• Operates at >40 kHz to reduce
potential interference with infrared
control systems
• High power factor
• Low harmonic distortion
• Lightweight
• UL, CSA, FCC
Application Information
SYLVANIA QUICKTRONIC PHO HT
is ideally suited for:
• Industrial high-bay
• Commercial
• Retail
• Hospitality
• Institutional
• New construction
• Direct lighting
• Indirect lighting
• Surface mount
• Cove lighting
64
SYLVANIA QUICKTRONIC HIGH
AMBIENT (HT) PHO operates
PENTRON HO, PENTRON HO Circline,
and DULUX®L T5 lamps with full
lumen output and optimal system
performance.
SYSTEM PHO High Ambient
Temperature ballasts are specifically
designed for applications where the
ballast is subjected to higher ambient
temperatures, as in high bay industrial installations. The four lamp UNV
(120-277V) ballast system provides
18,600 mean lumens, which, when
factoring in lumen maintenance and
typical T5HO fixture efficiency, can be
considered as a direct replacement
for standard 400W MH. As such, the
family is ideally suited to replace
250W and 400W metal halide installations.
Unique to the family is the 120-277V
4-lamp “switching” ballast, designed to
switch from 4- to 2-, 3- to 2-, 3- to 1- or
2- to 1-lamps. The switching feature can
be accessed through a second input power
System Information
System PHO HT operates on 120V
through 277V, 50 or 60Hz current, eliminating “wrong voltage” wiring errors and
reducing the number of ballast models in
inventory by half.
PROStart ballasts provide optimum starting
conditions and provide up to 100,000
switching cycles for use on occupancy
sensors and building control systems.
QUICKSENSE ballast technology helps to
protect against overheated bases and
sockets, as well as cracking of the lamp
glass wall, and uses dynamic end-oflamp-life sensing to avoid false
shutdowns caused by some static
sensing methods. QUICKSENSE ballast
technology will auto reset when spent
lamps are replaced with new ones.
<10% THD Electronic T5HO Fluorescent
Programmed Rapid Start Ballasts
Normal Ballast Factor
terminal.This feature allows for a range ofcontrol interfaces, including an occupancysensor, mounted inside a fixture.
SYSTEM PHO HT ballasts contain QUICK-
®
SENSE
ballast technology, a patented
circuitry designed to shut down the
system reliably and safely when lamps
reach end-of-life.
System Type(W)LumensLPW
F40T12 - E.S. Magnetic Ballast (4-lamp)1721159067
F34T12 - E.S. Magnetic Ballast (4-lamp)144950066
The four lamp unit can be wired for four,
three, two or one lamp operation. The
two lamp unit can be wired for one lamp
operation, allowing for an additional 50%
reduction in inventory model numbers.
SYSTEM PHO HT has a 25.4H (mm)
profile. PENTRON T5 lamps are designed
to provide peak performance at 35°C
fixture ambient, allowing for smaller and
more innovative fixtures.
Setting the standard for quality, SYSTEMPHO HT is also covered by our QUICK 60+warranty, the first and most compre-
hensive system warranty in the industry.
SYSTEM PHO HT is available in four and
two lamp models to cover a wide range
of applications.
Dimensions:
Model QTP2x54 T5HO/UNV PSN HT enclosure size:
Overall: 16.73"L x 1.18"W x 1.0"H (425mm L x 30mm W x 25.4mm H)
Mounting: 16.34" (415mm)
Wiring:
Push-in connectors
Use 18AWG solid copper wire only
See page 66 for wiring diagram.
Packaging:
Quantity: 20 (2-lamp)
Weight: 2L: 0.88 lbs each (approx)
30.0 mm
1.18”
Width
Dimensions:
Model QTP4x54 T5HO/UNV PSN HT W enclosure size:
Overall: 16.73"L x 2.32"W x 1.0"H (425mm L x 59mm W x 25.4mm H)
Mounting: 16.34" (415mm)
Wiring:
Push-in connectors
Use 18AWG solid copper wire only
See page 67 for wiring diagram.
Packaging:
Quantity: 2-Lamp: 20 (no leads)
10 (with leads)
4-Lamp: 10 (leaded and non-leaded)
59.0 mm
2.32”
Width
Weight: 2L: 0.88 lbs, 0.40kg each (approx)
4L: 1.68 lbs, 0.76kg each (approx)
Item Number49161 QTP 4 x 54 T5HO / UNV PSN HTW
QUICKTRONIC PROFESSIONAL
Number of Lamps
Specifications subject to change without notice.
Ballast
1
414.0 mm
16.3”
Mounting Length
Input1System
25.4 mm
1.0”
Height
425.0 mm
16.73”
Length
414.0 mm
16.3”
Mounting Length
425.0 mm
16.73”
Length
High Ambient Temperature (Case)
Starting/Ballast Factor
Line Voltage (120-277V)
Primary Lamp Wattage
25.4 mm
1.0”
Height
Performance Guide
Data based upon SYLVANIA
®
PENTRON
QUICKTRONIC
2
also compatible with other lamp
HO lamps shown.
®
PHO HT ballasts are
manufacturers equivalent lamp
types that meet ANSI specifications.
