28W T5 - PENTRON
2-lamp QTP2x28T5/UNV DIM
Primary Lamp Type
FP28
Also operates:
®
Key System Features
• Industry’srstballastthatcombines
dimming inputs from 0-10V and/ or two-wire AC dimming providing maximum flexibility
• POWERSENSEcompatibilitywithlow
voltage and power line dimmers
• HighEfciency
• LampDetectionTechnology
• Universalvoltage(120-277V)
• 100-1%DimmingRange
• PROStart® programmed rapid start
• Anti-ashcircuitry–turnsonin
dimmed mode
• Lightweightandlowprole
• Operatesat>42kHz
• QUICKSENSEballasttechnology
(end-of-lamp-life sensing)
• QUICK60+ballastandlampwarranty
• RoHScompliant
• Lead-freesolder,printedcircuit
board and manufacturing process
Application Information
SYLVANIA QUICKTRONIC POWERSENSE ballast
is ideally suited for:
• Occupancysensors
• Daylightharvesting
• Energymanagement
• Loadshedding
• Commercial
• Retail
• Hospitality
• Institutional
• Schools
• Newconstruction
• Retrot
SYLVANIA QUICKTRONIC POWERSENSE
ballasts operate linear fluorescent T5 lamps over a wide (100-1%) dimming range and provide true versatility in controls selection.
QUICKTRONIC POWERSENSE ballasts feature micro-controller technology to offer the industry’s most adaptable dimming ballast. Compatibility with low voltage controls, power line dimmers and any line voltage from 120V to 277V, provides the flexibility to greatly simplify the specifi­cation, purchasing and installation process.
Patented lamp detection technology delivers unmatched performance. Variations in brightness from lamp-to­lamp are virtually eliminated, providing uniform lighting throughout the dimming range. At light levels of >75% unnec­essary lamp-coil power is turned off, delivering energy efficiences comparable to non-dimming Instant start electronic ballast. This technology also eases instal­lation and troubleshooting by recognizing failed lamps, faulty wiring or loose
System Information
QUICKTRONIC POWERSENSE ballasts operate from standard low voltage (0-10VDC) fluorescent controllers or compatible 2-wire power line fluorescent dimmers, making them ideal for individual office lighting or automated building applications, both in new construction and retrofit projects.
For the individual office or conference room, installation can be streamlined by using a 2-wire power line dimmer; eliminating the need for additional control wires.
For more advanced systems, such as daylight harvesting or building automation applications, standard low voltage devices (0-10VDC, Class 1 or 2) are used to control the lighting system. In this daylight harvesting example, each lighting fixture (or fixture row) is controlled by it’s own photosensor; regulating the
connections, and shutting down. When the problem is corrected, the system restarts automatically.
All SYLVANIA Professional Series (QTP) electronic ballasts feature high power quality (<10% THD), lightweight, low profile designs.
light output to compensate for changes in natural daylight. Depending upon the specific application, energy savings of up to 60% compared to fixed output electronic systems can be realized.
Daylight Harvesting Scenario
Fixture
Light Sensor 1 Light Sensor 2 Light Sensor 3
1
Window / Natural Light Source
Electronic T5
Fluorescent Controllable
Lighting Systems
These ballasts are RoHS compliant and feature lead-free solder, printed circuit boards and manufacturing process.
Setting the standard for quality, QUICKTRONIC POWERSENSE ballasts are covered by the QUICK 60+® warranty, the first and most comprehensive lamp & ballast system warranty in the industry.
All QUICKTRONIC POWERSENSE ballasts include a line voltage protection circuit, which protects the ballast in the event that line voltage is inadvertently applied to the low voltage control inputs.
