57
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
Starting Method: PROStart
®
Programmed Rapid-Start
Circuit Type: Series
Lamp Frequency: > 40KHz
Lamp CCF: Less than 1.7
Starting Temp: –5°F/–20°C min.
5
Input Frequency: 50/60 Hz
Low THD: < 10%
Power Factor: > 98%
Voltage Range: 108–305V
UL Listed Class P, Type 1 Outdoor
CSA or C/UL Certified
75°C Max Case Temp. (5 yr. warranty)
80°C Max Case Temp. (3 yr. warranty)
FCC 47CFR Part 18 Non-Consumer
Sound Rated A
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting Capability
6
Performance Guide
Specifications*
Ordering Guide
<10% THD Electronic T4 Compact Fluorescent Systems
Dimensions: Packaging:
Metal “M” case: 4.95" L x 2.93" W x 1.35" H Quantity: 1 piece
Plastic “S” case: 4.95" L x 2.37" W x 1.10" H Weight: 0.40 lbs ea. (Plastic “S” case)
Mounting: Utilize flanges (4.57" L) 0.90 lbs ea. (Metal “M” case)
* See the SYLVANIA QUICKTRONIC Electronic Ballast Technology & Specification Guide (ECS-ELECTRONIC) for additional information.
* See wiring diagrams for proper installation.
5 Operation below 50°F may affect light output or lamp operation – see “Low Temperature Starting definition.
6 Typically 6 ft. with suitable ground plane, but varies by model and application – please contact ECS Application Engineering for information on longer applications.
Input Input Rated
2
Ballast Input System
Item Voltage Current Lamp1Lumens No. of Factor System Power Efficacy
Number Description
3
(VAC) (AMPS) Type (lm) Lamps (BF) Lumens (Watts) (lm/W)
13W DD/E,T/E 900 1 1.00 900 16 56
51810 QTP 1/2x13CF/UNV DS 120-277 0.25/0.11
13W DD/E,T/E 900 2 1.00 1800 29 62
18W DD/E,T/E 1200 1 1.00 1200 20 60
51811 QTP 1/2x18CF/UNV DS 120-277 0.32/0.14
18W DD/E,T/E 1200 2 1.00 2400 38 63
26W DD/E,T/E 1800 1 1.00 1800 28 64
51812 QTP 2x26/1x42/32CF/UNV DS 120-277 0.50/0.22
26W DD/E,T/E 1800 2 1.00 3600 54 67
32W DT/E 2400 1 0.98 2350 35 67
42W DT/E 3200 1 1.00 3200 45 71
26W DT/E 1800 2 1.02 3670 54 68
32W DT/E 2400 2 0.96 4600 69 67
518134QTP 2x26/32/42CF/UNV DM 120-277 0.90/0.40 42W DT/E 3200 2 0.95 6080 94 65
0.53/0.23 57W DT/E 4300 1 1.00 4300 62 69
0.57/0.25 70W DT/E 5200 1 0.92 4780 71 67
1 Also compatible with other manufacturers’ equivalent 4 pin lamp types that meet ANSI standards.
2 Rated lamp lumens and performance data based on DULUX T/E series 4 pin lamps.
3 Data is for all three models within the brackets. The maximum input current is shown for maximum input power.
4 Q1 2006
Item Number 51813 QTP 2 x 26/32/42 CF/UNV DM Case Type (Mounting Style)
QUICKTRONIC PROFESSIONAL Line Voltage
Number of Lamps (1, 2) Primary Lamp Wattage
DUAL MOUNT
CF UNIVERSAL
Normal Ballast Factor