dimming inputs from 0-10V and/
or two-wire AC dimming providing
maximum flexibility
• POWERSENSEcompatibilitywithlow
voltage and power line dimmers
• HighEfciency
• LampDetectionTechnology
• Universalvoltage(120-277V)
• 100-1%DimmingRange
• PROStart® programmed rapid start
• Anti-ashcircuitry–turnsonin
dimmed mode
• Lightweightandlowprole
• Operatesat>42kHz
• QUICKSENSEballasttechnology
(end-of-lamp-life sensing)
• QUICK60+ballastandlampwarranty
• RoHScompliant
• Lead-freesolder,printedcircuit
board and manufacturing process
Application Information
SYLVANIA QUICKTRONIC
POWERSENSE ballast
is ideally suited for:
• Occupancysensors
• Daylightharvesting
• Energymanagement
• Loadshedding
• Commercial
• Retail
• Hospitality
• Institutional
• Schools
• Newconstruction
• Retrot
SYLVANIA QUICKTRONIC POWERSENSE
ballasts operate linear fluorescent T5 lamps
over a wide (100-1%) dimming range and
provide true versatility in controls selection.
QUICKTRONIC POWERSENSE ballasts
feature micro-controller technology to offer
the industry’s most adaptable dimming
ballast. Compatibility with low voltage
controls, power line dimmers and any line
voltage from 120V to 277V, provides the
flexibility to greatly simplify the specification, purchasing and installation process.
Patented lamp detection technology
delivers unmatched performance.
Variations in brightness from lamp-tolamp are virtually eliminated, providing
uniform lighting throughout the dimming
range. At light levels of >75% unnecessary lamp-coil power is turned off,
delivering energy efficiences comparable
to non-dimming Instant start electronic
ballast. This technology also eases installation and troubleshooting by recognizing
failed lamps, faulty wiring or loose
System Information
QUICKTRONIC POWERSENSE ballasts
operate from standard low voltage
(0-10VDC) fluorescent controllers or
compatible 2-wire power line fluorescent
dimmers, making them ideal for
individual office lighting or automated
building applications, both in new
construction and retrofit projects.
For the individual office or conference
room, installation can be streamlined
by using a 2-wire power line dimmer;
eliminating the need for additional control
wires.
For more advanced systems, such as
daylight harvesting or building automation
applications, standard low voltage
devices (0-10VDC, Class 1 or 2) are used
to control the lighting system. In this
daylight harvesting example, each lighting
fixture (or fixture row) is controlled by
it’s own photosensor; regulating the
connections, and shutting down. When
the problem is corrected, the system
restarts automatically.
All SYLVANIA Professional Series (QTP)
electronic ballasts feature high power
quality (<10% THD), lightweight, low
profile designs.
light output to compensate for changes
in natural daylight. Depending upon the
specific application, energy savings of
up to 60% compared to fixed output
electronic systems can be realized.
Daylight Harvesting Scenario
Fixture
Light Sensor 1Light Sensor 2Light Sensor 3
1
Window / Natural Light Source
Electronic T5
Fluorescent Controllable
Lighting Systems
These ballasts are RoHS compliant and
feature lead-free solder, printed circuit
boards and manufacturing process.
Setting the standard for quality,
QUICKTRONIC POWERSENSE ballasts are
covered by the QUICK 60+® warranty,
the first and most comprehensive lamp &
ballast system warranty in the industry.
All QUICKTRONIC POWERSENSE ballasts
include a line voltage protection circuit,
which protects the ballast in the event
that line voltage is inadvertently applied
to the low voltage control inputs.
