SWS SPEEDCUT 50 Quick Reference Manual

Page 1
SPEEDCUT
50
1 Phase 240V +/- 15%
MIN GENERATOR
(8.5kVA at 0.8 PF)
MIN 100 L/m - 75 psi
ERROR
FOR CONSUMABLES & SUPPORT GO TO WWW.SWSWELDING.COM.AU
ERROR! Under Pressure
ERROR! Missing Shield Cup
ERROR! Missing Electrode or Nozzle
ERROR! Over Temperature
QUICK REFERENCE GUIDE
CONTROL DIAL FUNCTIONS
NEGATIVE CENTRAL TORCH LEAD PORT
AIR INLET FITTING (ON BACK OF MACHINE)
ON/OFF SWITCH (ON BACK OF MACHINE)
POSITIVE GROUND CLAMP CABLE PORT
OPERATORS MANUAL
When illuminated refer to error code on display and resolve.
Amperage control/Press for 2 seconds for air test press to stop.
Read operators manual before use - download from swswelding.com.au
Air pressure is below 60 PSI.
Shield cup is damaged or missing; torch lead is not connected securely (Inspect & replace or install).
Electrode or nozzle is excessively worn or missing (Inspect & replace or install).
Machine has reached duty cycle limit allow to cool.
CAUTION! Only use clean, dry air for optimum cutting performance and to prevent premature servicing of internal regulator filter.
CAUTION! Ensure compressor/gas regulator pressure is set between 75 - 100 PSI. Exceeding 100 PSI can damage the internal regulator.
Move to dierent mains power outlet, eliminate or reduce extension lead, use higher output generator, reduce cutting amperage.
i
i
POWER
When illuminated the power source is on.
i
O.T
When illuminated machine is over temperature, do not turn o and allow to perform cooling cycle.
i
i
DIGITAL DISPLAY
Amperage setting , real time amperage display, error codes.
i
i
i
i
i
i
ERROR! Over Voltage
Incorrect input voltage supplied damage may have been caused. Contact support if persists.
50
CAUTION! If the mains power supply/generator is not suicient, the machine will not maintain a cutting arc, and it may damage the power source.
Page 2
Always turn the machine on and let it perform booting up cycle before connecting pressurised air line.
1
2
3
4
Secure quick connect fitting to the airline using supplied hose clamp and connect to male inlet fitting (Located on the back of the machine).
Connect the plasma torch lead to the torch socket and secure using the retaining nut. (Ensure to tighten)
Connect the ground cable connector to the positive terminal and turn clockwise to lock in place.
Plug machine into a suitable mains power supply or generator and turn on using the ON/OFF switch (Located on the back of the machine).
1
2
3
4
Protect your eyes and body. Always use an approved welding helmet/googles and filter lens shade #5 and wear protective clothing.
Push safety switch away with finger and pull trigger.
System will adjust air pressure then start pilot arc aer 2 seconds.
Release trigger to stop arc aer cut and to start the air cooling cycle (15 seconds).
Pull then release trigger to stop cooling cycle prematurely.
Always let machine perform cooling cycle aer long cuts as you may damage the torch cartridge.
Place stando guide, drag tip, or position torch tip 3-9mm o the
metal at 90 degrees and pull the trigger. Once the cutting starts
begin to slowly move across the workpiece
i
WARNING! The pilot arc can cause serious burns - Never
engage trigger switch when torch tip is directed towards the eyes, face or body of yourself or others.
Adjust your speed so that sparks are coming from the backside of the
metal. If sparks are not visible at the bottom of the metal, you are not penetrating the metal. This can be caused by moving too fast, insuicient amperage or too thick of material for the rated capacity. At the end of the
cut angle, your torch past 90 degrees to completely sever the metal.
NOTE: Cut quality is highly dependent on setup and the cutting parameters such as alignment with the workpiece, torch stando, cutting speed, gas pressures, and operator ability.
FOR CONSUMABLES & SUPPORT GO TO WWW.SWSWELDING.COM.AU
START UP PROCEDURE
Loading...