Proper service and repair is important to the safe, reliable operation of all
Funai Equipment. The service procedures recommended by Funai and
described in this service manual are effective methods of performing
service operations. Some of these service special tools should be used
when and as recommended.
It is important to note that this service manual contains various CAUTIONS
and NOTICES which should be carefully read in order to minimize the risk
of personal injury to service personnel. The possibility exists that improper
service methods may damage the equipment. It also is important to
understand that these CAUTIONS and NOTICES ARE NOT EXHAUSTIVE.
Funai could not possibly know, evaluate and advice the service trade of all
conceivable ways in which service might be done or of the possible
hazardous consequences of each way. Consequently, Funai has not
undertaken any such broad evaluation. Accordingly, a servicer who uses a
service procedure or tool which is not recommended by Funai must first
use all precautions thoroughly so that neither his safety nor the safe
operation of the equipment will be jeopardized by the service method
selected.
1. All Items are measured without pre-emphasis unless otherwise specified.
2. Power supply: AC 120 V, 60 Hz
3. Ambient Temperature: +25 °C
1-1-1E6161SP
LASER BEAM SAFETY PRECAUTIONS
This DVD player uses a pickup that emits a laser beam.
Do not look directly at the laser beam coming
from the pickup or allow it to strike against your
skin.
The laser beam is emitted from the location shown in the figure. When checking the laser diode, be sure to keep
your eyes at least 30 cm away from the pickup lens when the diode is turned on. Do not look directly at the laser
beam.
CAUTION: Use of controls and adjustments, or doing procedures other than those specified herein, may result in
hazardous radiation exposure.
Drive Mechanism Assembly (within the DVD Mechanism)
Laser Beam Radiation
Laser Pickup
Turntable
Location: Top of DVD mechanism.
CAUTION
LASER RADIATION
WHEN OPEN. DO NOT
STARE INTO BEAM.
1-2-1E61S0LSP
IMPORTANT SAFETY PRECAUTIONS
Product Safety Notice
Some electrical and mechanical parts have special
safety-related characteristics which are often not
evident from visual inspection, nor can the protection
they give necessarily be obtained by replacing them
with components rated for higher voltage, wattage,
etc. Parts that have special safety characteristics are
identified by a # on schematics and in parts lists. Use
of a substitute replacement that does not have the
same safety characteristics as the recommended
replacement part might create shock, fire, and/or other
hazards. The Product’s Safety is under review
continuously and new instructions are issued
whenever appropriate. Prior to shipment from the
factory, our products are carefully inspected to confirm
with the recognized product safety and electrical
codes of the countries in which they are to be sold.
However, in order to maintain such compliance, it is
equally important to implement the following
precautions when a set is being serviced.
Precautions during Servicing
A. Parts identified by the # symbol are critical for
safety. Replace only with part number specified.
B. In addition to safety, other parts and assemblies
are specified for conformance with regulations
applying to spurious radiation. These must also be
replaced only with specified replacements.
Examples: RF converters, RF cables, noise
blocking capacitors, and noise blocking filters, etc.
C. Use specified internal wiring. Note especially:
1) Wires covered with PVC tubing
2) Double insulated wires
3) High voltage leads
D. Use specified insulating materials for hazardous
live parts. Note especially:
1) Insulation tape
2) PVC tubing
3) Spacers
4) Insulators for transistors
E. When replacing AC primary side components
(transformers, power cord, etc.), wrap ends of
wires securely about the terminals before
soldering.
F.Observe that the wires do not contact heat
producing parts (heat sinks, oxide metal film
resistors, fusible resistors, etc.).
G. Check that replaced wires do not contact sharp
edges or pointed parts.
H. When a power cord has been replaced, check that
5 - 6 kg of force in any direction will not loosen it.
I.Also check areas surrounding repaired locations.
J. Be careful that foreign objects (screws, solder
droplets, etc.) do not remain inside the set.
K. Crimp type wire connector
The power transformer uses crimp type
connectors which connect the power cord and the
primary side of the transformer. When replacing
the transformer, follow these steps carefully and
precisely to prevent shock hazards.
Replacement procedure
1) Remove the old connector by cutting the wires
at a point close to the connector.
Important: Do not re-use a connector.
(Discard it.)
2) Strip about 15 mm of the insulation from the
ends of the wires. If the wires are stranded,
twist the strands to avoid frayed conductors.
3) Align the lengths of the wires to be connected.
Insert the wires fully into the connector.
4) Use a crimping tool to crimp the metal sleeve at
its center. Be sure to crimp fully to the complete
closure of the tool.
L. When connecting or disconnecting the internal
connectors, first, disconnect the AC plug from the
AC outlet.
1-3-1DVDN_ISP
Safety Check after Servicing
Examine the area surrounding the repaired location for damage or deterioration. Observe that screws, parts, and
wires have been returned to their original positions. Afterwards, do the following tests and confirm the specified
values to verify compliance with safety standards.
