Sylvania PSX T8 XPS DATASHEET

www.sylvania.com
QUICKTRONIC®PROStart®PSX T8 Universal Voltage
High Efficiency Series
Lamp / Ballast Guide
Primary Systems 32W T8
1-lamp QTP1x32T8/UNV PSX-TC 2-lamp QTP2x32T8/UNV PSX-TC 3-lamp QTP3x32T8/UNV PSX-SC 4-lamp QTP4x32T8/UNV PSX-SC
PSX T8 XPS
Also operates:
FBO32, FBO31, FO25, FBO24, FO17, FBO16, FO30/SS, FBO30/SS (30W), FBO29/SS, FO28/SS (28W) & FO25/SS (25W)
Key System Features
• High Efficiency systems – over 90% efficient
• PROStart PSX Xtreme Ballast Programmed Rapid Start
• Universal input voltage (120-277V)
• Min. Starting Temp:
• 0°F (18°C) for T8 lamps
• 60°F (16°C) for Energy Saving
T8 lamps
• Low profile enclosures
1.00" high “Thin Can”
1.18" high “Small Can”
• Operates at >40kHz to avoid inter­ference with infrared control systems
Application Information
SYLVANIA QUICKTRONIC PROStart Ballasts
are ideally suited for:
• Any application where maximum lamp life is required to reduce maintenance costs
• Energy retrofits
• Occupancy sensors
• Building control systems
SYLVANIA QUICKTRONIC PROStart PSX
programmed rapid start electronic ballasts are specifically designed to be combined with the OCTRON XPS high performance T8 lamps.
The extra low (0.71) ballast factor PROStart ballast combined with the high lumen output OCTRON XPS T8 lamps deliver similar light output compared to a standard 700 series T8/88% BF system while saving up to 20% in energy.
Compared to typical ES T12/Magnetic lighting systems, SYLVANIA Xtreme Systems will deliver comparable light output while saving over 35% in energy.
In addition to substantial energy savings, QUICKTRONIC Xtreme delivers an optimized programmed start which extends OCTRON XPS lamp life.
System Information
SYLVANIA QUICKTRONIC High Efficiency PROStart System advantages:
• Operate from 120V through 277V
• Eliminates “wrong voltage” errors
• Reduces inventory by 50%
• Utilizes Programmed Rapid Start operation for:
• Highest System Efficacy
• Longer Life
• Over 100,000 switching cycles for occupancy sensor and building control systems applications with OCTRON XPS T8 lamps
• Operate at >40kHz to reduce potential interference with infrared control systems
• Very low harmonic distortion (<10%)THD
QUICK 60+®warranty coverage is included when you use SYLVANIA lamps and ballasts together as a system. See the QUICK 60+ warranty bulletin for complete details.
Xtreme Systems
29% Energy Savings
71%
®
XPS®Lamps
Relative
% Relative Light Output
% Energy Savings
104%
35% Energy Savings
65%
2-FO32/XPS
QTP 2x32 PSX
OCTRON
All SYLVANIA Professional Series (QTP)
This advanced starting process drastically reduces the amount of cathode sputtering, resulting in improved lamp life in all appli­cations.
Lamp & Power System Initial System Light Energy Ballast Type (W) Lumens LPW Lumens Output Savings
2-F34T12 E.S. Magnetic Ballast
2-FO32/700 QTP 2x32 ISN
2-FO32/800/XP QTP 2x32 ISL
2-FO32/800/XPS QTP 2x32 PSX
110%
100% 100%
100%
90%
80%
70%
60%
50%
40%
2-F34T12
E.S. Mag. Ballast
Input Mean Mean %
72 4665 65 3965 Baseline Baseline
59 4930 84 4435 112% 18%
51 4680 92 4400 111% 29%
47 4400 94 4140 104% 35%
112%
18% Energy Savings
82%
2-FO32/700
QTP 2x32 ISN
electronic ballasts feature high power quality (<10% THD), lightweight, low profile designs.
This product is also offered in new banded packaging and pallet packs.
