www.sylvania.com
QUICKTRONIC®DALI
T8 Dimming
Professional Series
Lamp/Ballast Guide
32W T8 - OCTRON
1-lamp QTP1x32T8/DALI
2-lamp QTP2x32T8/DALI
Operates Lamp Types:
FO32
FBO32
FBO31
Key System Features
• Digital Addressable Control
• Individual control of fixtures
• Up to 16 groups
• Up to 16 scenes
• 100-1% dimming
• Programmable fade rates
• 1.0 ballast factor at full power
T8 DALI
• Universal input voltage (120/277V)
• Programmed rapid start
• QUICK 60+®lamp and ballast
warranty
• Anti-flash circuitry – turns on at
previous light level
• Operates >40kHz to reduce potential
IR interference
• Control may be wired for Class 1 or
Class 2 applications
• Wiretrap connectors
• UL, cUL, FCC
Application Information
SYLVANIA QUICKTRONIC
DALI Dimming is ideally suited for:
• All size offices
• Daylight harvesting
• Energy management
• Load shedding
• A/V presentations
• Conference rooms
• Occupancy sensors
• Creative lighting designs
For optimal dimming performance,
fluorescent lamps may require
seasoning up to 100 hours prior to
dimming to the lowest light levels.
®
SYLVANIA QUICKTRONIC DALI Dimming
combines digital control technology with
full-range continuous dimming to provide
a new level of lighting system performance.
This allows for greater flexibility and control
of the lighting environment than can be
achieved with traditional 0-10VDC dimming
systems. The communications protocol is
“DALI”, an acronym for “Digital
Addressable Lighting Interface”. This is a
worldwide standard for digital lighting
control that has been accepted by all the
leading lighting suppliers.
SYSTEM 32 DALI controls OCTRON T8
lamps over a wide (100-1%) range of light
level settings, from 1.0 ballast factor to
.01 ballast factor. Control wiring is
simplified by two polarity-free connections
that can be routed in the same raceway
as power wires.
SYSTEM 32 DALI is available in one and
two lamp models that operate at 120V or
277V input line voltage, eliminating
“wrong voltage” wiring errors and
reducing the number of models in
inventory by half.
System Information
Programmed rapid start ballasts provide
optimum starting conditions to provide
up to 100,000 switching cycles for use
on occupancy sensor and building
control system applications.
Individual addressability allows the user
to dim any particular fixture or groups
of fixtures at one time. Simple controller
programming steps allow for:
1. Fade rates, dim levels, time of day,
groups and scenes to be customized.
2. Flexibility in grouping fixtures;
(no need to re-wire fixtures when
groups need to be changed.
3. Systems are scalable and can be
expanded anytime user needs
change, without the need for costly
re-wiring. Additional fixtures are
added to groupings simply by means
of software.
Electronic T8 Fluorescent
Digital Dimming Systems
SYSTEM 32 DALI offers full rated lamp
output (1.0 ballast factor) at the maximum
light setting. Compared to “normal”
systems (0.88 ballast factor), this allows
for higher light levels when desired and
can be used to compensate for lamp
lumen depreciation. Setting the standard
for quality, SYSTEM 32 DALI is also
$ SAVINGS PER YEAR* vs LIGHT LEVEL
$25.00
$20.00
$15.00
$10.00
$ SAVINGS Per Year
$5.00
$0.00
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
When used in conjunction with appropriate controls, feedback can be obtained
on operating conditions, such as operating
hours, light-level or failed lamps. This
lamp fault-reporting feature can save
significant cost by quickly identifying the
location, especially in large facilities or in
applications where lamps are concealed
by lenses.
(FO32T8 Lamps, QUICKTRONIC DALI T8 Ballasts)
$23.20
2 Lamp Fixture
$12.00
1 Lamp Fixture
covered by our QUICK 60+
first and most comprehensive system
warranty in the industry.
Light Level
*Based on 4,000 burn hrs/yr & $0.10/kWh
SYSTEM 32 DALI lighting systems can
also be integrated with Building
Management Systems (BMS) by installing
gateways that translate between the DALI
and BMS systems. Specification of DALI
compatible gateways, controls and
ballasts ensure flawless operation of the
lighting system.
®
warranty, the
92
SPECIFICATION DATA
QTP1x32T8/UNV DALI
LAMP
Green
White
Black
Purple
Purple
DALI
DIMMING
BALLAST
1
2
3
4
Red
Red
Blue
Blue
DALI Control Leads (non-polarized)
Class 1 or Class 2 Circuit
G
N
L
LAMP 2
LAMP 1
QTP2x32T8/UNV DALI
DALI
DIMMING
BALLAST
1
2
3
4
5
6
Red
Red
Yel lo w
Yel lo w
Blue
Blue
Green
White
Black
Purple
Purple
DALI Control Leads (non-polarized)
Class 1 or Class 2 Circuit
G
N
L
Width
Height
Mounting
Length
Length
Catalog # Date Type
Project Prepared by
Comments
T8 DALI
Professional Series
Electronic DALI T8 Fluorescent Controllable Lighting Systems (120/277V)
Input Rated Ballast Input System
Item Current Lamp Lumens No. of Factor System Power Efficacy
Number Description (AMPS) Type (lm) Lamps (BF) Lumens (Watts) (lm/W) BEF
51350 QTP 1x32T8/UNV DALI 0.31/0.13 FO32XP 3000 1 1.00 3000 36 83 2.78
0.01 30 6
51352 QTP 2x32T8/UNV DALI 0.61/0.26 FO32XP 3000 2 1.00 6000 72/70 83/86 1.43
0.01 60 12
1: Ballast Efficiency Factor (BEF) = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value).
Wiring Diagrams:
Wiring: Push-in (wiretrap) connections
Use 18 AWG solid copper wire only
Performance Guide
Data shown based upon SYLVANIA
®
OCTRON
TRONIC®DALI ballasts are also
1
FO32/XP™lamps. QUICK-
compatible with other manufacturers
equivalent lamp types that meet
ANSI specifications.
Specifications
Starting Method: Programmed
Rapid Start
Circuit Type: Series
Lamp Frequency: >40kHz
Lamp CCF: <1.7
Starting Temp: 50°F (10°C) min.
Input Frequency: 50/60 Hz
THD: <10% @ full output
Power Factor: >98% @ full output
Voltage Range: ±10% of 120/277
rated voltage
UL Listed Class P, Indoor
cUL Certified
Temp. Test Point (Tc) on ballast label:
1 lamp model: 65°C max
2 lamp model: 70°C max.
All other points on ballast: 75°C max.
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
No Remote or Tandem Wiring
T8 DALI
Packaging:
Quantity: 25 pieces
Weight: 1.2 lbs each (approx.)
Dimensions:
Units L ML W H
inches 18.05 17.70 1.18 1.18
mm 458.5 449.6 30.0 30.0
Item Number 51352 QTP 2 x 32T8 / UNV DALI
QUICKTRONIC PROFESSIONAL
Number of Lamps
Specifications subject to change without notice.
Control Information
QUICKTRONIC DALI ballasts are
compatible with DALI digital
controllers available from various
manufacturers. For a list of DALI
control manufacturers, please contact
OSRAM SYLVANIA.
Refer to pages 100 & 101 for
controls information.
Control Specifications:
Two wire non-polarized control.
May be wired as Class 1 or Class 2
circuit, consult Local and National
Electrical Codes.
OSRAM SYLVANIA
National Customer
Service and Sales Center
System Type - DALI
Line Voltage (120/277V)
Primary Lamp Type (F32T8)
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com
93