SWIT EC-N200, EC-N200-4K, ET-N80 Users Guide

Page 1
Multi-Camera Production System
User Manual
Thank you for purchasing SWIT products!
Please read this manual carefully before using.
Ver:C
* NDI® is a registered trademark of Vizrt Group.
Page 2
Contents
Statement Safety Precautions Introduction Features Index of Parts and Functions The Camera Adaptor The Intercom Control Panel Get Started
1. System Connection
2. IP setup Webpage Settings - Camera Adaptor
1. Channel - Camera Channel configuration
2. Channel - Return Video Source Select
3. Channel - NDI Group Setting
4. Channel - External Sources
3 4 5 5 6 6 7 8 8 9 10 10 10 11 11
5. Channel - Advanced Settings
6. Network - Change IP address
7. User Admin - Log-in ID and Password Setting
8. Firmware Update Webpage Settings - Intercom Control Panel
1. Channel - Assign Camera Adaptors
2. NDI settings Indicators Troubleshooting Specifications Dimensions Packing List
12 12 13 13 14 14 14 15 16 17 18 18
2
Page 3
Statement
Any internal technology of this product (including hardware equipment, software design, and product trademark) is protected by law, and any violation of the intellectual property rights of this product will be investigated for legal responsibility.
All the company's brands and trademarks in this product are protected by law. All brands and trademarks of other companies involved in the product are legally protected by their owners.
In order to better serve the majority of users, the company's products will continue to improve and develop, and the company reserves the right to modify and improve the products described in this manual without prior notice.
The warranty period of this product is two years, and the following conditions are not covered by the warranty:
(1) Man-made damage such as appearance wear and tear; ⑵ Product failure or damage caused by failure to use, maintain and store according to the instructions; ⑶ When used in a special environment, the signal quality will be attenuated; ⑷ Product damage caused by using a non-product matching power adapter; ⑸ Other faults not caused by product design, technology, manufacturing, quality and other problems or unauthorized disassembly, repair or replacement parts etc.
If users find problems during use or have suggestions and requirements for our products, please contact us by telephone, fax, email, etc.
SWIT Electronics Co., Ltd.
Address: 10 Hengtong Road, Nanjing Economic and Technological Development Zone, Nanjing 210038, P.R. China Phone: +86-25-85805753 Fax: +86-25-85805296 Email: contact@swit.cc http//www.swit.cc
3
Page 4
Safety Precautions
Please follow the safety precautions in this manual and operate in the correct way. Our company guarantees that this product can be used for a long time, but the following situations are not included:
1.Unauthorized disassembly, maintenance or replacement of parts and other operations.
2.Damage caused by accident, including but not limited to lightning, fire, exposure to rain or moisture.
3.The type of power source being used is not within the voltage range allowed for this product.
Warning
Do not let any liquid splash on the product.
In order to avoid electric shock, please do not block or paste the ventilation holes on the product, do not remove the product cover, or put pins, iron wires, and foreign objects into the gaps in the ventilation holes.
To reduce the risk of electric shock or fire, do not place this product in rain or moisture.
Danger
Before connecting with any equipment, please turn off the power first, and then operate.
Power socket: To avoid short-circuit electric shock or fire, please confirm that the type of power socket used is within the voltage range of this product.
Power cord: Do not place any objects or heavy objects on the power cord to prevent the power cord from being pressed or strained.
Power load: Do not exceed the load on the wall socket, extension cord or other porous sockets to avoid fire or electric shock.
Lightning: To avoid lightning or long time without use of the product, please remove the plug/external battery.
x
User environment
Do not place this product in an unstable place, the product may be seriously damaged due to falling.
Do not place this product near equipment that is too hot, too cold or too humid, or that will cause a strong magnetic field.
4
Page 5
Introduction
The SWIT NDI EFP system consists of camera adaptors EC-N200 (up to HD) or EC-N200-4K (up to 4K) and an intercom control panel ET-N80 with all the essential accessories for one-stop setup.
The EC-N200 camera adaptor takes 3G-SDI input from cameras, encoded to an HD NDI stream over an IP network, and the EC-N200-4K camera adaptor takes 12G-SDI input, and encodes to 4K NDI. Both of the HD and 4K versions support NDI PGM source decoded and monitoring output via HDMI. You can use any on-camera monitors with HDMI input, to monitor local camera video and return PGM video in pic-in-pic mode. The control buttons on the adaptor are available for intercom volume adjustment and Push-to-talk with the director. There’s on-board TALLY light for cameramen and also extended TALLY light for the anchor. The camera adaptors support PoE power and V-mount battery power as well.