Fixture
2
Fixture
3
Desired Illuminance E
Constant setpoint value
r
P O W E R S E N S E
T 5 D I M
ECS238 – 1/2011
SPECIFICATION DATA
Catalog # Date Type
Project Prepared by
Comments
T5 POWERSENSE
High Efficiency
QUICKTRONIC® POWERSENSE® Controls Information
Fluorescent Building
Controls Powerline 0-10 VDC Photo Occupancy Management
Manufacturer Controllers Controllers Cells Sensors Systems
SYLVANIA ELOGIC™ Controls
1-800-LIGHTBULB
www.sylvania.com x x x x
Hunt Dimming
970-484-9048
www.huntdimming.com x x x x x
Lehigh Electronic Products
C O N T R O L S
610-395-3386
P O W E R S E N S E
www.lehighdim.com x x x x x
Leviton Lighting Controls
800-824-3005
www.leviton.com x x x x
Lightolier Controls
800-526-2731
www.lolcontrols.com x x x x x
Lithonia Controls
800-533-2719
www.lithonia.com x x x x x
Lumisys
800-241-9173
www.lumisys1.com x x x
PCI
800-767-3674
www.pcilightingcontrols.com x x
Sensorswitch
1-800-PASSIVE
www.sensorswitch.com x x
Siemens Energy & Automation
800-427-2256
www.sea.siemens.com x
Starfield Controls
303-427-1661
www.starfieldcontrols.com x x x x
The Watt Stopper, Inc
800-879-8585
www.wattstopper.com x x
Please contact controls manufacturers to order/specify controls. For the latest controls list go to www.sylvania.com
Also for more information, check out the LCA (Lighting Controls Association) site: www.aboutlightingcontrols.org
Controls Guide
Contact the companies listed for their
2-wire Fluorescent/Powerline controls
and/or 0-10V controls information.
Install and wire these ballast and controls in accordance with the National Electrical Code (NEC), all applicable Federal, State
and local electrical codes, as well as the specific instructions provided with the compatible control that you purchased.
Installation should be performed by qualified personnel only.
These instructions are guidelines only. Installation may vary for different controls/fixtures/applications. Be sure to follow the
control instructions and all applicable codes and standards when installing dimming systems.
Please contact controls manufacturer listed in the OSRAM SYLVANIA Inc. controls cross reference for compatible
controls and instruction wiring
NOTES: 1. Dimming ballasts source < 0.5mA (0-10VDC control input).
2. Powerline controls must be rated for the type (e.g. Fluorescent Phase-control) and size
(e.g. 600W, 1000W, 1500W & 2000W etc.) of the connected load. Do NOT use incandescent powerline controls;
incandescent dimmers are not rated for fluorescent loads and are NOT compatible with POWERSENSE ballasts.
Control Specifications/model numbers may change.
Please consult manufacturers listed for their latest control models and to order their controls.
Specifications subject to change without notice.
OSRAM SYLVANIA
National Customer
Service and Sales Center
1-800-LIGHTBULB
(1-800-544-4828)
www.sylvania.com
SPECIFICATION DATA
To
Fluorescent
Lamps
Violet (+)
DIMMING
BALLAST
Black
White
Photo Sensor 0-10V Wiring Example
0-10VDCControlwithPOWERSENSEBallasts
0-10V
Control
Gray (-)
Neutral (White)
120 or 277V
Black (Hot)
LINE
Gray
Violet
Class 1 or Class 2 circuit
To
Fluorescent
Lamps
Violet (+)
DIMMING
BALLAST
Black
White
Gray (-)
To
Additional
Ballasts
Photo
Sensor
0-10V
Standard
Line Voltage
Switch
Black
Photo Sensor 0-10V Wiring Example
0-10V DC Control with POWERSENSE Ballasts
Catalog # Date Type
Project Prepared by
Comments
QUICKTRONIC® POWERSENSE® T5 Dimming UNV - Dimming Control Wiring Examples
Industry’s 1st Ballast that allows POWERLINE Fluorescent Control AND 0-10Vdc Control Input simultaneously
T5 POWERSENSE
High Efficiency
2-wire Powerline AND 0-10Vdc Control with POWERSENSE Ballasts
2-wire
Fluorescent
Fluorescent AC Dimming
No Control Wires
• Occupant Wallbox Dimming
• Lighting Panel Dimming
• Excellent for Retrofit
0-10Vdc Low Voltage
Industry Standard Interface
• Daylight Harvesting
• Building Management
• Demand Response Override
120 or 277V
Black (Hot)
LINE
Neutral (White)
Powerline Dimmer
Black
0-10V
Control
Violet
Black
White
Violet (+)
Gray (-)
Gray
DIMMING
BALLAST
0-10V
Class 1 or Class 2 circuit
To
Fluorescent
Lamps
Wallbox Style 2-wire Powerline Control Wiring Example
Specification-grade controls are available for 120V or 277V
Powerline Control Specs:
operation of controllable analog electronic fluorescent ballasts.
