée d’activation du laser soit a tteinte.

Ordinateur central

L’ordinateur central transmet une commande d’activation du laser . Le laser et le processus de décodage restent activés jusqu’à ce qu’un code soit décodé, que la durée d’activati on du l a se r soit attei n te ou qu e l’ ordin at eur central transmette une commande de désactivation du laser.

Impulsion

Le laser et le processus de décodage sont activés par un déclenchement logiciel ou un interrupteur externe. Ils restent activés jusqu’à ce qu’un code soit décodé ou que la durée d’activation du laser soit atteinte.
Guide utilisateur
Loading...
+ 36 hidden pages