Specifications
Starting Method: Programmed
Rapid Start
Ballast Factor: 1.00
Circuit Type: Series
Lamp Frequency: >40 kHz
Lamp CCF: Less than 1.6
Starting Temp: -20°F (-29°C) min.
Input Frequency: 50/60 Hz
Low THD: <10%
Power Factor: >98%
Voltage Range: ±10% of 120-277V
rated line (108-305V)
UL Listed Class P, Type 1, Outdoor,
UL Type CC Rated
CSA Certified
High Ambient Applications:
90°C Max. Case Temp. (3 yr. warranty)
Standard Ambient Applications:
70°C Max. Case Temp. (5 yr. warranty)
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting (Max. wire length
from ballast case to lampholder):
up to 18 feet
3 Data based on PENTRON HO lamp types
for primary ballast application.
4 Operation below 50°F (10°C) may affect
light output or lamp operation – see “Low
Temp. Starting” definition. Remote red and
brown leads up to 18 feet. Keep blue and
yellow (for 4-lamp model only) leads <10 ft.
4
System Life / Warranty
QUICKTRONIC®products are covered
by our QUICK 60+®warranty, a
comprehensive lamp and ballast
system warranty. For additional
details, refer to our QUICK 60+
warranty bulletin.
OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com
3
4
T5HO PSN HT
65
Page 3
BALLAST
1 LAMP
LAMP
Black
White
Red
Blue
2 LAMP
LAMP
LAMP
Blue
Yellow
Red
BALLAST
Black
White
SPECIFICATION DATA
Catalog #DateType
ProjectPrepared by
Comments
2 LAMP T5HO UNV HT
Fixed Output Ballast
Professional Series
<10% THD Electronic 2 Lamp T5HO High Ambient Fluorescent Systems
High ambient model (90°C case temp.)
49136 QTP 2x54T5HO/UNV PSN HT
Wiring diagram for 2-Lamp model
T5HO PSN HT
Lamp / Ballast Guide
Installation Notes
• Install in accordance with National
& Local Electric Code
• Ground ballast case
• Switching: Simultaneously
disconnect all ungrounded line
conductors
Item Number49136 QTP 2 x 54 T5HO / UNV PSN HT
QUICKTRONIC PROFESSIONAL
Number of Lamps (1, 2)
66
Specifications subject to change without notice.
2-Lamp model can be wired for one lamp operation.
High Ambient Temperature (Case)
Starting/Ballast Factor
Line Voltage (120-277V)
Primary Lamp Wattage
OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com
Page 4
SPECIFICATION DATA
S1
S2
(Red Switching Line)
Output A
Output B
S1
S2
(Red Switching Line)
Output A
Output B
S1
S2
(Red Switching Line)
Output A
Output B
Catalog #DateType
ProjectPrepared by
Comments
4 LAMP T5HO UNV HT
Switchable Ballast
Professional Series
<10% THD Electronic 4 Lamp T5HO High Ambient Fluorescent Systems
4-Lamp Switching Wiring Diagram (4L to 2L)
S1 (Output A)S2 (Output B)Lamp Control
Closed (ON)Closed (ON)All 4 Lamps ON (Output A&B ON)
Closed (ON)Open (OFF)2 Lamps ON (Output A ON)
Open (OFF)Closed (ON)2 Lamps ON (Output B ON)
Open (OFF)Open (OFF)All Lamps OFF
High ambient switchable model (90°C case temp.)
49161 QTP 4x54T5HO/UNV PSN HT W
3-Lamp Switching Wiring Diagram (3L to 2L, 3L to 1L)
S1 (Output A)S2 (Output B)Lamp Control
Closed (ON)Closed (ON)All 3 Lamps ON (Output A&B ON)
Closed (ON)Open (OFF)2 Lamps ON (Output A ON)
Open (OFF)Closed (ON)1 Lamp ON (Output B ON)
Open (OFF)Open (OFF)All Lamps OFF
Switching Schematics
T5HO PSN HT
Installation Notes
• Install in accordance with National
& Local Electric Code
• Ground ballast case
• Switching: Simultaneously
disconnect all ungrounded line
conductors
• The AC line inputs must be
connected to the same phase of
the line voltage
• DO NOT CONNECT two separate
phases of line voltage to the input
of the ballast
2-Lamp Switching Wiring Diagram (2L to 1L)
S1 (Output A)S2 (Output B)Lamp Control
Closed (ON)Closed (ON)2 Lamps ON (Output A&B ON)
Closed (ON)Open (OFF)1 Lamp ON (Output A ON)
Open (OFF)Closed (ON)1 Lamp ON (Output B ON)
Open (OFF)Open (OFF)All Lamps OFF
Item Number49161 QTP 4 x 54 T5HO / UNV PSN HTW
QUICKTRONIC PROFESSIONAL
Number of Lamps
Specifications subject to change without notice.
High Ambient Temperature (Case)
Starting/Ballast Factor
Line Voltage (120-277V)
Primary Lamp Wattage
Input wiring for non-switching operation
(Install jumper between black & red
switching line terminals)
Input wiring for occupancy sensors
(Install occupancy sensor/switch between
black & red line terminals)
OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com
67
Loading...