Controls must be suitably rated for both the type (e.g. Fluorescent
Phase-control) and size (e.g. 600W) of the connected load.
ELOGIC™ MANUAL CONTROL SLIDE FLUORESCENT PHASE CUT DIMMER
Maximum Input Current (A)
Item OSRAM SYLVANIA (# of gangs) Input Integral
Number Description Single Double Triple Voltage (V) Color Switch
45045 ELMC-SL-FLPCWALL/120-WH
45046 ELMC-SL-FLPCWALL/277-WH
5.0A 4.5A 4.0A
2.2A 2.0A 1.7A
120
277
Black (Hot)
LINE
Neutral (White)
White
White
2-wire Powerline Control with POWERSENSE Ballasts
2-wire
Fluorescent
Powerline Dimmer
Single Pole
Wallbox Style 0-10V Control with Power Switch Wiring Example
Black
DIMMING
White
Violet (+)
BALLAST
Gray (-)
Black
Black
White
Violet (+)
Gray (-)
For 2-wire Powerline wiring, individually insulate (cap-off)
0-10V
DIMMING
BALLAST
CAUTION:
all unused Violet & Gray leads as shown.
To
Fluorescent
Lamps
To
Fluorescent
Lamps
EXCLUSIVELY
EXCLUSIVELY
from
from
OSRAM
OSRAM
SYLVANIA!
SYLVANIA!
To
Additional
Ballasts
Black
White
Violet (+)
Gray (-)
DIMMING
BALLAST
To
Fluorescent
Lamps
Examples: Leviton IPX series operate as
single pole or 3-way models. Available in
120V and 277V models. Leviton 6668-1W
(white) 120V single pole fluorescent dimmer.
To
Additional
Ballasts
WI R I NG & C ONTR O L S
PO W E RSEN S E
Examples: Lithonia model ISD BC
or Leviton IP 710 Series (These
0-10V dc, 120/277V models can be
wired for single pole application
(shown); these models can also be
wired for 3-way applications.)
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
Specifications subject to change without notice.
0-10V DC Control with POWERSENSE Ballasts
120 or 277V
Black (Hot)
LINE
Neutral (White)
0-10Vdc
Wallbox
Control with
Line Voltage
Switch
Black
Line
Voltage
Switch
0-10V
Control
Black
White
DIMMING
Violet (+)
BALLAST
Gray (-)
Class 1 or Class 2 circuit
Black
Violet
Gray
Photo Sensor 0-10V Wiring Example
Ballast Output Max.
Item OSRAM SYLVANIA Control Voltage Input Lamp
Number Description Type Method (VDC) Current (mA) Type
45030 ELSC-DLH-TVLAMP/BUS
Daylight Harvesting
To
Fluorescent
Lamps
On/Off
Switch (120/277V)
Slide Dimmer
0-10V
Black
White
DIMMING
Violet (+)
BALLAST
Gray (-)
ELOGIC DAYLIGHT SENSOR ORDERING INFORMATION
Sensor & Control for
To
Fluorescent
Lamps
Analog 0-10V 6 T8 or T5 or T5HO
To
Additional
Ballasts
SPECIFICATION DATA
POWERLINE CONTROL
LINE
BLACK
NEUTRAL
WHITE
INSULATEUNUSED LEADS
VIOLET
(+)
GREY(-)
Black
White
Violet (+)Grey (-)
RedRed
BlueBlue
LAMP 1
ELECTRONIC
BALLAST
QTP2x28T5/UNV DIM TCL
Catalog # Date Type
Project Prepared by
Comments
T5 POWERSENSE
High Efficiency
®
High Efficiency Electronic T5 Fluorescent Controllable Lighting Systems
Input Input Rated
Item Voltage Current Lamp Lumens No. of Factor System2 Power Efficacy
Number Description (VAC) (AMPS) Type (lm) Lamps (BF) Lumens (Watts) (lm/W) BEF
1: Rated lamp lumens and performance data based on PENTRON lamps.
