Sylvania T5 PSN DATASHEET

www.sylvania.com
QUICKTRONIC®PROStart®T5 Universal Voltage
Professional Series
Lamp / Ballast Guide
28W T5 - PENTRON
1-lamp QTP1x28T5/UNV PSN or
QTP2x28T5/UNV PSN*
2-lamp QTP2x28T5/UNV PSN
Primary Lamp Type:
FP28
Also operates:
FP14, FP21, FP35
*Two lamp model can be wired for
one lamp operation.
Key System Features
• Universal voltage (120-277V)
T5 PSN
• Low-profile (0.87" High)
• QUICKSENSE®ballast technology (end-of-lamp-life sensing)
• PROStart programmed rapid start
• UL type CC rated
• 0°F (-18°C) Starting
• Operates at >40 kHz to reduce potential interference with infrared control systems
• High power factor
• Low harmonic distortion
• Lightweight
• UL, CSA, FCC
Application Information
SYLVANIA QUICKTRONIC PS
is ideally suited for:
• Commercial
• Retail
• Hospitality
• Institutional
• New construction
• Direct lighting
• Indirect lighting
• Surface mount
• Cove lighting
56
SYLVANIA QUICKTRONIC PS operates PENTRON T5 lamps with full lumen output and optimal system performance.
SYSTEM PS ballasts contain QUICKSENSE ballast technology, a patented circuitry designed to shut down the system reliably and safely when lamps reach end-of-life.
Setting the standard for quality, SYSTEM PS is also covered by our QUICK 60+ warranty, the first and most compre­hensive system warranty in the industry.
SYSTEM PS is available as a two lamp model which can be wired for one lamp operation to cover a wide range of applications.
System Information
System PS operates from 120V through 277V, 50 or 60Hz, eliminating “wrong voltage” wiring errors and reducing the number of models in inventory by half.
PROStart ballasts provide optimum starting conditions to provide up to 100,000 switching cycles for use on occupancy sensors and building control systems.
QUICKSENSE ballast technology helps to protect against overheated bases and sockets, as well as cracking of the glass wall, and uses dynamic end-of-lamp-life sensing to avoid false shutdowns caused by some static sensing methods. QUICK­SENSE ballast technology will auto reset when the end-of-life lamps are replaced with new ones.
The two lamp unit can be wired for one lamp operation, allowing for an additional 50% reduction in inventory model numbers.
<10% THD Electronic T5 Fluorescent
Programmed Rapid Start Systems
Normal Ballast Factor
System Type Power System Efficacy (2-lamp) (W) Lumens LPW
F40T12 - Standard Magnetic 96 5795 60 Energy Saver Magnetic 86 5795 67
F34T12 - Energy Saver Magnetic 72 4750 66
QT2x32IS - FO32/800 59 5310 90
QTP2x28T5/UNV PSN - FP28/800 65/63 5800 89/92
SYSTEM PS comes in a 0.87"H x 1.18"W profile, and PENTRON lamps are designed to provide peak performance at 35°C fixture ambient, allowing for smaller and more innovative fixtures.
A complete OSRAM SYLVANIA System Performance Guide showing performance characteristics of lamps and ballasts is available upon request.
Input Initial System
SPECIFICATION DATA
Width
Mounting
Length
Length
Height
BALLAST
1 LAMP
LAMP
White
Black
Red
Blue
2 LAMP
LAMP
LAMP
Blue
Yellow
Red
BALLAST
Black
White
Catalog # Date Type
Project Prepared by
Comments
Normal Ballast Factor
T5 PROStart
®
UNV
Professional Series
Universal Voltage (120-277V)
Input Rated
1
Item Current Lamp1Lumens No. of Factor System1Mean1Power Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens Lumens (Watts) (lm/W) BEF
49181 QTP 2x28T5/UNV PSN 0.55/0.23 FP28T5 2900 2 1.00 5800 5395 65/63 89/92 1.59
(49180)*
1 1.00 2900 2695 32 90 3.13
49171 QTP 1x28T5/UNV PSN 0.28/0.12 FP28T5 2900 1 1.00 2900 2695 32 90 3.13
(49170)*
1: At 35°C lamp ambient temperature. 2: Ballast Efficiency Factor (BEF) shown = (Ballast Factor X 100) divided by Input Power (Note: calculation based on lowest wattage value). *(Item Number) = Item Number/NAED in parentheses are models with leads/wires. Ballast with leads/wires contains 10 pieces each. Ballast without leads contain 20 pieces each
Dimensions: 1 & 2 lamp model enclosure size:
Overall: 14.17"L x 1.18"W x 0.87"H (360mm L x 30mm W x 22mm H) Mounting: 13.74" (349mm)
Wiring:
Push-in connectors Use 18AWG solid copper wire only
Ballast
1
Input1System
Performance Guide
Data based upon SYLVANIA PENTRON lamps shown. QUICKTRONIC®PS ballasts are also compatible with other
2
lamp manufacturers equivalent lamp types that meet ANSI specifications.
Specifications
Starting Method: Programmed
Rapid Start
Ballast Factor: 1.00 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.6 Starting Temp: 0°F (-18°C) min. Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of Rated Input
UL Listed Class P, Type 1, Outdoor, UL Rated Type CC CSA Certified 70°C Max Case Temperature FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62.41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet
3 Data based on PENTRON 28W lamp
types for primary ballast application. See the Sylvania QUICKTRONIC Electronic Ballast Technology and Specification Guide (ECS-ELECTRONIC) for other PENTRON combinations.
4 Operation below 50°F (10°C) may affect
light output or lamp operation – see “Low Temp. Starting” definition. Remote red leads up to 18 feet. Keep blue leads <10 feet.
4
3
4
T5 PSN
®
Product Weight:
1L: 0.68 lbs (0.31kg) each (approx) 2L: 0.88 lbs (0.40kg) each (approx)
Item Number 49181 QTP 2 x 28 T5/UNV PSN
QUICKTRONIC PROFESSIONAL
Number of Lamps (1, 2)
Specifications subject to change without notice.
Starting/Ballast Factor
Line Voltage (120-277V)
Primary Lamp Wattage
System Life / Warranty
QUICKTRONIC products are covered by our QUICK 60+®warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
57