1.0 Introduction1.0 Introduction
Sycard Technology's PCCextend 145 HP Logic Analyzer Adapter is an accessory product for the PCCextend 140 CardBus extender card. The PCCextend 145 is designed to interface with HP logic analyzers that use the 015650­63203 termination adapter.
For use with Sycard’s PCCextend 140 CardBus extender Card
Supports all HP logic analyzers that use the HP 01650-63203 Termination Adapter
Multi-layer construction to insure a low noise environment
Connects to all CardBus signals
Supports both timing and state analysis
Unused logic analyzer inputs accessible via test points.
Plug-in design allows for easy attachment and removal
2.0 Using the PCCextend 1452.0 Using the PCCextend 145
The PCCextend 145 is installed onto the two 34 pin headers located on the PCCextend 140 CardBus extender. The adapter should be mounted in the orientation shown in figure 2.0-1. Once installed, the HP termination adapters (on pods 1-4) can be installed on connectors JP1 through JP4.
Towards Card
JP1
JP2
JP3
JP4
Figure 2.0-1 The PCCextend 140Figure 2.0-1 The PCCextend 140
JP5
JP6
ABC
E
D F
M200014-00 1994-96 Sycard Technology
Page 4
Page 2 PCCextend 145 User’s Manual
The following tables list the mapping of signals to the HP Logic analyzer adapter:
AnalyzerAnalyzer InputInput
CardBusCardBus SignalSignal
CardBusCardBus
SignalSignal
NoteNote
PinPin
Pod 1-0 CCBE0# 7 Pod 1-1 CCBE1# 12 Pod 1-2 CCBE2# 21 Pod 1-3 CCBE3# 61 Pod 1-4 CREQ# 60 Pod 1-5 CGNT# 15 Pod 1-6 CFRAME# 54 Tie JP5-2 to JP5-3 Pod 1-7 CDEVSL# 50 Pod 1-8 CIRDY# 20 Tie JP6-2 to JP6-3 Pod 1-9 CTRDY# 53 Tie JP3-2 to JP3-3 Pod 1-10 CPAR 13 Pod 1-11 CSTOP# 49 Pod 1-12 CBLOCK# 48 Pod 1-13 CPERR# 14 Pod 1-14 CSERR# 59 Pod 1-15 CCLK 19 Tie JP4-2 to JP4-3 Pod 2-0 CAD0 2 Pod 2-1 CAD1 3 Pod 2-2 CAD2 37 Pod 2-3 CAD3 4 Pod 2-4 CAD4 38 Pod 2-5 CAD5 5 Pod 2-6 CAD6 39 Pod 2-7 CAD7 6 Pod 2-8 CAD8 41 Pod 2-9 CAD9 8 Pod 2-10 CAD10 42 Pod 2-11 CAD11 9 Pod 2-12 CAD12 10 Pod 2-13 CAD13 44 Pod 2-14 CAD14 11 Pod 2-15 CAD15 45
Table 2.1-1A Signal Connection Table - Part ATable 2.1-1A Signal Connection Table - Part A
1994-96 Sycard Technology M200014-00
Page 5
PCCextend 145 User’s Manual Page 3
AnalyzerAnalyzer InputInput
CardBusCardBus SignalSignal
CardBusCardBus
SignalSignal
NoteNote
PinPin
Pod 3-0 CAD16 46 Pod 3-1 CAD17 55 Pod 3-2 CAD18 22 Pod 3-3 CAD19 56 Pod 3-4 CAD20 23 Pod 3-5 CAD21 24 Pod 3-6 CAD22 25 Pod 3-7 CAD23 26 Pod 3-8 CAD24 27 Pod 3-9 CAD25 28 Pod 3-10 CAD26 29 Pod 3-11 CAD27 30 Pod 3-12 CAD28 64 Pod 3-13 CAD29 31 Pod 3-14 CAD30 65 Pod 3-15 CAD31 66 Pod 4-0 CCLKRN# 33 Pod 4-1 CINT# 16 Pod 4-2 CAUDIO 62 Pod 4-3 CRST# 58 Pod 4-4 RFU1 32 Pod 4-5 RFU2 40 Pod 4-6 RFU3 47 Pod 4-7 CSTSCHG 63 Pod 4-8 CVS1 43 Pod 4-9 CVS2 57 Pod 4-10 JP1-1 (A) - General Purpose Input Pod 4-11 JP2-3 (F) - General Purpose Input Pod 4-12 JP1-2 (C) - General Purpose Input Pod 4-13 JP2-2 (D) - General Purpose Input Pod 4-14 JP1-3 (E) - General Purpose Input Pod 4-15 JP2-3 (F) - General Purpose Input
Table 2.1-1B Signal Connection Table - Part ATable 2.1-1B Signal Connection Table - Part A
The PCCextend 145 was designed to be used as state or timing analyzer. Jumpers JP3 through JP4 route selected signals to either regular input channels or CLK inputs.
M200014-00 1994-96 Sycard Technology
Page 6
Page 4 PCCextend 145 User’s Manual
JP3JP3 CTRDY# JumperCTRDY# Jumper
1 - 2 CTRDY# is CLK1 on POD 4 2 - 3 CTRDY# in D9 input on POD 1
JP4JP4 CCLK JumperCCLK Jumper
1 - 2 CCLK is CLK1 on POD 1 2 - 3 CCLK is D15 input on POD 1
JP5JP5 CFRAME# JumperCFRAME# Jumper
1 - 2 CFRAME# is CLK1 on POD 3 2 - 3 CFRAME# is D6 input on POD 1
JP6JP6 CIRDY# JumperCIRDY# Jumper
1 - 2 CIRDY# is CLK1 on POD 2 2 - 2 CIRDY# is D8 input on POD 1
Table 2.1-2 Timing/State Clock Select JumpersTable 2.1-2 Timing/State Clock Select Jumpers
1994-96 Sycard Technology M200014-00
Page 7
PCCextend 145 User’s Manual Page 5
AppendixAppendix
A. PCCextend 145 SchematicA. PCCextend 145 Schematic
M200014-00 1994-96 Sycard Technology