1. Clearance Distance
When replacing primary circuit components, confirm
specified clearance distance (d) and (d’) between
soldered terminals, and between terminals and
surrounding metallic parts. (See Fig. 1)
Table 1: Ratings for selected area
Chassis or Secondary Conductor
Primary Circuit Terminals
AC Line VoltageClearance Distance (d), (d’)
120 V≥ 3.2 mm (0.126 inches)
Note: This table is unofficial and for reference only. Be
sure to confirm the precise values.
2. Leakage Current Test
Confirm the specified (or lower) leakage current
between B (earth ground, power cord plug prongs) and
externally exposed accessible parts (RF terminals,
antenna terminals, video and audio input and output
terminals, microphone jacks, earphone jacks, etc.) is
lower than or equal to the specified value in the table
below.
Measuring Method (Power ON):
Insert load Z between B (earth ground, power cord plug
prongs) and exposed accessible parts. Use an AC
voltmeter to measure across the terminals of load Z.
See Fig. 2 and the following table.
dd'
Fig. 1
Exposed Accessible Part
Z
AC Voltmeter
(High Impedance)
Earth Ground
B
Power Cord Plug Prongs
Table 2: Leakage current ratings for selected areas
AC Line VoltageLoad ZLeakage Current (i)Earth Ground (B) to:
120 V
Note: This table is unofficial and for reference only. Be sure to confirm the precise values.
0.15 µF CAP. & 1.5 kΩ RES.
Connected in parallel
i ≤ 0.5 mA PeakExposed accessible parts
1-3-2DVDN_ISP
Fig. 2
STANDARD NOTES FOR SERVICING
Circuit Board Indications
1. The output pin of the 3 pin Regulator ICs is
indicated as shown.
Top View
Out
2. For other ICs, pin 1 and every fifth pin are
indicated as shown.
Pin 1
3. The 1st pin of every male connector is indicated as
shown.
Pin 1
Input
In
Bottom View
5
10
Pb (Lead) Free Solder
When soldering, be sure to use the Pb free solder.
How to Remove / Install Flat Pack-IC
1. Removal
With Hot-Air Flat Pack-IC Desoldering Machine:
1. Prepare the hot-air flat pack-IC desoldering
machine, then apply hot air to the Flat Pack-IC
(about 5 to 6 seconds). (Fig. S-1-1)
Fig. S-1-1
Instructions for Connectors
1. When you connect or disconnect the FFC (Flexible
Foil Connector) cable, be sure to first disconnect
the AC cord.
2. FFC (Flexible Foil Connector) cable should be
inserted parallel into the connector, not at an
angle.
FFC Cable
Connector
CBA
* Be careful to avoid a short circuit.
2. Remove the flat pack-IC with tweezers while
applying the hot air.
3. Bottom of the flat pack-IC is fixed with glue to the
CBA; when removing entire flat pack-IC, first apply
soldering iron to center of the flat pack-IC and heat
up. Then remove (glue will be melted). (Fig. S-1-6)
4. Release the flat pack-IC from the CBA using
tweezers. (Fig. S-1-6)
CAUTION:
1. The Flat Pack-IC shape may differ by models. Use
an appropriate hot-air flat pack-IC desoldering
machine, whose shape matches that of the Flat
Pack-IC.
2. Do not supply hot air to the chip parts around the
flat pack-IC for over 6 seconds because damage
to the chip parts may occur. Put masking tape
around the flat pack-IC to protect other parts from
damage. (Fig. S-1-2)
1-4-1DVDN_SN
3. The flat pack-IC on the CBA is affixed with glue, so
be careful not to break or damage the foil of each
pin or the solder lands under the IC when
removing it.
With Soldering Iron:
1. Using desoldering braid, remove the solder from
all pins of the flat pack-IC. When you use solder
flux which is applied to all pins of the flat pack-IC,
you can remove it easily. (Fig. S-1-3)
CBA
Masking
Tape
Tweezers
Hot-air
Flat Pack-IC
Desoldering
Machine
Flat Pack-IC
Fig. S-1-2
Flat Pack-IC
Desoldering Braid
Soldering Iron
Fig. S-1-3
2. Lift each lead of the flat pack-IC upward one by
one, using a sharp pin or wire to which solder will
not adhere (iron wire). When heating the pins, use
a fine tip soldering iron or a hot air desoldering
machine. (Fig. S-1-4)
Sharp
Pin
Fine Tip
Soldering Iron
3. Bottom of the flat pack-IC is fixed with glue to the
CBA; when removing entire flat pack-IC, first apply
soldering iron to center of the flat pack-IC and heat
up. Then remove (glue will be melted). (Fig. S-1-6)
4. Release the flat pack-IC from the CBA using
tweezers. (Fig. S-1-6)
Fig. S-1-4
1-4-2DVDN_SN
With Iron Wire:
1. Using desoldering braid, remove the solder from
all pins of the flat pack-IC. When you use solder
flux which is applied to all pins of the flat pack-IC,
you can remove it easily. (Fig. S-1-3)
2. Affix the wire to a workbench or solid mounting
point, as shown in Fig. S-1-5.
