Sylvania QTP T8 PSN DATASHEET

www.sylvania.com
QUICKTRONIC®PROStart®PSN T8 Universal Voltage
Professional Series
Normal Ballast Factor
Lamp / Ballast Guide
Primary Systems 32W T8
1-lamp QTP1x32T8/UNV PSN-TC 2-lamp QTP2x32T8/UNV PSN-TC 3-lamp QTP3x32T8/UNV PSN-SC 4-lamp QTP4x32T8/UNV PSN-SC
Also operates:
FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS, FBO30/SS (30W), FBO29/SS, FO28/SS (28W) & FO25/SS (25W)
Key System Features
• PROStart®Programmed Rapid Start
QTP T8 PSN
• Ideal for occupancy sensors
• NEMA Premium Ballast (NPB) Program compliant
• Low profile enclosures:
• 1.00" high “Thin Can”
• 1.18" high “Small Can”
• Min. Starting Temp:
• 0°F (-18°C) for T8 lamps
• 60°F (16°C) for Energy Saving
T8 lamps
• Operates at >40kHz to avoid inter­ference with infrared control systems
• Universal Input Voltage (120-277V)
Application Information
SYLVANIA QUICKTRONIC PROStart T8 is ideally suited for:
• Any applications where extended lamp life is required to reduce maintenance costs
• Energy retrofits
• Occupancy sensors
• Building control systems
SYLVANIA QUICKTRONIC PROStart
programmed rapid start electronic ballasts operate linear U-bend SUPERSAVER equivalent T8 lamps in applications where extended lamp life is required.
QUICKTRONIC PROStart ballasts utilize a micro-controller based circuit to apply a precise amount of cathode heat prior to starting the lamp. This ensures that the cathodes have reached optimum temper- ature before the lamp is started. Once the lamp has ignited, the ballast eliminates the cathode voltage which optimizes system efficiencies similar to instant start ballasts.
QUICKTRONIC PROStart ballasts are NEMA Premium Ballast (NPB) program compliant. The NPB program promotes the use of high efficiency T8 electronic ballasts by meeting or exceeding the Ballast Efficiency Factors, (BEF) established by the CEE, (Consortium for Energy Efficiency). For additional infor­mation on this program go to:
®
www.cee1.org or www.nema.org
System Information
QUICKTRONIC PROStart ballasts provide optimum starting conditions to provide over 100,000 switching cycles for occupancy sensor and building control system applications.
QUICKTRONIC PSN UNV operates from 120V through 277V, eliminating “wrong voltage” wiring errors and reducing the number of models in inventory by half.
In addition to substantial energy savings, QUICKTRONIC PSN ballasts deliver an optimized programmed start which extends lamp life. This advanced starting process drastically reduces the amount of cathode sputtering, resulting in improved lamp life in all applications including short start cycles.
QUICK 60+ when you use SYLVANIA lamps and ballasts together as a system. See the QUICK 60+ warranty bulletin for complete details.
The QUICKTRONIC PROStart ballasts are ideally suited for applications requiring extended lamp life. In short cycle applica­tions, our PROStart ballasts will deliver three times the number of start cycles compared to electronic Instant Start ballasts.
®
warranty coverage is included
All SYLVANIA Professional Series (QTP) electronic ballasts feature high power quality (<10% THD), lightweight, low profile designs.
This product is also offered in new banded packaging and pallet packs.
Lamp & Power Initial Initial System Light Energy Lamp Ballast Type (W) Lumens LPW Lumens Output Savings Life
2-FO32/700 QTP 2x32 ISN
2-FO32/800/XP QTP 2x32 ISN
2-FO32/800/XP QTP 2x32 PSN
2-FO28/SS QTP 2x32 PSN
45000
40000
35000
30000
25000
20000
Lamp Life (Hours)
15000
10000
5000
Input Mean Mean % %
59 4930 84 4435 Baseline Baseline Baseline
59 5280 89 4965 112% 0% 100%
59 5280 89 4965 112% 0% 150%
52 4800 92 4510 102% 12% 150%
OCTRON T8 Lamp Life Comparison
0
min
15
min Cont.
30
Distributor-friendly for easy stocking and individual ballast sales
• Reduced waste
• Easy removable bands
• No tangled wires
Relative
®
PROStart w/ XP, SS & XPS lamps
Instant Start w/ XP, SS & XPS lamps
Instant Start w/ 700 Series T8 lamps
1 hr 3 hr 12 hr
Start Cycle
36
SPECIFICATION DATA
Black/White
White
Red Red
Blue Blue
LAMP
TC
Black
White Yellow Yellow
Red Red Blue Blue
LAMP
LAMP
TC
Blue/White
Yellow Yellow
Red Red
LAMP 2
Blue/White
Blue
Blue
LAMP 1
LAMP 3
LAMP 4
Brown Brown
SC
Black White
Blue/White
Yellow Yellow
Red Red
LAMP 2
Blue/White
Blue
Blue
LAMP 1
LAMP 3
SC
Black White
Catalog # Date Type
Project Prepared by
Comments
Normal Ballast Factor
T8 PROStart
®
PSN UNV
Professional Series
PROStart®Programmed Rapid Start Systems Universal Voltage (120-277V)
Item OSRAM SYLVANIA Current Lamp Lumens No. of Factor System Mean Wattage Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF
51399
51400 10-Pack
51401 Pallet Pack
51402
51405 10-Pack
51406 Pallet Pack
51403
51410 10-Pack
51411 Pallet Pack
51404
51415 10-Pack
51416 Pallet Pack
Banded Pack, (add “-B” to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add “-PAL” to Description). 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value).