2: At 35°C lamp ambient temperature.
3: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (note: calculation based on lowest wattage value)
Dimensions:
2 lamp enclosure
Overall: 16.7" L x 1.68" W x 1.0" H (425 x 43 x 25 mm)
Mounting:16.2" (411 mm)
Weight: 2.1 lbs each (950 g)
Wiring:
Leads Only
Height
25.4mm
(1.0")
1,2
Ballast2 Input2 System
Width
43mm
(1.68")
Mounting
411.3mm
(16.2")
Length
425mm
(16.7")
Performance Guide
Data shown based upon SYLVANIA
PENTRON® lamp(s). QUICKTRONIC®
POWERSENSE ballasts are also compatible
3
with other lamp manufacturers equivalent
lamp types that meet ANSI specifications.
Specifications
Data based on FP28
Starting Method: Programmed Rapid Start
Circuit Type: Series
Lamp Frequency: >40kHz
Lamp CCF: Less than 1.7
Starting Temp: 50°F/10°C minimum
Input Voltage: 120-277V, ±10%
Input Frequency: 50/60 Hz
THD: <10% @ Full Output
Power Factor: >98% @ Full Output
UL Listed Class P, Type 1 Outdoor
CSA or C/UL Certified
70°C Max Case Temperature
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
RoHS Compliant
ANSI C62.41 Cat. A Transient Protection
No Remote or Tandem Wiring
4 Complies with European Union Restriction of
Hazardous Substances Directive.
4
Installation Notes
Output Wiring: Lamp wiring for dimming ballasts can differ significantly from non-dimming
ballasts and from other manufacturers dimming ballasts. Take care to connect lamp lead
wires as shown on the applicable ballast diagram.
Lamp Seasoning: For optimal performance, fluorescent lamps may require seasoning for up to 12 hours prior to low temperature
starting & low level dimming. Refer to NEMA LSD 23-2002 Lighting Systems Division: Recommended Practice — Lamp Seasoning for
Fluorescent Dimming Systems
2 lamp
Input & Control Wiring Options:
LOW-VOLTAGE CONTROL
LINE
NEUTRAL
Class 1 or
Class 2
Item Number 50726 QTP 2 x 28T5 / UNV DIM-TCL
QUICKTRONIC PROFESSIONAL
Number of Lamps (2)
SYLVANIA, PENTRON, QUICKSENSE, the system solution, QUICK60+, PROStart, POWERSENSE and See the World in a New Light are registered trademarks of OSRAM SYLVANIA Inc.
ELOGIC is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH.
Black
White
ELECTRONIC
Violet (+)
Grey (-)
0-10V
< 0.5mA
DC
BLACK
WHITE
VIOLET (+)
GREY (-)
BALLAST
LAMP 1
LAMP 1
LAMP 2
Red
Red
Blue
Blue
Yel/Blk
Yellow
Yellow
POWERLINE CONTROL
LINE
NEUTRAL
INSULATE
UNUSED LEADS
System Type - DIMMING/Case Size
Line Voltage (120-277V)
Primary Lamp Wattage
BLACK
WHITE
VIOLET
GREY (-)
(+)
Control Information
QUICKTRONIC POWERSENSE ballasts
are compatible with a wide range of
low voltage (0-10VDC) and power line
fluorescent controllers available from
various manufacturers.
Low Voltage Control Specs: Ballast will
source up to 0.5mA for 0-10VDC control
purposes. May be wired as a Class 1 or
Class 2 circuit-consult Local and National
Electrical Codes.
Power Line Control Specs: Specificationgrade fluorescent controls are available
for 120V or 277V operation of controllable
analog electronic fluorescent ballasts.
Controls must be suitably rated for both the
type (e.g. Fluorescent Phase-control) and
size (e.g. 600W) of the connected load.
System Life / Warranty
QUICKTRONIC products are covered by the
QUICK 60+® warranty, a comprehensive
lamp and ballast system warranty. For
additional details, refer to the QUICK 60+
warranty bulletin.
OSRAM SYLVANIA
National Customer
Service and Sales Center