Sylvania QTR T8 RES DATASHEET

www.sylvania.com
QUICKTRONIC®Residential T8 Instant Start
Residential Series
Lamp / Ballast Guide
32W T8 - OCTRON
2 or 1 lamp QTR2x32T8/120 ISN-SC 4 or 3 lamp QTR4x32T8/120 ISN-SC
Also operates:
FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS, FBO30/SS (30W), FBO29/SS (29W), FO28/SS (28W) & FO25/SS (25W)
F40T8 operation:
1 lamp on 2L ballast 3 lamp on 4L ballast
Key System Features
• Energy Star®compliant
• RESIDENTIAL USE ONLY
• Normal power factor (>0.50)
• High THD (<200%)
• FCC Consumer Compliant
• Small can housing (SC)
• Normal ballast factor
• 30-40% Energy savings
• 0°F (-18°C) min. starting temp. for OCTRON lamps
• 60°F (16°C) min. starting temper­ature with energy saving T8 lamps
• High luminous efficacy
• Virtually eliminates lamp flicker
QTR T8 RES
• Quiet operation
• Lightweight
Application Information
SYLVANIA QUICKTRONIC Residential Series are ideally suited
for Residential Fixtures:
• Energy Star®fixtures
• New residential construction
• Direct lighting
• Indirect lighting
• Surface mount
• Cove lighting
®
SYLVANIA QUICKTRONIC RESIDENTIAL
balllasts bring all the energy saving features of our standard commercial grade ballast to an economical design acceptable for residential fixtures. These ballasts comply with FCC-Consumer requirements thereby making them a perfect complement for your ENERGY STAR®rated fixture. These QTR ballasts are for residential use only.
SYLVANIA QUICKTRONIC RESIDENTIAL T8
electronic ballasts operates OCTRON T8 lamps with maximum efficacy and high lumen output, and provides 30-40% energy savings when compared to F40T12 magnetic systems.
Small can enclosure allows for low profile fixture design and application.
Parallel circuitry is utilized to keep the remaining lamps lit if one or more should go out.
System Information
SYLVANIA QUICKTRONIC RESIDENTIAL T8
uses instant start operation to provide the highest system efficacy and to assure low temperature starting capability. Instant start also provides for maximum remote wiring distances.
For Residential Use Only
Normal Power Factor
QUICKTRONIC RESIDENTIAL T8 is available in two and four lamp models in 120V to cover a wide range of applications.
System Type Power Initial System 2-lamp ISN-SC (W) Lumens LPW
F40T12 Std. Magnetic Ballast 96 5795 60
F34T12 Std. Magnetic Ballast 82 4750 58
F32T8/700 Magnetic 71 5320 75
FO32/800XP QTR2x32T8/120 ISN-SC 55 5220 95
System Type Power Initial System 4-lamp ISN (W) Lumens LPW
F40T12 Std. Magnetic Ballast 192 11590 60
F34T12 Std. Magnetic Ballast 164 9500 58
F32T8/700 Magnetic 142 10640 75
FO32/800XP QTR4x32T8/120 ISN-SC 110 10080 92
E.S. Magnetic Ballast 86 5795 67
E.S. Magnetic Ballast 72 4750 66
E.S. Magnetic Ballast 172 11590 67
E.S. Magnetic Ballast 144 9500 66
Input
Input
50
SPECIFICATION DATA
LAMP
LAMP
Blue Blue
Red
BALLAST
Black White
Note: For one lamp application, cap any blue lead. Insulate to 600 volts.
QUICKTRONIC RESIDENTIAL 2x32
BALLAST
LAMP
LAMP
LAMP
LAMP
Black White
Yellow
Yellow
Red Red
Blue Blue
Note: For three lamp application, cap any unused blue lead. Insulate to 600 volts.