3. While heating the pins using a fine tip soldering
iron or hot air blower, pull up the wire as the solder
melts so as to lift the IC leads from the CBA
contact pads as shown in Fig. S-1-5.
4. Bottom of the flat pack-IC is fixed with glue to the
CBA; when removing entire flat pack-IC, first apply
soldering iron to center of the flat pack-IC and heat
up. Then remove (glue will be melted). (Fig. S-1-6)
5. Release the flat pack-IC from the CBA using
tweezers. (Fig. S-1-6)
Note: When using a soldering iron, care must be
taken to ensure that the flat pack-IC is not
being held by glue. When the flat pack-IC is
removed from the CBA, handle it gently
because it may be damaged if force is applied.
Hot Air Blower
2. Installation
1. Using desoldering braid, remove the solder from
the foil of each pin of the flat pack-IC on the CBA
so you can install a replacement flat pack-IC more
easily.
2. The “●” mark on the flat pack-IC indicates pin 1.
(See Fig. S-1-7.) Be sure this mark matches the 1
on the PCB when positioning for installation. Then
presolder the four corners of the flat pack-IC. (See
Fig. S-1-8.)
3. Solder all pins of the flat pack-IC. Be sure that
none of the pins have solder bridges.
Example :
Pin 1 of the Flat Pack-IC
is indicated by a " " mark.
Fig. S-1-7
To Solid
Mounting Point
CBA
Tweezers
Iron Wire
Soldering Iron
Fig. S-1-5
Fine Tip
Soldering Iron
Flat Pack-IC
or
Presolder
Flat Pack-IC
CBA
Fig. S-1-8
Fig. S-1-6
1-4-3DVDN_SN
Instructions for Handling Semiconductors
Electrostatic breakdown of the semi-conductors may
occur due to a potential difference caused by
electrostatic charge during unpacking or repair work.
1. Ground for Human Body
Be sure to wear a grounding band (1 MΩ) that is
properly grounded to remove any static electricity that
may be charged on the body.
2. Ground for Workbench
Be sure to place a conductive sheet or copper plate
with proper grounding (1 MΩ) on the workbench or
other surface, where the semi-conductors are to be
placed. Because the static electricity charge on
clothing will not escape through the body grounding
band, be careful to avoid contacting semi-conductors
with your clothing.
<Incorrect>
<Correct>
1MΩ
CBA
Grounding Band
1MΩ
CBA
Conductive Sheet or
Copper Plate
1-4-4DVDN_SN
CABINET DISASSEMBLY INSTRUCTIONS
1. Disassembly Flowchart
This flowchart indicates the disassembly steps to gain
access to item(s) to be serviced. When reassembling,
follow the steps in reverse order. Bend, route, and
dress the cables as they were originally.
[1] Top Cover[2] Bottom Cover
[3] Front Assembly
[4] Reinforce Plate[5] Front Bracket
[6] DVD Main CBA Unit
[7] DVD Mechanism
[8] AV CBA
2. Disassembly Method
ID/
Loc.
No.
[1]Top CoverD1 2(S-1)---
[2]
[3]
[4]
[5]
[6]
[7]
Part
Bottom
Cover
Front
Assembly
Reinforce
Plate
Front
Bracket
DVD Main
CBA Unit
DVD
Mechanism
Fig.
No.
D1 2(S-2)---
D2 *6(L-1)---
D2 2(S-3)---
D2 2(S-4)---
(S-5A), (S-5B),
*CN201, *CN301,
D3
*CN401, *CN601,
*CN801
D3 4(S-6)2
Removal
Remove/*Unhook/
Unlock/Release/
Unplug/Desolder
Note
1
[8]AV CBAD4 (S-7), 4(S-8), *3(L-2)---
↓
(1)
Note:
(1) Identification (location) No. of parts in the figures
(2) Name of the part
(3) Figure Number for reference
(4) Identification of parts to be removed, unhooked,
unlocked, released, unplugged, unclamped, or
desoldered.
P = Spring, L = Locking Tab, S = Screw,
CN = Connector
* = Unhook, Unlock, Release, Unplug, or Desolder
e.g. 2(S-2) = two Screws (S-2),
2(L-2) = two Locking Tabs (L-2)
(5) Refer to “Reference Notes.”
↓
(2)
↓
(3)
↓
(4)
↓
(5)
About tightening screws
When tightening screws, tighten them with the
following torque.
1. CAUTION 1: Electrostatic breakdown of the laser
diode in the optical system block may occur as a
potential difference caused by electrostatic charge
accumulated on cloth, human body etc., during
unpacking or repair work.
To avoid damage of pickup follow next procedures.
