Sygonix HT100 User guide

User manual
SYGONIX
radiator thermostat HT100 Art.-No. 1377979
RAV Pin
Attention
• For safety and licensing (CE) reasons, unauthorized conversion and/or
• The product is not a toy, it does not belong in children‘s hands.
• The product is only suitable for indoor use, it must not get damp or wet.
• Do not carelessly leave packaging material lying around.
• It could be a dangerous toy for children.
• Be careful when using the product. Knocks, blows or even a
• Should you have any questions that are not answered in this manual,
0-6
AKKU
AKKU
• Keep batteries out of the reach of children. Do not let batteries lying
• Leaking or damaged batteries can cause burns on contact with skin,
• Batteries must not be shorted, disassemble or thrown into the fire.
• Conventional non-rechargeable batteries cannot be recharged,
• Do not mix batteries with different state (e.g., full and half-full
• When inserting the batteries pay attention to the correct polarity
Controls
Vacation Function
modification of the product is prohibited. NEVER disassemble it.
fall from a low height can damage it.
please contact us or another professional.
around openly as there is the danger of them being swallowed by child­ren or pets. If swallowed, consult a doctor immediately!
therefore use suitable protective gloves when handling t hem. Leaking battery fluids are chemically very aggressive. Objects or surfaces which come into contact with them, can sometimes be massively damaged. Keep batteries at a suitable location.
Risk of explosion!
Risk of explosion!
batteries. Always replace the whole set of batteries.
(Note: Plus / + and minus).
Heating Time
Bold for
RAVRA RAVL
Adapter
Mounting
1. Remove battery cover/Insert batteries
Pull the battery cover, in the recess on the underside of the housing, upwards. Insert two batteries of type AA/Mignon with correct polarity (observe plus / + and minus / -, see imprint in the battery compartment). Pay attention to the correct position of the batteries to avoid contact interference. Close the battery compartment again. Due to the lower output voltage of batteries (batteries = 1.5V, rechargeable batteries = 1.2V) there may be a very short period of operation. We therefore recommend to use high quality alkaline batteries for a long and safe operation.
2. Enter Date and Time
yyyy
dd:mm
hh:mm
OKOKOK
Economy Temp erature
Open Window
Function
MANU/AUTO
Menu structure overview
WHEEL
MENU
MODE
PROG
TEMP
ZEIT
FENS
RES
ADAP
URLA
INST
OFFS
VERS
MODE
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
OK
02461218
Mo Di Mi Do Fr Sa So
AUTO MANU
MENU OK
Modus
PROG TEMP ZEIT FENS RES
AUTO/MA NU
DAY 1
Comf ort temp eratur AUS /EIN
year
Actuator travel adjustment
Temper ature flu ctuatio n -/+5C°
month day hours minute
OK OK
sensibility
Reset f actor y setti ngs
Holid ay period Pr ofile
Mounting position
Software version
:
keylock
Batterieverbrauch
MENU
But ton: Main Menu
OK
Button: Confirmation
But ton: Time r functi on
ADAPURLA INST OF FS VERS
OK OK
Set- back temp erature AU S/EIN
OK
OK OK
OK
time (minutes)
3.a Mounting on the radiator without adapter Valve - Radiator Thermostat HT100
1. 2.
INSTPREP
3.b Mounting on the radiator with adapter Valve – Adapter – Radiator Thermostat HT100
1. 2.
No ada pter is req uire d for the foll owing valves:
Heim eier, Junker s Landys+G yr, MNG, H oneywell Braukmann, since thes e have threa d dimensio ns of M30 x 1.5 mm. A dapter s for Danfo ss RAV (pin must be put on the va lve tap pet) Danf oss RA and D anfoss R AVL are encl osed.
An ada pter is req uired for the following val ves:
Herz M 28 x 1,5 mm, Comap M28 x 1, 5 mm, Vai llant 30,5 mm, Oven trop M30 x 1,0 mm , Meges M38 x 1,5 mm, Ondal M38 x 1,5 mm , Giacomin i 22,6 mm, Ross weiner M33 x 2,0 mm, Ma rkaryd M28 x 1,0 mm , Ista M32 x 1,0 m m, Vama M28 x 1,0 mm , Pettina roli M28 x 1,5 mm, T+A M28 x 1, 5 mm ode r Gamppe r 1,2,6.
4. Adapt
OK
ADAP
Start ready.
Basic Operating Modes MANU mode: In the MANU Mode HT100 regulates to the set temperature by hand. AUTO Mode: HT100 changes in the AUTO Mode according to the set
Time program between two temperatures. The heating and economy times can be specified via the adjustable time program. A maximum of 8 switch points (4 heating and 4 economy times) may be set per day. The Radiator Thermostat HT100 has the following factory settings: Heating time: Heating to comfort temperature (factory setting: 1. heating time at 07:00 clock - 21 ° C) Saving time: Reduction to economy temperature (factory setting: 1. saving time at 22:00 clock - 16 ° C) With the setting wheel a change in the room temperature is possible in the AUTO Mode at any time, this will remain until the next switching point. The process can be terminated prematurely by pressing the MENU button.
If E1appears in t he display then t he insta llation wa s
E1
not succes sful. Lo ok at the Sup port Table.
3.
