Sylvania T5 PSL EXTRA LOW BF DATASHEET

www.sylvania.com
QUICKTRONIC®PROStart®T5 Universal Voltage
Professional Series
Lamp / Ballast Guide
28W T5 - PENTRON
2-lamp QTP2x21T5/UNV PS51-SC
Primary Lamp Type:
FP21
Also operates:
FP14, FP28
2-lamp model operate PENTRON lamps
• 36W @ 0.49 Ballast Factor FP28T5
• 29W @ 0.51 Ballast Factor FP21T5
• 21W @ 0.57 Ballast Factor FP14T5
®
Key System Features
• Low ballast factor
• QUICKSENSE®ballast technology (end-of-lamp-life sensing)
• PROStart programmed rapid start
• 50°F (10°C) starting temperature
• Universal voltage (120-277V)
• Operates at >40 kHz to reduce potential interference with infrared
T5 PSL (EXTRA LOW BF)
control systems
• High power factor (>98%)
• Low harmonic distortion
• Lightweight
• UL, CSA, FCC
• Small can enclosure
Application Information
SYLVANIA QUICKTRONIC PS
is ideally suited for:
• Cove lighting
• Stairways
• Hallways
• Display cases
• Wall wash
SYLVANIA QUICKTRONIC PS operates PENTRON T5 lamps with optimum energy savings at lower light levels.
SYSTEM PS ballasts contain QUICK­SENSE ballast technology, a patented circuitry designed to shut down the system reliably and safely when lamps reach end-of-life.
Setting the standard for quality, SYSTEM PS is also covered by our QUICK 60+®warranty, the first and most comprehensive system warranty in the industry.
System Information
SYLVANIA QUICKTRONIC PROStart System advantages:
• Operate from 120V through 277V
• Eliminates “wrong voltage” errors
• Reduces ballast inventory by 50%
• Utilizes Programmed Rapid Start operation for:
• Longer life
• Over 100,000 switching cycles for occupancy sensor and building control systems applications
QUICKSENSE ballast technology helps to protect against overheated bases and sockets, as well as cracking of the glass wall, and uses dynamic end-of-lamp-life sensing to avoid false shutdowns caused by some static sensing methods. QUICK­SENSE ballast technology will auto reset when the end-of-life lamps are replaced with new ones.
<10% THD Electronic T5 Fluorescent
Programmed Rapid Start Systems
Extra Low Ballast Factor
Input Initial System System Type Power System Efficacy (2-lamp) (W) Lumens LPW
F40T12 - Standard Magnetic 96 5795 60 Energy Saver Magnetic 86 5795 67
F34T12 - Energy Saver Magnetic 72 4750 66
QTP2x32ISL - FO32/800XP 51 4680 92
QTP2x32ISL - FO28/SS 45 4250 94
QTP2x21T5 UNV PS51-SC - FP28/800 36 2840 79
54
SPECIFICATION DATA
ELECTRONIC
BALLAST
Lamp 2
Lamp 1
Yellow
Red
Blue
Black
White
Catalog # Date Type
Project Prepared by
Comments
Extra Low Ballast Factor
T5 PROStart
®
UNV
Professional Series
<10% THD Electronic T5 Fluorescent Systems Extra Low Ballast Factor
Input Rated
1
Item Current Lamp1Lumens No. of Factor System1Mean1Power Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens Lumens (Watts) (lm/W) BEF
49187 QTP2x21T5/UNV PS51-SC 0.31 FP28T5 2900 2 0.49 2840 2645 36 79 1.36
0.24 FP21T5 2100 2 0.51 2140 1990 29 74 1.76
0.18 FP14T5 1350 2 0.57 1535 1430 21 73 2.71
1: At 35°C lamp ambient temperature. 2: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value).
Ballast
1
Input1System
Installation Notes
• Install in accordance with National & Local Electric Code
• Ground ballast case
2-Lamp QTP
Fixed output only
Dimensions:
Overall: 9.5" L x 1.68" W x 1.18" H Mounting: 8.90"
Product Weight:
1.6 lbs each (approx)
Wiring:
Leads only (no connectors provided)
Height
8.70 mm Slot
Width
Mounting
Length
Length
Performance Guide
Data based upon SYLVANIA PENTRON lamps shown. QUICKTRONIC®PS ballasts are also compatible with
2
other lamp manufacturers equivalent lamp types that meet ANSI standards.
Specifications
Starting Method: Programmed
Rapid Start
Ballast Factor: 0.51 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.6 Starting Temp: 50°F (10°C) min. Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of Rated Input
UL Listed Class P, Type 1, Outdoor CSA Certified 70°C Max Case Temperature FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62.41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (Max. wire length from ballast case to lampholder): up to 8 feet
3 Data based on PENTRON 21W lamp
types for primary ballast application. See the Sylvania QUICKTRONIC Ballast Technology and Specification Guide (ECS-ELECTRONIC) for other PENTRON combinations.
System Life / Warranty
QUICKTRONIC products are covered by our QUICK 60+®warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin.
®
Electronic
®
3
NEW!
T5 PSL (EXTRA LOW BF)
Item Number 49187 QTP 2 x 21 T5/UNV PS51 - SC
QUICKTRONIC PROFESSIONAL
Number of Lamps
Specifications subject to change without notice.
Case Size
Starting/Ballast Factor
Line Voltage
Primary Lamp Wattage
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
55
Loading...