1) Short the three short lands of FPC cable with
solder before removing the FFC cable (CN201)
from it. If you disconnect the FFC cable
(CN201), the laser diode of pickup will be
destroyed. (Fig. D3)
2) Disconnect Connectors (CN301), (CN401),
(CN601) and (CN801). Remove two Screws
(S-5A) and (S-5B) and lift the DVD Main CBA
Unit. (Fig. D3)
2. CAUTION 2: When reassembling, confirm the
FFC cable (CN201) is connected completely. Then
remove the solder from the three short lands of
FPC cable. (Fig. D3)
3. How to eject a disc in emergency
Press and hold [EJECT] on the unit for more than
5 seconds.
[1] Top Cover
(S-1)
(S-2)
[2] Bottom Cover
[4] Reinforce
Plate
(S-4)
[5] Front
Bracket
(L-1)
(S-2)
Fig. D1
(S-3)
(S-4)
(L-1)
[3] Front
Assembly
(L-1)
Fig. D2
1-5-2E61S0DC
[6] DVD Main
CBA Unit
[7] DVD Mechanism
(S-6)
CN201
(S-6)
(S-5B)
CN301
A
(S-6)
CN801
CN401
(S-5A)
CN601
[8] AV CBA
(S-7)
(S-8)
(L-2)
(L-2)
Fig. D4
Short the three short lands by soldering.
(Either of two places.)
Connector
View for A
Fig. D3
1-5-3E61S0DC
3. How to Eject Manually
< Method 1 >
1. Remove the Bottom Cover.
2. Turn the unit over.
3. Insert the shaft less than a diameter of 3 mm (e.g. screwdriver) straightly into the opening as shown.
4. Turn the shaft along with the opening clockwise.
5. Repeat steps 3 and 4 until the tray will open.
6. Pull the tray slowly with a hand.
View for B
Rear
Turn the shaft along with
the opening clockwise.
Shaft
(e.g. screwdriver)
Opening
B
Front
Fig. D5
1-5-4E61S0DC
When a disc cannot be ejected by method 1, follow the procedure below and remove the Chassis Cover.
< Method 2 >
1. Remove the Top Cover, the Front Assembly, the
Reinforce Plate and the Front Bracket.
2. To remove the Chassis Cover, remove 4 Screws A
as shown in Fig. D6.
3. Remove a disc.
Screws A
Screws A
Chassis
Cover
Disc
Fig. D6
Reassembly note of the Chassis Cover:
1. Insert the pin A on the Chassis Cover into the hole
A on the Main Chassis as shown in Fig. D7.
Chassis Cover
Pin A
Hole A
Main Chassis
2. Tighten 4 Screws A as shown in Fig. D6.
Fig. D7
1-5-5E61S0DC
HOW TO INITIALIZE THE DVD PLAYER
To put the program back at the factory-default,
initialize the DVD player as the following procedure.
1. Press [1], [2], [3], [4], and [DISPLAY] buttons on
the remote control unit in that order.
Fig. a appears on the screen.
"
" differ depending on the models.
*******
MODEL : *******
Version
Region
: *.**
: *
EXIT: POWEREEPROM CLEAR : CLEAR
Fig. a
"
" differ depending on the models.
*******
2. Press [CLEAR] button on the remote control unit.
Fig. b appears on the screen.
MODEL : *******
Version
Region
: *.**
: *
EXIT: POWEREEPROM CLEAR : CLEAR
EEPROM CLEAR : OK
Fig. b
When “OK” appears on the screen, the factory
default will be set. Then the firmware renewal
mode is complete.
3. To exit this mode, press [POWER] button.
1-6-1E61S0INT
FIRMWARE RENEWAL MODE
1. Turn the power on and remove the disc.
2. To put the DVD player into version up mode, press
[9], [8], [7], [6], and [SEARCH MODE] buttons on
the remote control unit in that order.
Fig. a appears on the screen.
"
" differ depending on the models.
*******
F/W Version Up ModeModel No : *******
Please insert a DISC
for F/W Version Up.
VERSION : *.**
EXIT: POWER
Fig. a Version Up Mode Screen
3. Insert the disc for version up.
4. The DVD player enters the F/W version up mode
automatically. Fig. c appears on the screen. If you
enter the F/W for different models, “Disc Error” will
appear on the screen, then the disc will be ejected
automatically.
"
" differ depending on the models.
*******
(*1)
F/W Version Up ModeModel No : *******
VERSION : ************.ab6
Reading...
VERSION : *.**
5. After programming is finished, the disc will be
ejected automatically. Fig. e appears on the
screen and the checksum will be shown in (*2) of
Fig. e.
"
" differ depending on the models.
*******
(*2)
F/W Version Up Mode
VERSION : ************.ab6
Completed
SUM : 7ABC
Model No : *******
VERSION : *.**
Fig. e Completed Program Mode Screen
At this time, no button is available.
6. Remove the disc.
7. Unplug the AC cord from the AC outlet. Then plug
it again.
8. Turn the power on by pressing the [POWER]
button.
9. Press [1], [2], [3], [4], and [DISPLAY] buttons on
the remote control unit in that order.