Fixture
2
Fixture
3
Desired Illuminance E
Constant setpoint value
r
P O W E R S E N S E
T 5 D I M
ECS238 – 1/2011
SPECIFICATION DATA
Catalog # Date Type
Project Prepared by
Comments
T5 POWERSENSE
High Efficiency
QUICKTRONIC® POWERSENSE® Controls Information
Fluorescent Building Controls Powerline 0-10 VDC Photo Occupancy Management Manufacturer Controllers Controllers Cells Sensors Systems
SYLVANIA ELOGIC™ Controls 1-800-LIGHTBULB www.sylvania.com x x x x
Hunt Dimming 970-484-9048 www.huntdimming.com x x x x x
Lehigh Electronic Products
C O N T R O L S
610-395-3386
P O W E R S E N S E
www.lehighdim.com x x x x x
Leviton Lighting Controls 800-824-3005 www.leviton.com x x x x
Lightolier Controls 800-526-2731 www.lolcontrols.com x x x x x
Lithonia Controls 800-533-2719 www.lithonia.com x x x x x
Lumisys 800-241-9173 www.lumisys1.com x x x
PCI 800-767-3674 www.pcilightingcontrols.com x x
Sensorswitch 1-800-PASSIVE www.sensorswitch.com x x
Siemens Energy & Automation 800-427-2256 www.sea.siemens.com x
Starfield Controls 303-427-1661 www.starfieldcontrols.com x x x x
The Watt Stopper, Inc 800-879-8585 www.wattstopper.com x x
Please contact controls manufacturers to order/specify controls. For the latest controls list go to www.sylvania.com Also for more information, check out the LCA (Lighting Controls Association) site: www.aboutlightingcontrols.org
Controls Guide
Contact the companies listed for their 2-wire Fluorescent/Powerline controls and/or 0-10V controls information.
T5 POWERSENSE Dimming Ballast 50726 QTP 2x28T5/UNV DIM-TCL
WARNING:
Install and wire these ballast and controls in accordance with the National Electrical Code (NEC), all applicable Federal, State and local electrical codes, as well as the specific instructions provided with the compatible control that you purchased. Installation should be performed by qualified personnel only.
These instructions are guidelines only. Installation may vary for different controls/fixtures/applications. Be sure to follow the control instructions and all applicable codes and standards when installing dimming systems.
Please contact controls manufacturer listed in the OSRAM SYLVANIA Inc. controls cross reference for compatible controls and instruction wiring
NOTES: 1. Dimming ballasts source < 0.5mA (0-10VDC control input).
2. Powerline controls must be rated for the type (e.g. Fluorescent Phase-control) and size (e.g. 600W, 1000W, 1500W & 2000W etc.) of the connected load. Do NOT use incandescent powerline controls; incandescent dimmers are not rated for fluorescent loads and are NOT compatible with POWERSENSE ballasts.
Control Specifications/model numbers may change.
Please consult manufacturers listed for their latest control models and to order their controls.
Specifications subject to change without notice.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
SPECIFICATION DATA
To Fluorescent Lamps
Violet (+)
DIMMING BALLAST
Black White
Photo Sensor 0-10V Wiring Example
0-10V DC Control with POWERSENSE Ballasts
0-10V
Control
Gray (-)
Neutral (White)
120 or 277V Black (Hot)
LINE
Gray
Violet
Class 1 or Class 2 circuit
To Fluorescent Lamps
Violet (+)
DIMMING
BALLAST
Black White
Gray (-)
To Additional Ballasts
Photo
Sensor
0-10V
Standard
Line Voltage
Switch
Black
Photo Sensor 0-10V Wiring Example
0-10V DC Control with POWERSENSE Ballasts
Catalog # Date Type
Project Prepared by
Comments
QUICKTRONIC® POWERSENSE® T5 Dimming UNV - Dimming Control Wiring Examples
Industry’s 1st Ballast that allows POWERLINE Fluorescent Control AND 0-10Vdc Control Input simultaneously
T5 POWERSENSE
High Efficiency
2-wire Powerline AND 0-10Vdc Control with POWERSENSE Ballasts
2-wire Fluorescent
Fluorescent AC Dimming No Control Wires
• Occupant Wallbox Dimming
• Lighting Panel Dimming
• Excellent for Retrofit
0-10Vdc Low Voltage Industry Standard Interface
• Daylight Harvesting
• Building Management
• Demand Response Override
120 or 277V Black (Hot)
LINE
Neutral (White)
Powerline Dimmer
Black
0-10V
Control
Violet
Black White
Violet (+)
Gray (-)
Gray
DIMMING BALLAST
0-10V
Class 1 or Class 2 circuit
To Fluorescent Lamps
Wallbox Style 2-wire Powerline Control Wiring Example
Specification-grade controls are available for 120V or 277V
Powerline Control Specs:
operation of controllable analog electronic fluorescent ballasts.