QTP 1x32T8/UNV PSN-TC 0.26/0.11 FO32/700 2800 1 0.88 2465 2220 31/30 79/82 2.93
Banded Pack
QTP 2x32T8/UNV PSN-TC
Banded Pack
QTP 3x32T8/UNV PSN-SC
Banded Pack
QTP 4x32T8/UNV PSN-SC
Banded Pack
1 lamp
Input Rated Ballast Input System
0.26/0.11 FO32/XP 3000 1 0.88 2640 2480 31/30 85/88 2.93
0.24/0.10 FO30/SS 2850 1 0.88 2510 2360 29/28 87/90 3.14
0.23/0.09 FO28/SS 2725 1 0.88 2400 2255 27/26 89/92 3.38
0.20/0.09 FO25/SS 2475 1 0.88 2175 2045 24/23 91/95 3.83
0.50/0.21 FO32/700 2800 2 0.88 4930 4435 59/56 84/88 1.57
0.50/0.21 FO32/XP 3000 2 0.88 5280 4965 59/56 89/94 1.57
0.47/0.20 FO30/SS 2850 2 0.88 5015 4715 55/53 91/95 1.66
0.45/0.19 FO28/SS 2725 2 0.88 4800 4510 52/49 92/98 1.80
0.39/0.17 FO25/SS 2475 2 0.88 4355 4095 46/44 95/99 2.00
0.74/0.31 FO32/700 2800 3 0.88 7390 6655 88/85 84/87 1.04
0.74/0.31 FO32/XP 3000 3 0.88 7920 7445 88/85 90/93 1.04
0.70/0.29 FO30/SS 2850 3 0.88 7525 7075 83/80 91/94 1.10
0.65/0.27 FO28/SS 2725 3 0.88 7195 6760 77/75 93/96 1.17
0.58/0.25 FO25/SS 2475 3 0.88 6535 6140 69/68 95/96 1.29
0.99/0.41 FO32/700 2800 4 0.88 9855 8870 118/113 83/87 0.78
0.99/0.41 FO32/XP 3000 4 0.88 10,560 9925 118/113 90/94 0.78
0.93/0.39 FO30/SS 2850 4 0.88 10,030 9430 111/106 90/95 0.83
0.88/0.36 FO28/SS 2725 4 0.88 9590 9015 104/99 92/97 0.89
0.77/0.32 FO25/SS 2475 4 0.88 8710 8190 92/90 95/97 0.98
2 lamp
4 lamp3 lamp
Performance Guide
Data based upon SYLVANIA OCTRON lamps shown. QUICKTRONIC®QTP PROStart ballasts are also compatible
1
with other lamp manufacturers equiv­alent lamp types that meet ANSI specifi­cations. QTP PROStart ballasts will also operate F17 & F25, SUPERSAVER U-Bend equivalent T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Ballast Technology & Specification Guide.
Specifications
Starting Method: Programmed
Rapid-Start
Ballast Factor: 0.88 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.6 Starting Temp:
0°F (-18°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER
Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V
UL Listed Class P, Type 1, Outdoor CSA Certified 70°C Max Case Temp. FCC 47CFR Part 18 Non-Consumer Class A Sound Rating NEMA Ballast Program compliant ANSI C62.41 Cat A. Transient GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lamp holder):
• 20 ft: full wattage T8s
• 10 ft: energy saving T8s
• 4 ft: 25W energy saving T8s (keep blue wires short, ie. lamp(s) attached to the blue leads to remain in the fixture that houses the ballast).
2 Operation below 50ºF (10°C) may affect
light output or lamp operation – see “Low Temp. Starting” definition.
2
rated line (108-305V)
®
®
&
Data based on F32T8
®
T8 lamps
QTP T8 PSN
Dimensions “TC & SC” Enclosure:
“SC” Overall: 9.5" L x 1.68" W x 1.18" H “TC” Overall: 9.5" L x 1.68" W x 1.00" H Mounting: 8.90" Weight: 1.6 lbs each
Item Number 51402 QTP 2 x 32T8 / UNV PSN TC
QUICKTRONIC PROFESSIONAL
Number of Lamps (1, 2, 3, 4)
Primary Lamp Type (F32T8)
Specifications subject to change without notice.
Height
8.70 mm Slot
Width
Mounting
Length
Length
Wiring:
Leads only (no connectors provided)
Enclosure Type (TC or SC)
Starting Type/Ballast Factor – PROStart/Normal BF
Line Voltage (120-277V)
System Life / Warranty
QUICKTRONIC products are covered by our QUICK 60+®warranty, a compre­hensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
37
Loading...