Sylvania DULUX CF42, DULUX 20851, DULUX 20566, DULUX 20866 User Manual

Product Information Bulletin
DULUX®DT/E/C
4-Pin Amalgam Compact Fluorescent Lamps
SYLVANIA DULUX DT/E/C industry exclusive amalgam compact fluorescent lamp is ideal for use in a wide range of high temperature applications.
• Improved high temperature performance – Maintains 90% lumens from 60°F to 175°F
• Latest generation higher temperature rated composite (metal/plastic) base cap
• Designed to exceed IEC safety requirements*
• Extended range of color temperatures: 3500K, 4100K and 5000K with impr
oved
color consistency
• Operates on various ballast systems – Flicker free start on electronic ballasts – Compatible with QUICKTRONIC
®
System CF
• Less power consumption than incandescent of comparable light output
• High luminous efficacy
• Long 12,000 hour average rated life – Reduces relamping requirement and
related cost
• Rare earth tri-phosphor with 82 CRI
* Regulations may vary. Check your local and state regulations.
DULUX DT/E/C amalgam lamps are ideal for enclosed, exterior and small fixtures. The lamps have improved amalgam technology and higher temperature rated components. This lamp has the next generation composite (metal/plastic) base cap which has been designed to exceed IEC safety requirements.
Product Availability
Lamp Wattage Rated Lumens
CF42 DT/E/C 42 3200
System Comparison
Compact Fluorescent vs Incandescent
Lamp Type Lamp Life Lumens Wattage LPW Savings
150W Incandescent 750 hrs. 2740 150W 18.5 – DULUX DT/E/C
1. Based on $.10/kWh over 12,000 hours.
Application Infor
Applications
Recessed ceiling fixtur Industrial lighting Showcase lighting
all sconces
W
ask lighting
T Exit signs
den and walkway lighting
Gar
es
Fixtur
Contact your local fixtur
Ballast Information
Contact your OSRAM SYL of compatible operating systems.
mation
es, enclosed exterior fixtures
e agent for available fixtur
esentative for a list
epr
ANIA r
V
Rated System System System Energy
12,000 hrs.
es.
3200
Application Notes
1. 4-Pin lamps designed for electronic ballast operation. ecommended for dimming.
Not r Recommended for use with ballasts that operate the lamp
2.
in compliance with ANSI/IEC specifications.
3. Minimum starting temperature depends on ballast.
4. Rule of thumb: to estimate the appropriate compact fluorescent
lamp wattage, divide the incandescent wattage by 4.
5. Equipment manufacturers are advised to consult ANSI and
IEC standards for the maximum allowable dimensions and temperatur
46W
e to ensur
e compatibility with similar pr
70 $124.00
oducts.
1
CF045R1 3/08
0
10
20
30
40
50
60
70
80
90
100
110
5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95
41 50 59 68 77 86 95 104 113 122 131 140 149 158 167 176 185 194 203
AMBIENT TEMP. (Deg. C & Deg. F)
RELATIVE LIGHT OUTPUT (%)
DULUX DT/E/C
DULUX T/E/IN
Sample Specification
B
D
A
C
100
90
80
70
60
50
40
30
20
10
0
0 20 40 60 80 100 120 140 160 180 200
PERCENT RATED LIFE
PERCENT SURVIVING
Lamp(s) shall be (a) DULUX
®
(DT/E/C) lamp(s) that pass existing Federal TCLP limits. Lamp(s) shall have an average rated life of 12,000 hours, a cor
related color temperature of (3500K, 4100K or 5000K), and a CRI of 82. Lamps shall have a (GZ24q-4) plug-in, 4-pin base and be suitable for use on elec­tronic ballasts. Lamps shall be operated by QUICKTRONIC ballasts. Both lamps and ballasts are covered by the QUICK 60+
®
system war
ranty.
Warranty Information
QUICK 60+ warranty for OSRAM SYLVANIA lamp and ballast combination
Limited 6 month lamp warranty and a five year ballast warranty is possible if both lamps and ballasts ar
e provided by OSRAM SYLVANIA. See the QUICK 60+ warranty for details and restrictions.
Ordering and Specification Information
Item Ordering NEMA Generic Initial Mean Color Av. Rated Number Abbreviation Designation Base Watts Volts1Amps1Lumens Lumens2Temp. CRI Life(hrs.)
20566 CF42 DT/E/C/835 CFM42W/GZ24q/35 GZ24q-4* 42 135 0.320 3200 2752 3500K 82 12,000 20851 CF42 DT/E/C/841 CFM42W/GZ24q/41 GZ24q-4* 42 135 0.320 3200 2752 4100K 82 12,000 20866 CF42 DT/E/C/850 CFM42W/GZ24q/50 GZ24q-4* 42 135 0.320 3200 2752 5000K 82 12,000
*Base compatible with new proposed high temperature socket and with GX24q-4 socket.
1. @ 25 KHz
2. Measur
3. Based on 3 hours per star
Contact your SYLVANIA sales representative for product availability.
ed at 40% (4800 hours) of rated life.
t. Number of operating hours when half have failed and half are still operating.
Ordering Guide
CF 42 DT / E / C / 835
Compact Wattage DULUX For electronic Constant 82 CRI
Fluorescent Triple ballasts luminous 35 = 3500K
flux 41 = 4100K
50 = 5000K
Dimensions
(A) (B) (C) (D)
MOL Max. Base Face to
[in. (mm)] Top of Lamp [in. (mm)] [in. (mm)] [in. (mm)]
CF42DT/E/C 6.42 (163) 5.79 (147) 1.90 (49) 0.62 (16)
Max. Base Width Guide Post
3
ANIA
OSRAM SYL National Customer Service and Sales Center
V
18725 N. Union Street Westfield, IN 46074
Industrial Commercial
Phone: 1-800-255-5042 Fax: 1-800-255-5043
National Accounts
Phone: 1-800-562-4671 Fax: 1-800-562-4674
OEM/Special Markets
Phone: 1-800-762-7191 Fax: 1-800-762-7192
Display/Optic
1-888-677-2627
Phone: Fax: 1-800-762-7192
In Canada OSRAM SYLVANIA LTD. 2001 Drew Road Mississauga, ON L5S 1S4
Industrial Commercial
1-800-263-2852
Phone: Fax: 1-800-667-6772
Special Markets
Phone: 1-800-265-2852
1-800-667-6772
Fax:
Visit our website: www.sylvania.com
Technical Information
Relative Light Output vs Ambient Temperature*
* Graph measured in base-up orientation and at rated lamp current
escent Lamp Mor
ANIA and QUICK 60+ ar
V
SYL
ypical Fluor
T
egistered trademarks of OSRAM SYLVANIA Inc.
e r
DULUX and QUICKTRONIC are registered trademarks of OSRAM GmbH, used under license.
tality
© 2009 OSRAM SYLVANIA 3/08 Photography
Loading...