Fig. g appears on the screen.
"
" differ depending on the models.
*******
MODEL : *******
Version
Region
: *.**
: *
Fig. c Programming Mode Screen
The appearance shown in (*1) of Fig. c is
described as follows:
No.AppearanceState
1Reading...Sending files into the memory
2Erasing...Erasing previous version data
3Programming... Writing new version data
EXIT: POWEREEPROM CLEAR : CLEAR
Fig. g
10. Press [CLEAR] button on the remote control unit.
Fig. h appears on the screen.
"
" differ depending on the models.
*******
MODEL : *******
Version
Region
: *.**
: *
EXIT: POWEREEPROM CLEAR : CLEAR
EEPROM CLEAR : OK
Fig. h
When “OK” appears on the screen, the factory
default will be set. Then the firmware renewal
mode is complete.
11. To exit this mode, press [POWER] button.
1-7-1E61S0FW
BLOCK DIAGRAMS
System Control / Servo Block Diagram
IC101
(MICRO CONTROLLER)
ADAC-MD
AUDIO-MUTE
PCM-SCLK
57
88
163
56 ADAC-MC
86 ADAC-ML
IC462
+3.3V
RESET73
RESET
13
VREF
FOCUS DRIVE
FD-OFST
148
146
26
25
27
-
+
-
+
24
TRACKING
DRIVE
TD-OFST
147
139
-
+
-
+
POWER
SW2003
312
SW2002
OPEN/CLOSE
SPDL
76
-
+
-
+
STOP
-
SLD
75
23
CN1001
18
19 POWER
CN401
59POWER
IC202
PLAY
SW2001
19
OPEN/CLOSE
60OPEN/CLOSE
82
61
PLAY
STOP
SP-ROT
143
1
(OP AMP)
2
3
SENSOR
REMOTE
RM2001
23 REMOTE2222 PLAY2121 STOP2020
67
REMOTE
TRAY-IN
SL-ADS
140
675
66
LED-POWER
85
DISC-OUT
78
DISC-IN
81
SW2004
645
+
AV C BA
DVD MAIN CBA UNIT
Q801
RESET
IC461
21
(SERVO DRIVE)
+3.3V
*1
AUDIO-MUTE
ADAC-ML
ADAC-MC
ADAC-MD
PCM-SCLK
1 NOTE:
Either IC461 or IC462 is used for DVD MAIN CBA UNIT.
TO
VIDEO/ AUDIO
BLOCK DIAGRAM
IC301
FOCUS
ACTUATOR
15
FS(+)
FS(-)
DRIVE
16
TO DIGITAL SIGNAL
TRACKING
ACTUATOR
14
TS(+)
TS(-)
PROCESS BLOCK
DIAGRAM
DRIVE
13
1-8-1
SPINDLE
MOTOR
DRIVE
12
11
DRIVE CBA
SLED
17
TRAY-IN
MOTOR
DRIVE
18
CN301
SPINDLE
MOTOR
M
3SP(+)
4SP(-)
5TRAY-IN
6GND
SLED
MOTOR
7SL(-)
M
+3.3V
8SL(+)
Q804
CN801CN5001
1
LED-POWER
1
SENSOR CBA
Q802
3
2
3 DISC-IN
2 DISC-OUT
DISC-OUT
DISC-IN
E61S0BLS
Digital Signal Process Block Diagram
TO
VIDEO
/AUDIO
BLOCK
DIAGRAM
TO
VIDEO
/AUDIO
BLOCK
DIAGRAM
FLASH
ROM
DATA(AUDIO) SIGNAL
DATA(VIDEO/AUDIO) SIGNALVIDEO SIGNAL
DATA
RAM
INST.
DSP
DECODER
STREAM
SPDIF
PCM-BCK
PCM-DATA
PCM-LRCLK
177
170
171
169
AUDI O
I/F
ROM
DATA
RAM
INST.
ROM
SERIAL
GENERAL
I/O
I/O
PROCESSOR
CPU
I/F
UMAC
READ
TIMER
INTERRUPT
CONTROLLER
I/F
MEMORY
VIDEO-Y(I/P)
149
Y(I/P)
D/A
NTSC/PAL
VIDEO
WATCH DOG
TIMER
REMOTE
VIDEO-C
158
C
D/A
ENCODER
I/F
CONTROL
32BIT CPU
BCU
DATA
INST
DEBUG
RAM
RAM
IC103 (FLASH ROM)
~
~
1
9
162548
FADR (0-19)
23~51
~
293638
FDQ (0-15)
~
45
SDRAM ADDRESS(0-11)
IC101 (MICRO CONTROLLER)
~
217
238
SDRAM ADDRESS(0-11)
~~
222629
IC503 (SDRAM)
EXTERNAL
MEMORY
I/F
2
35
SDRAM
DECODER
I/F
ECC
SDRAM DATA(0-15)
~~
1
18
252
SDRAM DATA(0-15)
~
134253
192~212
CPU
I/F
DMA
RF
256
114
115
116
117
~
CN201
DVD/CD
FORMATTER
SIGNAL
PROCESS
132
131
C16
D18
CIRCUIT
134
133
A17
B15
DETECTOR
BCU
129
E14
130
F12
CD/DVD 19
32BIT
CPU
INST.
