63
OSRAM SYLVANIA National Customer Service and Sales Center
1-800-LIGHTBULB (1-800-544-4828)
www.sylvania.com
Starting Method: Programmed
Start
Circuit Type: Series
Lamp Frequency: > 40 KHz
Lamp CCF: Less than 1.7
Starting Temp: 50°F minimum
Input Frequency: 60 Hz
Low THD: < 10%
Power Factor: > 98%
Voltage Range: +/–10% of
Rated Input
UL Listed Class P, Type 1 Outdoor
CSA Certified
70°C Max Case Temperature
FCC 47CFR Part 18 Non-Consumer
Class A Sound Rating
ANSI C62.41 Cat. A Transient Protection
Dynamic End-of-Lamp-Life Sensing
Remote Mounting up to 7 feet
.1Data based on PENTRON HO lamp type. See the
SYLVANIA QUICKTRONIC Electronic Ballast Technology
and Specification Guide (ECS-ELECTRONIC) for other
lamp combinations.
Performance Guide
Specifications
1
Ordering Guide
System Life / Warranty
<10% THD Electronic T5 HO Fluorescent Dimming Systems
Dimensions:
Overall: 425mm L x 30mm W x 30mm H
Mounting: 415 mm
Wiring:
Push-in connectors (no leads provided)
Use 18AWG solid copper wire only
Packaging:
Quantity: 20
Weight: 1.0 lbs ea. (approx)
Input Input Rated
2,3
Ballast
3
Input3System
Item Voltage Current Lamp1Lumens No. of Factor System3Wattage Efficacy
Number Description (VAC) (AMPS) Type (lm) Lamps (BF) Lumens (W) (lm/W)
49671 QT1x54/120PHO-DIM 120 0.54 FP54T5HO 5000 1 1.00 5000 62 81
0.01 50 8
49672 QT1x54/277PHO-DIM 277 0.23 FP54T5HO 5000 1 1.00 5000 61 82
0.01 50 8
49673 QT2x54/120PHO-DIM 120 1.07 FP54T5HO 5000 2 1.00 10000 120 83
0.01 100 18
49674 QT2x54/277PHO-DIM 277 0.45 FP54T5HO 5000 2 1.00 10000 117 85
0.01 100 18
1
Also compatible with other manufacturer’s equivalent lamp types that meet ANSI standards.
2
Rated lamp lumens and performance data based on PENTRON®HO lamps.
3
At 35°C lamp ambient temperature
Item Number 49673 QT 2 x 54 / 120 PHO-DIM System Type – PHO-DIM
QUICKTRONIC Line Voltage
Number of Lamps (1, 2) Primary Lamp Wattage
Dimming Control
Specifications
2
Specifications subject to change
without notice.
QUICKTRONIC products are covered by
our QUICK 60+
®
warranty, a comprehensive lamp and ballast system
warranty. For additional details, refer
to our QUICK 60+ warranty bulletin.
Dimming Control2: 1-10Vdc
two wire control (10V = full output,
1V = minimum output)
Line Voltage Protection:
Ballast goes to 90% if line voltage is
inadvertently applied to control leads.
Ballast will source up to 0.5mA for
control purposes. May be wired as
Class 1 or Class 2 circuit.
QUICKTRONIC HELIOS ballasts are
compatible with a wide range of
0–10V controllers available from
various manufacturers. A list of
controls companies is on pages
64-65. (Controls list literature
ordering code ECS041.)