Sylvania T5HO 347-480V HT DATASHEET

www.sylvania.com
QUICKTRONIC®PROStart®T5HO 347-480V High Ambient Temp.
Professional Series
Lamp / Ballast Guide
54W T5 - PENTRON®HO
1 or 2-lamp QTP2x54T5HO/347-480 PSN HT
Also operates:
FT55DL, FT50DL, FPC55, L58
Two lamp model can be wired for one lamp operation.
Key System Features
• 90°C maximum case temp.
• 347-480V input voltage range
• Low-profile (1.00" High)
• QUICKSENSE®ballast technology (end-of-lamp-life sensing)
• PROStart programmed rapid start
• UL type CC rated
T5HO 347-480V HT
• 0°F (-18°C) Starting
• Operates at >40 kHz to reduce potential interference with infrared control systems
• High power factor
• Low harmonic distortion
• Lightweight
• UL, CSA, FCC
Application Information
SYLVANIA QUICKTRONIC PHO
is ideally suited for:
• Industrial high-bay
• Commercial
• Retail
• Hospitality
• Institutional
• New construction
• Direct lighting
• Indirect lighting
• Surface mount
• Cove lighting
SYLVANIA 347-480V QUICKTRONIC HIGH AMBIENT (HT) PHO operates PENTRON
HO, PENTRON HO Circline, and DULUX®L T5 lamps with full lumen output and optimal system performance.
SYSTEM 347-480V PHO HT allows operation of the ballasts in industrial applications using a 480V AC system. This eliminates the need to rewire existing 480V installations or to drop the voltage by using expensive and bulky trans­formers. The same product can also be used for 347V applications, allowing for a reduction in inventory model numbers.
SYSTEM 347-480V PHO HT is specifically designed for high ambient temperature applications. The ballast can be operated at case temperatures of up to 90°C, making it an ideal choice for high ambient settings such as industrial high-bay lighting.
SYSTEM 347-480V PHO HT ballasts contain QUICKSENSE ballast technology, a patented circuitry designed to shut down the system reliably and safely when lamps reach end-of-life.
System Information
SYSTEM 347-480V PHO HT operates from 347V through 480V, 50 or 60Hz, eliminating “wrong voltage” wiring errors and reducing the number of models in inventory by half.
PROStart ballasts provide optimum starting conditions to provide up to 100,000 switching cycles for use on occupancy sensors and building control systems.
QUICKSENSE ballast technology helps to protect against overheated bases and sockets, as well as cracking of the glass wall, and uses dynamic end-of-lamp-life sensing to avoid false shutdowns caused by some static sensing methods. QUICK­SENSE ballast technology will auto reset when the end-of-life lamps are replaced with new ones.
<10% THD Electronic T5HO Fluorescent
Programmed Rapid Start Systems
Normal Ballast Factor
Setting the standard for
quality, SYSTEM 347-480V PHO HT is also covered by our QUICK 60+ warranty, the first and most compre- hensive system warranty in the industry.
SYSTEM 347-480V PHO HT is available in a two lamp model to cover a wide range of applications. The same ballast can be wired for 1 or 2 lamp operation.
System Type (W) Lumens LPW
F40T12 - E.S. Magnetic Ballast (4-lamp) 172 11590 67 F34T12 - E.S. Magnetic Ballast (4-lamp) 144 9500 66
FO32T8/XP - QT4x32IS (4-lamp) 114 10800 95 FP54T5 - QTP2x54T5HO/347-480 PSN HT (2-lamp) 121 10000 83
The two lamp unit can be wired for one lamp operation, allowing for an additional 50% reduction in inventory model numbers.
SYSTEM 347-480V PHO HT comes in a
25.4H or 30H mm profile, and PENTRON lamps are designed to provide peak performance at 35°C fixture ambient, allowing for smaller and more innovative fixtures.
®
Input Initial System
Power System Efficacy
HT
68
SPECIFICATION DATA
BALLAST
1 LAMP
LAMP
Red
Blue
Line Input
2 LAMP
LAMP
LAMP
Blue
Yel lo w
Red
BALLAST
Line Input
Catalog # Date Type
Project Prepared by
Comments
Normal Ballast Factor
T5HO 347-480V HT
Professional Series
High Ambient (347-480V)
Input Rated
1
Item Current Lamp Lumens No. of Factor System1Mean1Power Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens Lumens (Watts) (lm/W) BEF
49146 QTP 2x54T5HO/347-480 PSN HT 0.35/0.25 FP54T5HO 5000 2 1.00 10000 9300 121/120 83 0.83
(49145)*
1: At 35°C lamp ambient temperature. 2: Ballast Efficiency Factor (BEF) shown = (Ballast Factor X 100) divided by Input Power (Note: calculation based on lowest wattage value). *(Item Number) = Item Number/NAED in parentheses are models with leads/wires. Ballast with leads/wires contains 10 pieces each. Ballast without leads contain 20 pieces each *(49145) QTP 2x54T5HO/347-480 PSN HT: same as 49146, with leads.
1 1.00 5000 4650 61 82 1.64
Ballast
1
Input1System
Installation Notes
• For 480V applications connect two phases (line and line) to the input
• For 347V applications connect line and neutral to the input as shown (DO NOT CONNECT two phases of 347V to the same ballast)
• Switching: Simultaneously disconnect all ungrounded line conductors per NEC codes (i.e. switch both hot legs)
• Ground ballast case: Install in accordance with the National Electric Code
Dimensions: Model QTP2x54 T5HO/347-480 PSN HT enclosure size:
Overall: 16.73"L x 1.18"W x 1.0"H (425mm L x 30mm W x 25.4mm H) Mounting: 16.34" (415mm)
Wiring:
Push-in connectors Use 18AWG solid copper wire only
Product Weight:
0.88 lbs (0.40kg) each (approx)
30.0 mm
1.18 Width
Item Number 49146 QTP 2 x 54 T5HO/347-480 PSN HT
QUICKTRONIC PROFESSIONAL
Number of Lamps (2)
Specifications subject to change without notice.
Line
Input
414.0 mm
16.3 Mounting Length
480V 347V
Line
(Black)
Line
(Black)
425.0 mm
16.73 Length
High Case Temp. Rating
Starting/Ballast Factor
Line Voltage (347-480V)
Primary Lamp Wattage
Line
(Black)
Neutral (White)
25.4 mm
1.0 Height
Performance Guide
Data based upon SYLVANIA PENTRON HO lamps shown. QUICKTRONIC 347-480V PHO HT ballasts are
2
also compatible with other lamp manufacturers equivalent lamp types that meet ANSI specifications.
Specifications
Starting Method: Programmed
Rapid Start
Ballast Factor: 1.00 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.6 Starting Temp: 0°F (-18°C) min Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of Rated Input
UL Listed Class P, Type 1, Outdoor, UL Type CC Rated CSA Certified
High Ambient Applications:
90°C Max. Case Temp. (3 yr. warranty)
Standard Ambient Applications:
70°C Max. Case Temp. (5 yr. warranty) FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62.41 Cat. A Transient Protection Dynamic End-of-Lamp-Life Sensing Remote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet
3 Data based on PENTRON HO lamp types
for primary ballast application.
4 Operation below 50°F (10°C) may affect
light output or lamp operation – see “Low Temp. Starting” definition. Remote red leads up to 18 feet. Keep blue leads <10 feet.
4
System Life / Warranty
QUICKTRONIC products are covered by our QUICK 60+®warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
®
®
3
4
T5HO 347-480V HT
69
Loading...