Controls must be suitably rated for both the type (e.g. Fluorescent
Phase-control) and size (e.g. 600W) of the connected load.
ELOGIC™ MANUAL CONTROL SLIDE FLUORESCENT PHASE CUT DIMMER
Maximum Input Current (A) Item OSRAM SYLVANIA (# of gangs) Input Integral Number Description Single Double Triple Voltage (V) Color Switch
45045 ELMC-SL-FLPCWALL/120-WH
45046 ELMC-SL-FLPCWALL/277-WH
5.0A 4.5A 4.0A
2.2A 2.0A 1.7A
120
277
Black (Hot)
LINE
Neutral (White)
White
White
2-wire Powerline Control with POWERSENSE Ballasts
2-wire Fluorescent Powerline Dimmer
Single Pole
Wallbox Style 0-10V Control with Power Switch Wiring Example
Black
DIMMING
White
Violet (+)
BALLAST
Gray (-)
Black
Black White
Violet (+)
Gray (-)
For 2-wire Powerline wiring, individually insulate (cap-off)
0-10V
DIMMING BALLAST
CAUTION:
all unused Violet & Gray leads as shown.
To Fluorescent Lamps
To Fluorescent Lamps
EXCLUSIVELY
EXCLUSIVELY
from
from
OSRAM
OSRAM
SYLVANIA!
SYLVANIA!
To Additional Ballasts
Black White
Violet (+)
Gray (-)
DIMMING BALLAST
To Fluorescent Lamps
Examples: Leviton IPX series operate as single pole or 3-way models. Available in 120V and 277V models. Leviton 6668-1W (white) 120V single pole fluorescent dimmer.
To Additional Ballasts
WI R I NG & C ONTR O L S
PO W E RSEN S E
Examples: Lithonia model ISD BC or Leviton IP 710 Series (These 0-10V dc, 120/277V models can be wired for single pole application (shown); these models can also be wired for 3-way applications.)
OSRAM SYLVANIA National Customer Service and Sales Center 1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
Specifications subject to change without notice.
0-10V DC Control with POWERSENSE Ballasts
120 or 277V Black (Hot)
LINE
Neutral (White)
0-10Vdc
Wallbox Control with Line Voltage
Switch
Black
Line
Voltage
Switch
0-10V
Control
Black White
DIMMING
Violet (+)
BALLAST
Gray (-)
Class 1 or Class 2 circuit
Black
Violet
Gray
Photo Sensor 0-10V Wiring Example
Ballast Output Max. Item OSRAM SYLVANIA Control Voltage Input Lamp Number Description Type Method (VDC) Current (mA) Type
45030 ELSC-DLH-TVLAMP/BUS Daylight Harvesting
To Fluorescent Lamps
On/Off
Switch (120/277V)
Slide Dimmer
0-10V
Black White
DIMMING
Violet (+)
BALLAST
Gray (-)
ELOGIC DAYLIGHT SENSOR ORDERING INFORMATION
Sensor & Control for
To Fluorescent Lamps
Analog 0-10V 6 T8 or T5 or T5HO
To Additional Ballasts
SPECIFICATION DATA
POWERLINE CONTROL
LINE
BLACK
NEUTRAL
WHITE
INSULATE UNUSED LEADS
VIOLET
(+)
GREY (-)
Black
White
Violet (+) Grey (-)
Red Red
Blue Blue
LAMP 1
ELECTRONIC
BALLAST
QTP2x28T5/UNV DIM TCL
Catalog # Date Type
Project Prepared by
Comments
T5 POWERSENSE
High Efficiency
®
High Efficiency Electronic T5 Fluorescent Controllable Lighting Systems
Input Input Rated Item Voltage Current Lamp Lumens No. of Factor System2 Power Efficacy Number Description (VAC) (AMPS) Type (lm) Lamps (BF) Lumens (Watts) (lm/W) BEF
50726 QTP 2x28T5/UNV DIM-TCL 120-277 0.53/0.23 FP28 2900 2 1.00 5800 64/62 91/93 1.61
0.01 58 10
0.67/0.29 FP35 3650 2 1.00 7300 81/79 90/92 1.27
0.01 73 10
0.40/0.18 FP21 2100 2 1.00 4200 49 86 2.04
0.01 42 9
T 5 D I M
0.29/0.13 FP14 1350 2 1.00 2700 34 79 2.94
0.01 27 8
P O W E R S E N S E
1: Rated lamp lumens and performance data based on PENTRON lamps. 2: At 35°C lamp ambient temperature. 3: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (note: calculation based on lowest wattage value)
Dimensions: 2 lamp enclosure
Overall: 16.7" L x 1.68" W x 1.0" H (425 x 43 x 25 mm) Mounting:16.2" (411 mm) Weight: 2.1 lbs each (950 g)
Wiring:
Leads Only
Height
25.4mm (1.0")
1,2
Ballast2 Input2 System
Width 43mm (1.68")
Mounting
411.3mm (16.2")
Length 425mm (16.7")
Performance Guide
Data shown based upon SYLVANIA PENTRON® lamp(s). QUICKTRONIC® POWERSENSE ballasts are also compatible
3
with other lamp manufacturers equivalent lamp types that meet ANSI specifications.