ROM
126
124
AMP
Q253,Q254
AMP
CN201
CD-LD 10
DVD-LD 8
DATA
RAM
125
123
Q251,Q252
6
5
PD-MONI 7
GND(CD-PD)
GND(DVD-PD)
9
GND(LD)
WATCH DOG
TIMER
TIMER
INTERRUPT
CONTROLLER
CD/DVD
83
TO SYSTEM
CONTROL/SERVO
BLOCK DIAGRAM
6
IC201
(SW)
4
1 3
CDDVD
FS
TS
FS(+)
CN201
FS(+) 2
FS(-)
FS(-) 3
TS(+)
TS(+) 1
TS(-)
DVD MAIN CBA UNIT
TS(-) 4
PICK-UP
UNIT
1-8-2
E61S0BLD
Video / Audio Block Diagram
VIDEO OUT
(COMPOSITE)
JK1402
AUDIO SIGNALDATA(AUDIO) SIGNAL
JK1401
S-VIDEO OUT
2
1
34
YC
DIGITAL
JK1202
AUDIO OUT
(COAXIAL)
(AMP)
IC1201
JK1201
1
3
AUDIO(L)-
OUT
2
AUDIO(R)-
675
OUT
Q1201
Q1202
VIDEO SIGNAL
WF3
5
2dB
AMP
2dB
LPFDRIVER
4dB
AMP
IC1403 (VIDEO DRIVER)
3
WF1
6
DRIVER
AMP
WF2
CN1601
7
DRIVER
2dB
AMP
LPF
4dB
AMP
1
+5V
D2010
POWER
AMP
Q1351
15
L-CH
LPF+AMP
DAC
ENHANCED
MULTI-LEVEL
WF4
WF6
CN601CN1601
14
R-CH
LPF+AMP
DAC
MODULATOR
DELTA-SIGMA
17
SPDIF
1312AUDIO(L)
18
WF5
14
AUDIO(R)
15
1413AUDIO(R)-MUTE
16
ZERO DETECT
+5V
CLOCK
SYSTEM
MANAGER
Q1204
5
+3.3V
87VIDEO-Y(I/P)
109VIDEO-C
CN601
VIDEO-Y(I/P)
VIDEO-C
TO DIGITAL
SIGNAL PROCESS
BLOCK DIAGRAM
1-8-3
IC601 (AUDIO DAC)
4X/8X
DIGITAL FILTER
OVERSAMPLING
AUDIO
7
PCM-BCK
SPDIF
PCM-DATA
TO
DIGITAL
SIGNAL
PROCESS
/FUNCTION
CONTROLLER
PORT
SERIAL
6
8
PCM-LRCLK
BLOCK
DIAGRAM
SERIAL
CONTROL
432
ADAC-MD
ADAC-MC
ADAC-ML
PORT
TO
SYSTEM
CONTROL
/SERVO
BLOCK
DIAGRAM
PCM-SCLK
AUDIO-MUTE
E61S0BLV
DVD MAIN CBA UNITAV CBA
Power Supply Block Diagram
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
EV+5V
P-ON+9V
EV+3.3V
P-ON+5V
EV+1.2V
TO CN401
1,2
EV+3.3V
3,4,5
EV+10V7P-ON+5V6P-ON+3.3V17PWRCON
8,9
"Ce symbole reprèsente un fusible à fusion rapide."
"This symbol means fast operating fuse."
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de même type.
Risk of fire-replace fuse as marked.
F
COLD
11
A V
T1001
2
HOT
2
+1.2V
IC1002
3
3
SCHOTTKY
D1006
12
1
REG.
BARRIER
D1008
SCHOTTKY
BARRIER
D1030
13
4
Q1002CN1001
RECTIFIER
14
15
Q1011
Q1004
Q1016
312
REG
IC1006
16
17
18
1
4
IC1001
ERROR
7
6
VOLTAGE DET
2
3
(SHUNT REGULATOR)
HOT CIRCUIT. BE CAREFUL.
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
BRIDGE
RECTIFIER
D1001, D1002
D1004, D1005
LINE
FILTER
L1001
F1001
1A 250V
AC1001
AC CORD
F
SWITCHING
SWITCHING
Q1003Q1031
A V
CONTROL
1-8-4
AV CBA
E61S0BLP
SCHEMATIC DIAGRAMS / CBA’S AND TEST POINTS
Standard Notes
WARNING
Many electrical and mechanical parts in this chassis
have special characteristics. These characteristics
often pass unnoticed and the protection afforded by
them cannot necessarily be obtained by using
replacement components rated for higher voltage,
wattage, etc. Replacement parts that have these
special safety characteristics are identified in this
manual and its supplements; electrical components
having such features are identified by the mark “#” in
the schematic diagram and the parts list. Before
replacing any of these components, read the parts list
in this manual carefully. The use of substitute
replacement parts that do not have the same safety
characteristics as specified in the parts list may create
shock, fire, or other hazards.
