SKORPION™ Process Air Heater

SKORPION ™ Model
F075615 1.5kW 120V 1PH 12.5A
F075616 3.0kW 240V 1PH 12.5A
Only qualified individuals should install this heater and related controls. Follow all applicable electrical codes and use proper wiring.
BURN HAZARD!
Avoid contact with the heater nozzle during or soon after operation.
EXPLOSION HAZARD! Heater produces extremely high temperatures. Do not use in hazardous environments, and/or near explosive or reactive gases, or combustible materials.
OSRAM SYLVANIA 131 Portsmouth Avenue Exeter, NH 03833 USA Tel: 603-772-4331
Fax: 603-772-1072
SHOCK HAZARD!
1
OPERATING INSTRUCTIONS
6/18/07
Warranty
OSRAM SYLVANIA warrants that all products to be delivered hereunder will be free from defects in material and workmanship at the time of delivery. OSRAM SYLVANIA's obligation under this warranty shall be limited to (at its option) repairing, replacing, or granting a credit at the prices invoiced at the time of shipment for any of said products. This warranty shall not apply to any such products which shall have been repaired or altered, except by OSRAM SYLVANIA, or which shall have been subjected to physical or electrical abuse or misuse. OSRAM SYLVANIA shall be liable under this warranty only if (A) OSRAM SYLVANIA receives notice of the alleged defect within sixty (60) days after the date of shipment; (B) the adjustment procedure hereinafter provided is followed, and (C) such products are, to OSRAM SYLVANIA’s satisfaction, determined to be defective.
THE WARRANTY SET FORTH IN THE PRECEDING PARAGRAPH IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE OR OF MERCHANTABILITY.
The information contained in this manual is based on data considered to be true and accurate. Reasonable precautions for accuracy has been taken in the preparation of this manual, however OSRAM SYLVANIA assumes no responsibility for any omissions or errors, nor assumes any liability for damages that may result from the use of the product in accordance with the information contained in this manual.
Please direct all warranty/repair requests or inquiries to the place of purchase, and provide the following information, in writing:
(A) Order number under which products were shipped (B) Model/Serial Number of product (C) Reason for rejection
PRODUCTS CAN NOT BE RETURNED TO OSRAM SYLVANIA WITHOUT AUTHORIZATION.
Replacement, repair, or credit for products found to be defective will be made by the place of purchase. All products found to be not defective will be returned to the Buyer; transportation charges collect or stored at Buyers expense.
OSRAM SYLVANIA 131 Portsmouth Avenue Exeter, NH 03833 USA Tel: 603-772-4331
Fax: 603-772-1072
2
OPERATING INSTRUCTIONS
6/18/07

Overview

The SKORPION ™ Process Air Heater from OSRAM SYLVANIA represents the perfect combination of power, size, reliability and control in Air Heating technology.
With a closed-loop PID temperature control system, the SKORPION ™ produces air temperatures from 1200°F (650°C) (120V version) to 1400°F (760°C) (240V version), to ensure precise control of your process.
If used correctly, an element life of 5000 hours or greater can be expected.

Operation

1. Turn SKORPION air heater ON using two switches
1.1. Switch S1 (blower) sends power to the blower and to heater switch S2.
1.2. Switch S2 (heater) sends power to the heater control circuit.
1.3. Note, for heater safety, S2 (heater) cannot turn ON without S1 (blower) ON.
2. Adjust airflow via a rotational air damper at the blower inlet.
3. Adjust set point (SV) with the UP/DOWN arrows on the temperature controller. Heater will ramp to temperature.
3.1. The set point temperature (SV) is in GREEN.
3.2. The process temperature (PV) is in RED.
3.3. The process temperature is measured with an internal type “K” thermocouple located at
the end of an element inside the stainless housing.
:
OSRAM SYLVANIA 131 Portsmouth Avenue Exeter, NH 03833 USA Tel: 603-772-4331