Specifications
Data based on FP28
Starting Method: Programmed Rapid Start Circuit Type: Series Lamp Frequency: >40kHz Lamp CCF: Less than 1.7 Starting Temp: 50°F/10°C minimum Input Voltage: 120-277V, ±10% Input Frequency: 50/60 Hz THD: <10% @ Full Output Power Factor: >98% @ Full Output
UL Listed Class P, Type 1 Outdoor CSA or C/UL Certified 70°C Max Case Temperature FCC 47CFR Part 18 Non-Consumer Class A Sound Rating RoHS Compliant ANSI C62.41 Cat. A Transient Protection No Remote or Tandem Wiring
4 Complies with European Union Restriction of
Hazardous Substances Directive.
4
Installation Notes
Output Wiring: Lamp wiring for dimming ballasts can differ significantly from non-dimming
ballasts and from other manufacturers dimming ballasts. Take care to connect lamp lead wires as shown on the applicable ballast diagram. Lamp Seasoning: For optimal performance, fluorescent lamps may require seasoning for up to 12 hours prior to low temperature starting & low level dimming. Refer to NEMA LSD 23-2002 Lighting Systems Division: Recommended Practice — Lamp Seasoning for Fluorescent Dimming Systems
2 lamp
Input & Control Wiring Options:
LOW-VOLTAGE CONTROL
LINE
NEUTRAL
Class 1 or Class 2
Item Number 50726 QTP 2 x 28T5 / UNV DIM-TCL
QUICKTRONIC PROFESSIONAL
Number of Lamps (2)
SYLVANIA, PENTRON, QUICKSENSE, the system solution, QUICK60+, PROStart, POWERSENSE and See the World in a New Light are registered trademarks of OSRAM SYLVANIA Inc. ELOGIC is a trademark of OSRAM SYLVANIA Inc. QUICKTRONIC is a registered trademark of OSRAM GmbH.
Black White
ELECTRONIC
Violet (+) Grey (-)
0-10V < 0.5mA
DC
BLACK
WHITE
VIOLET (+)
GREY (-)
BALLAST
LAMP 1
LAMP 1
LAMP 2
Red Red Blue Blue
Yel/Blk Yellow Yellow
POWERLINE CONTROL
LINE
NEUTRAL
INSULATE UNUSED LEADS
System Type - DIMMING/Case Size
Line Voltage (120-277V)
Primary Lamp Wattage
BLACK
WHITE
VIOLET
GREY (-)
(+)
Control Information
QUICKTRONIC POWERSENSE ballasts are compatible with a wide range of low voltage (0-10VDC) and power line fluorescent controllers available from various manufacturers.
Low Voltage Control Specs: Ballast will source up to 0.5mA for 0-10VDC control purposes. May be wired as a Class 1 or Class 2 circuit-consult Local and National Electrical Codes.
Power Line Control Specs: Specification­grade fluorescent controls are available for 120V or 277V operation of controllable analog electronic fluorescent ballasts. Controls must be suitably rated for both the type (e.g. Fluorescent Phase-control) and size (e.g. 600W) of the connected load.
System Life / Warranty
QUICKTRONIC products are covered by the QUICK 60+® warranty, a comprehensive lamp and ballast system warranty. For additional details, refer to the QUICK 60+ warranty bulletin.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com