QUICKTRONIC RESIDENTIAL 4x32
Catalog # Date Type
Project Prepared by
Comments
Normal Ballast Factor
T8 INSTANT START
120V Residential Series
Electronic T8 Residential Series Fluorescent Systems (Residential Use Only) 120V
Input Rated Ballast Input System Item Current Lamp Lumens No. of Factor System Power Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens (W) (lm/W) BEF
QTR 2x32T8/120 ISN-SC 0.89 FO32/XP 3000 2 0.87 5220 55 95 1.58
49313
49314 Pallet Pack
49317
49318 Pallet Pack
Pallet Pack contains 840 pieces, (add “-PAL” to Description) 1: Ballast Efficiency Factor (BEF) = (Ballast Factor x 100) divided by Input Power
10-Pack
0.56 3000 1 1.03 3090 34 91 3.03
0.74 FO25/XP 2175 2 0.90 3915 45 87 2.00
0.49 2175 1 1.05 2285 28 82 3.75
0.54 FO17/XP 1375 2 0.93 2560 30 85 3.10
0.36 1375 1 1.07 1470 19 77 5.63
0.89 FBO32/XP 2900 2 0.87 5045 55 92 1.58
0.56 2900 1 1.03 2985 34 88 3.03
0.85 FBO31/XP 2775 2 0.88 4885 54 90 1.63
0.56 2775 1 1.03 2860 33 87 3.12
0.68 FO40/XP 3750 1 1.02 3825 40 96 2.55
QTR 4x32T8/120 ISN-SC 1.70 FO32/XP 3000 4 0.84 10080 110 92 0.76
10-Pack
1.46 3000 3 0.96 8640 92 94 1.04
1.38 FO25/XP 2175 4 0.88 7655 86 89 1.02
1.18 2175 3 1.00 6525 72 91 1.39
1.00 FO17/XP 1375 4 0.92 5060 60 84 1.53
0.87 1375 3 1.03 4250 51 83 2.02
1.71 FO40/XP 3750 3 0.91 10235 112 91 0.81
1.36 3750 2 1.09 8175 86 95 1.27
RESIDENTIAL USE ONLY – QTR electronic ballasts meet FCC consumer limits, have high THD (<200%) and normal power factor (>0.50), therefore are for residential use only and cannot be used in commercial applications.
Performance Guide
Data shown based upon SYLVANIA
®
OCTRON RESIDENTIAL T8 ballasts are also
1
compatible with other lamp manufac­turers equivalent lamp types that meet ANSI specifications.
All models will also operate F17, F25 and F32 (and the U-Bend equivalent) T8 lamps.
RESIDENTIAL USE ONLY
Starting Method: Instant Start Ballast Factor: Normal Circuit Type: Parallel Lamp Frequency: >40kHz Lamp CCF: Less than 1.7 Starting Temp:
Input Frequency: 60 Hz THD: <200% Normal Power Factor: >0.50 Voltage Range: ±10% of Rated Input
UL Listed Class P, Type 1 Outdoor CSA Certified (4L only) 70°C Max Case Temperature FCC 47CFR Part 18 Consumer Class A Sound Rating ANSI C62.41 Cat. A Transient Protection Remote Mounting (Max. wire length from ballast case to lampholder): up to 18 feet
2 Operation below 50°F (10°C) may affect
FO32 lamps. QUICKTRONIC
Specifications
Data based on F32T8 lamp
2
0°F for OCTRON®T8 lamps; 60°F for SUPERSAVER®T8 lamps
light output or lamp operation – see “Low Temp. Starting” definition.
®
NEW!
QTR T8 RES
Dimensions: Wiring:
Overall: 9.5" L x 1.68" W x 1.18" H Leads only Mounting: 8.90" (no connectors provided)
Product Weight:
1.6 lbs each (approx)
Item Number 49313 QTR 2 x 32T8 / 120 ISN-SC
QUICKTRONIC RESIDENTIAL
Number of Lamps
Specifications subject to change without notice.
Height
8.70 mm Slot
Width
For two lamp application, cap both unused blue leads &
one yellow lead individually. Insulate to 600 volts.
Mounting
Length
Length
Case Size
Starting/Ballast Factor
Line Voltage
Primary Lamp Wattage
Residential Ballast Warranty
QUICKTRONIC T8 RESIDENTIAL electronic ballasts are under warranty for 2 years. OSRAM SYLVANIA shall correct any defects, at our option, and replace any ballast determined to be defective under the terms of this warranty. Note: Labor costs are not reimbursed by OSRAM SYLVANIA.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
51
Loading...