INSTPREP
www.sygonix.com
Setting Individual Program
MENU
Set the beginning of the 1. Heating Time
You can optionally enter additional heating and economy periods. If you do not want to make any further settings, confirm the display „–– ––“with OK.
PROG
LED
The LED lights up in each case during the heating-phase until the set temperature is reached.
OK
DAY1
Monday
OK
Set the beginning of the 1. Economy Time
keylock
OK
Hold both buttons
+
for several seconds. Activate key lock. To deactivate, hold the two buttons pressed for several seconds.
Day/
Block
D1-5 Mo-Fr D1-6 Mo-Sa D1-7 Mo-Su
OK
Setting Holidays
Hilfe
Problem Cause Solution
OK
Radiator i s not getting warm.
Radiator i s not cooling down.
Thrust piece falls out. (This may also cause an E1 error!)
E1-E3
E1
E2
E3
Batteries are low Change batteries
Boil er wat er temper ature O.K.?
Valve does not open, af ter Summ er heating p ause­calcified?
Valve does not close completely. Possibly the closing point of your your valve seat has moved.
Due to a n endless t hread the th rust piece mou nted o n the botto m may fall ou t when the co ntroller was not a pplied on the v alve.
By pressing any button the fault indicator disappears from the display and the adaptation restarts!
No adaptation possible.
Radiator Thermostat HT100 not mounted on radiators.
Valve lift too short or Battery power too weak.
No valve movement possible. Do valve tappets move freely?
Correct water temperature of the boiler Take off Radiator Thermostat HT100 Move by hand the valve tappets back and forth several times.
EAdapt again (see “Adaptation”) Repeatedly move valve tappets by hand - perhaps an adaptation is not possible because your valve may be calcified, or the seal does no longer fulfill its function.
Inse rt thrus t piece. Ad apt t he device via t he removing a nd re-inser ting the batteri es. No w, the endless thr eat rota tes a nd tighte ns the thru st piec e fir mly. Atta ch to the radiator and adapt a gain.
s the device correctly mounted on the radiator?
Mount Radiator Thermostat HT100.
Open and close valve tappets by hand several times or install new batteries.
MEN
point, or by
First set t he date of the re-start of t he
OK
MENU URLA
Select temperature
OK
regular heating time. (Set the end of the holiday)
The process can be terminated prematurely by pressing the MENU button.
Setting Offset
Room temperature adjustment. Here you have the possibility to set a temperature of (-5 / + 5 °). The temperature determined
MENU OFFS
OK
by the instrument may differ from the perceived temperature by the user. In this case, the temperature determined by the instrument must be adjusted.
Timer function
Here any temperature for a selected time period can be set. Press button, set the time for which the timer program is to be overridden. Confirm with OK. Set the desired temperature. Confirm with OK. A manual temperature change is then in the given period not possible, the setting wheel is locked. By pressing the Menu button, the lock-up can be released.
Dismantling
1. 2.
Declaration of Conformity
OK
Hereby, Con rad Electron ic SE, K laus-Conr ad-Stra ße 1, D-922 40 Hir schau declares , that this produ ct is in compliance wi th the essential req uire ment s and ot her releva nt provisi ons of Directi ve 1999/5/ EC. The De claratio n of
Conf ormity f or this pro duc t can be f ound at www.conrad.com
Advice on environmental protection:
From the date of implementati on of European guidelines 2002/96/EC and 2006/66/EC, into national law, the following applies: Electric and electronic devices and batteries may not be disposed of in household waste. The consumer
OK
is obliged to return electric and electronic devices and batteries to the public
collection points established for them or to the point of sale. The particulars of this are regulated by the applicable state laws. The symbol on the product, operation instructions or packaging points to these provisions. You make an important contribution to the protection of the environment by reusing or recycling old equipment/batteries or making use of them in other ways.
Guarantee
For damages caused by failure to observe this Instruction Manual, the warranty/guarantee is voided! For consequential damages we assume no liability! For material or personal dam­age caused by improper handling or failure to observe the safety information, we assume no liability! In such cases, the warranty/guarantee is voided!
Maintenance and Cleaning
Maintenance or repair may only be performed by a specialist or specialist workshop. There are no serviceable components for you inside the product, therefore, never open/disassemble it (except for the battery change as described in this manual). Never use aggressive cleaning agents, rubbing alcohol or other chemical solutions as they may cause damage to the housing or even impair its operational functions.
In ord er to disassemb le the Radiator T hermos tat HT100 set t o positio n ON, for this t urn the set ting whee l beyond the hig hest tem peratur e of 28 C° until O N appear s in the disp lay. Wait brie fly before loo sening th e screw con nectio n. Then pul l off the Radiator Th ermost at HT100 from the va lve.
Technical Specifications
Power supply: 2 AA batteries / Mignon Factory settings: Comfort temperature: 21 ° C Economy temperature: 16 ° C
1. Heating time: Start 7:00 o’clock
1. Economy Time: Start 22:00 o’clock Switching points: 4 heating times, 4 economy times Frost protection function: Yes, activation at temperature below +6 ° C Calcification protection: Yes, valve movement 1x per week Window function: Yes Modes: Automatic / Manual Dimensions: 80 x 70 x 52 mm (W x H x D)
sygonix®
distributed by Conrad Electronic SE Klaus-Conrad-Str. 1 D-92240 Hirschau
www.sygonix.com
Loading...