Notes:
1. Do not use the part number shown on these
drawings for ordering. The correct part number is
shown in the parts list, and may be slightly
different or amended since these drawings were
prepared.
2. All resistance values are indicated in ohms
(K = 10
3. Resistor wattages are 1/4W or 1/6W unless
otherwise specified.
4. All capacitance values are indicated in µF
(P = 10
5. All voltages are DC voltages unless otherwise
specified.
3
, M = 106).
-6
µF).
1-9-1E6N_SC
LIST OF CAUTION, NOTES, AND SYMBOLS USED IN THE SCHEMATIC DIAGRAMS ON
THE FOLLOWING PAGES:
1. CAUTION:
FOR CONTINUED PROTECTION AGAINST FIRE HAZARD, REPLACE ONLY WITH THE
F
A V
SAME TYPE FUSE.
ATTENTION: POUR UNE PROTECTION CONTINUE LES RISQES D'INCELE N'UTILISER
QUE DES FUSIBLE DE MÊME TYPE.
RISK OF FIRE-REPLACE FUSE AS MARKED.
This symbol means fast operating fuse.
Ce symbole represente un fusible a fusion rapide.
2. CAUTION:
Fixed Voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown, first check to see that all components in the power supply circuit are not
defective before you connect the AC plug to the AC power supply. Otherwise it may cause some components
in the power supply circuit to fail.
3. Note:
1. Do not use the part number shown on the drawings for ordering. The correct part number is shown in the
parts list, and may be slightly different or amended since the drawings were prepared.
2. To maintain original function and reliability of repaired units, use only original replacement parts which are
listed with their part numbers in the parts list section of the service manual.
4. Voltage indications for PLAY and STOP mode on the schematics are as shown below:
2
1
(Unit: Volt)
The same voltage for
both PLAY & STOP modes
5.0
3
5.0
(2.5)
Indicates that the voltage
is not consistent here.
PLAY mode
STOP mode
5. How to read converged lines
1-D3
Distinction Area
Line Number
(1 to 3 digits)
Examples:
1. "1-D3" means that line number "1" goes to the line number
"1" of the area "D3".
2. "1-B1" means that line number "1" goes to the line number
"1" of the area "B1".
3
AREA D3
2
1
ABCD
AREA B1
1-D3
1-B1
6. Test Point Information
: Indicates a test point with a jumper wire across a hole in the PCB.
: Used to indicate a test point with a component lead on foil side.
: Used to indicate a test point with no test pin.
: Used to indicate a test point with a test pin.
"Ce symbole reprèsente un fusible à fusion rapide."
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de même type.
Risk of fire-replace fuse as marked.
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
1-9-7
E61S0SCAV1
AV 2/2 Schematic Diagram
AV 2/2
Ref No.Position
IC1201H-1
IC1403I-4
Q1201J-1
Q1202J-1
Q1204I-1
Q1351J-4
Q1352H-2
CN1601G-3
ICS
TRANSISTORS
CONNECTOR
1-9-8
E61S0SCAV2
AV CBA Top View
"Ce symbole reprèsente un fusible à fusion rapide."
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de même type.
Risk of fire-replace fuse as marked.
"This symbol means fast operating fuse."
A V
F
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
1-9-9
BE6160F01014
"Ce symbole reprèsente un fusible à fusion rapide."
CAUTION !
For continued protection against fire hazard,
replace only with the same type fuse.
ATTENTION : Pour une protection continue les risqes
d'Incele n'utiliser que des fusible de même type.
Risk of fire-replace fuse as marked.
"This symbol means fast operating fuse."
A V
F
AV CBA Bottom View
CAUTION !
Fixed voltage (or Auto voltage selectable) power supply circuit is used in this unit.
If Main Fuse (F1001) is blown , check to see that all components in the power supply
circuit are not defective before you connect the AC plug to the AC power supply.
Otherwise it may cause some components in the power supply circuit to fail.
WF3
C1402
PLUS LEAD
WF1
PIN 7 OF
CN1601
WF2
PIN 9 OF
CN1601
WF4
PIN 12 OF
CN1601
WF5
PIN 14 OF
CN1601
WF6
PIN 17 OF
CN1601
NOTE:
The voltage for parts in hot circuit is measured using
hot GND as a common terminal.
See Electrical Parts List
for parts with this mark.
Some Ref. Numbers are
not in sequence.