111%
2-FO800/XP
QTP 2x32 ISL
32
SPECIFICATION DATA
Black/White
White
Red Red
Blue Blue
LAMP 1
TC
Black
White Yellow Yellow
Red Red Blue Blue
LAMP 1
LAMP 2
TC
Blue/White
Yellow Yellow
Red Red
LAMP 2
Blue/White
Blue
Blue
LAMP 1
LAMP 3
LAMP 4
Brown Brown
SC
Black White
Blue/White
Yellow Yellow
Red Red
LAMP 2
Blue/White
Blue
Blue
LAMP 1
LAMP 3
SC
Black White
Catalog # Date Type
Project Prepared by
Comments
Low Ballast Factor
T8 PROStart
®
PSX
High Efficiency
Xtreme Systems: PSX Ballast & XPS Lamps Universal Voltage (120-277V)
Input Rated Ballast Input System Item OSRAM SYLVANIA Current Lamp Lumens No. of Factor System Mean Power Efficacy Number Description (AMPS) Type (lm) Lamps (BF) Lumens Lumens (W) (lm/W) BEF
QTP 1x32T8/UNV PSX-TC
51224
Banded Pack
51420 10-Pack
51421 Pallet Pack
QTP 2x32T8/UNV PSX-TC
51225
Banded Pack
51425 10-Pack
51426 Pallet Pack
QTP 3x32T8/UNV PSX-SC
51226
Banded Pack
51430 10-Pack
51431 Pallet Pack
QTP 4x32T8/UNV PSX-SC
51227
Banded Pack
51435 10-Pack
51436 Pallet Pack
Banded Pack, (add “-B” to Description). Banded Pack and 10-Pack contain 10 pieces each. Pallet Pack contains 840 pieces, (add “-PAL” to Description) 1: Ballast Efficiency Factor (BEF) shown = (Ballast Factor x 100) divided by Input Power (Note: calculation based on lowest wattage value).
1 lamp
Dimensions “TC & SC” Enclosure:
“SC” Overall: 9.5" L x 1.68" W x 1.18" H “TC” Overall: 9.5" L x 1.68" W x 1.00" H Mounting: 8.90" Weight: 1.6 lbs each
Item Number 51225 QTP 2 x 32T8 / UNV PSX - TC
QUICKTRONIC PROFESSIONAL
Number of Lamps
Primary Lamp Type (F32T8)
Specifications subject to change without notice.
Wiring/Packaging Configurations: 1, 2, 3 and 4 lamp “TC & SC” models: Wiring – Leads only (No connectors provided)
0.21/0.09 FO32/700 2800 1 0.71 1990 1790 25 80 2.84
0.21/0.09 FO32/XPS 3100 1 0.71 2200 2070 25 88 2.84
0.40/0.17 FO32/700 2800 2 0.71 3975 3580 47/46 85/86 1.54
0.40/0.17 FO32/XPS 3100 2 0.71 4400 4140 47/46 94/96 1.54
0.59/0.25 FO32/700 2800 3 0.71 5965 5370 73/71 82/84 1.00
0.59/0.25 FO32/XPS 3100 3 0.71 6600 6205 73/71 90/93 1.00
0.78/0.33 FO32/700 2800 4 0.71 7950 7155 93/91 85/87 0.78
0.78/0.33 FO32/XPS 3100 4 0.71 8800 8275 93/91 95/96 0.78
2 lamp
4 lamp3 lamp
Mounting
Length
Length
Enclosure Type (TC or SC)
Starting Type/Ballast Factor - PROStart/Xtreme BF
Line Voltage (120-277V)
Height
8.70 mm Slot
Width
Performance Guide
Data shown based upon SYLVANIA OCTRON®lamps shown. QTP PROStart PSX is also compatible with other lamp
1
manufacturers equivalent lamp types that meet ANSI specifications. QTP PROStart ballasts will also operate F17 & F25, SUPERSAVER®& U-Bend equiv­alent T8 lamps. Complete performance data is available in the QUICKSYSTEMS section of the SYLVANIA Ballast Technology & Specification Guide.
Specifications
Data based on FO32T8/XPS
Starting Method: Programmed
Rapid Start
Ballast Factor: 0.71 Circuit Type: Series Lamp Frequency: >40 kHz Lamp CCF: Less than 1.6 Starting Temp:
2
0°F (-18°C) for OCTRON T8 lamps; 60°F (16°C) for SUPERSAVER®T8 lamps
Input Frequency: 50/60 Hz Low THD: <10% Power Factor: >98% Voltage Range: ±10% of 120-277V
rated line (108-305V)
UL Listed Class P, Type 1 Outdoor CSA Certified 70°C Max Case Temp. FCC 47CFR Part 18 Non-Consumer Class A Sound Rating ANSI C62.41 Cat A. Transient GFCI compatible Emergency ballast compatible Remote Mounting (Max. wire length from ballast case to lampholder):
• 20 ft: full wattage T8s
• 10 ft: energy saving T8s
• 4 ft: 25W energy saving T8s (keep blue wires short, ie. lamp(s) attached to the blue leads to remain in the fixture that houses the ballast).
2 Operation below 50ºF (10°C) may affect
light output or lamp operation – see “Low Temp. Starting” definition.
System Life / Warranty
QUICKTRONIC products are covered by our QUICK 60+ comprehensive lamp and ballast system warranty. For additional details, refer to our QUICK 60+ warranty bulletin.
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828) www.sylvania.com
®
warranty, a
PSX T8 XPS
33