A-5
A-7
A-1
1B1
L2-1
L2-4
A-2
EWD70V5 only
L2-1
A-8
L2-2
F1001
JK1401
AV CBA
JK1402
JK1201
JK1202
A-4
A-6
DVL505 only
1-14-1E61S0CEX
Packing
X-2X-3X-4
X-5
X-7
X-6
X-1
X-8
S-2
S-2
S-2
Unit
A-7
S-4
S-1
1-14-2E61S0PEX
MECHANICAL PARTS LIST
PRODUCT SAFETY NOTE: Products marked with a
# have special characteristics important to safety.
Before replacing any of these components, read
carefully the product safety notice in this service
manual. Don't degrade the safety of the product
through improper servicing.
NOTE: Parts that are not assigned part numbers
(---------) are not available.
S-1AGIFT BOX E61S0UD1VM320700
S-1BGIFT BOX CARTON E61S1UD1VM320857
S-2SIDE PAD E61S0UD1VM120080C
S-4SET BAG E5960UD1VM420147
ACCESSORIES
X-1ASTAND E61S0UD1VM220356
X-1BSTAND E61S1UD1VM421737
X-2REMOTE CONTROL UNIT NB071UDNB071UD
X-3#AOWNERS MANUAL E61S0UD1VMN20420
X-3#BOWNERS MANUAL E61S1UD1VMN20692
X-4AV CORD TSCKA-Y/RW100WPZ0102TM015
X-5DRY BATTERY R6P/2SXB0M451T0001
X-6ACCESSORY BAG E5700UD0VM415576
X-7FOOT E61S0UD/1 SET 4 PCS1VM421328
X-8ACCESSORY BAG E5700UD0VM415576
----------
200503231-15-1E61S0CA
ELECTRICAL PARTS LIST
PRODUCT SAFETY NOTE: Products marked with a
# have special characteristics important to safety.
Before replacing any of these components, read
carefully the product safety notice in this service
manual. Don't degrade the safety of the product
through improper servicing.
NOTES:
1. Parts that are not assigned part numbers (---------)
are not available.
2. Tolerance of Capacitors and Resistors are noted
with the following symbols.
C.....±0.25%D.....±0.5%F.....±1%
G.....±2%J......±5%K.....±10%
M.....±20%N.....±30%Z.....+80/-20%
DVD MAIN CBA UNIT
Ref. No.DescriptionPart No.
DVD MAIN CBA UNITN7XF0JUP
AV CBA
Ref. No.DescriptionPart No.
AV C BA
Consists of the following:
CAPACITORS
C1001#METALLIZED FILM CAP. 0.047µF/250V MCT2E473MS037
C1003ELECTROLYTIC CAPACITOR
C1222ELECTROLYTIC CAP. 10µF/16V MCE1CMASDL100
C1240CERAMIC CAP.(AX) B K 1000pF/50VCCA1JKT0B102
C1245CHIP CERAMIC CAP.(1608) F Z 0.1µF/50VCHD1JZ30F104
C1246CHIP CERAMIC CAP.(1608) F Z 0.1µF/50VCHD1JZ30F104
C1247ELECTROLYTIC CAP. 470µF/6.3V MCE0KMASDL471
C1249ELECTROLYTIC CAP. 47µF/16V MCE1CMASDL470
C1351CHIP CERAMIC CAP.(1608) B K 0.1µF/25VCHD1EK30B104
C1352ELECTROLYTIC CAP. 47µF/6.3V M H7CE0KMASSL470
C1354CHIP CERAMIC CAP.(1608) CH J 100pF/50VCHD1JJ3CH101
C1361CHIP CERAMIC CAP.(1608) F Z 0.1µF/50VCHD1JZ30F104
C1394ELECTROLYTIC CAP. 47µF/10V MCE1AMASDL470
C1402ELECTROLYTIC CAP. 470µF/6.3V MCE0KMASDL471
C1403CHIP CERAMIC CAP.(1608) B K 0.33µF/10VCHD1AK30B334
C1422CHIP CERAMIC CAP.(1608) B K 0.1µF/25VCHD1EK30B104
C1423CHIP CERAMIC CAP.(1608) B K 0.01µF/50VCHD1JK30B103
C1443ELECTROLYTIC CAP. 1000µF/6.3V MCE0KMASDL102
C1524ELECTROLYTIC CAP. 100µF/6.3V MCE0KMASDL101
C1535CHIP CERAMIC CAP.(1608) B K 0.01µF/50VCHD1JK30B103
C1536ELECTROLYTIC CAP. 22µF/6.3V M H7CE0KMASSL220
C1537CHIP CERAMIC CAP.(1608) F Z 0.1µF/50VCHD1JZ30F104
C2031ELECTROLYTIC CAP. 100µF/6.3V MCE0KMASDL101
C2032CHIP CERAMIC CAP.(1608) F Z 0.1µF/50VCHD1JZ30F104
C2034CHIP CERAMIC CAP.(1608) CH J 1000pF/50VCHD1JJ3CH102
CONNECTORS
CN100122P FFC AV PCB TO MAINWX1E5900-001
CN160111P FFC AV PCB TO MAIN PCBWX1E61S0-002