The ET-N80 intercom control panel can be assigned with up to 8 camera adaptors, and supports link connection for more channels or for external 3rd party intercom system by 4-wire connector. Directors can talk to every cameraman individually by pushing button numbers or announce everyone by the ANN button, instead of selecting intercom channels from webpages.
The NDI EFP system has respected all the operation habits of SDI/Fiber EFP system, and greatly simplified cable works by using NDI IP solution. You can use any ENG cameras to build up a pure NDI production system, and all the intercom, TALLY, return video are based on NDI, the high quality and low latency IP video solution with reasonable network bandwidth.
Features
Encode camera SDI to high bandwidth NDI, HD up to 150Mbps and 4K up to 250Mbps.
Decode PGM NDI in every camera adaptor and display local video and return video together.
Full duplex intercom between cameramen and director.
The director can select camera numbers to talk individually or press ANN to talk to everyone.
The cameraman can initiate the call to director.
Provide dual colors on-board TALLY light and external TALLY light set on the front of the camera.
The camera adaptor supports DC-IN power, V-mount battery power and PoE power.
The intercom control panel can be connected into 3rd party intercom system.
5
Page 6
Index of Parts and Functions
(10)
The Camera Adaptor
EC-N200 / EC-N200-4K
(1)
(2)
(3)
(4) (5) (6)
(7) (8)
(9)
(11)
(1) External TALLY output, 3.5mm jack
(13)
(14)
SDI LOOP
(15)
SDI IN
(12)
(16)
(17)
(18)
(10) On-board TALLY light (2) Power ON/OFF switcher (3) Volume Up * (4) Volume Down * *Press both to call director (5) NDI return video Indicator (6) NDI return video switcher, press in turn: Local video → Local/Return PIP→ Return Video
(7) SDI input lock indicator (8) Press the pin to reset (9) 5-pin XLR headset input
(11) V-mount battery plate (Gold mount option)
(12) D-tap power output from battery
(13) HDMI Monitor out for Local / Return video
(14) SDI loop output*
(15) SDI input*
*EC-N200 up to 3G; EC-N200-4K up to 12G
(16) DC 11-17V input, 5.5/2.1mm jack
(17) RJ45 network cable fixer install position
(18) Gigabit high bandwidth NDI interface *
*EC-N200 up to 1080p50/60, 150Mbps
EC-N200-4K up to 2160p50/60, 250Mbps
6
Page 7
Index of Parts and Functions
(1) (2) (3) (4)(5)(6) (7)(8)(9) (10) (11)(12)(13)
The Intercom Control Panel
ET-N80
(14) (15) (16) (17) (18)
(1) 3-pin XLR Microphone socket (2) Mic/Headset switching button Press down to switch from Headset to Mic (3) 5-pin XLR Headset socket (4) Speaker, output when switching to Mic (5) Volume Down (6) Volume Up (7) ANN: Announcement mode Press to talk to all camera channels (8) MIC OFF: Turn off the Microphone input (9) MUTE: Turn off the Headphone/Speaker output (10) 1-8: Camera Channels 1-8 Press the numbers to talk individually (11) 4-Wire: External intercom channel
(12) Power ON/OFF switcher (13) Press the pin to reset (14) AC 100-240V 50/60Hz input (15) AC ON/OFF switcher (16) DC 11-17V input, 4-pin XLR (17) External intercom connect, RJ45 4-Wire * * Pin definition:
Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8
Null Null
Audio OUT +
Audio IN +
Audio IN -
Audio OUT -
Null Null
Press to take over external intercom
(18) NDI network connect, RJ45
7
Page 8
Get Started
1. System Connection
Connect all the camera adaptors and the intercom control panel to the NDI network.
EC-N200/N200-4K
Headset
15mm Rod Rail Clamp
HDMI output Local / Return video
Camera SDI Input
NDI
PoE Power
CAM 1
PGM
External TALLY light
15mm Rod Rail Camera Base
Install between camera and tripod
More Camera Channels, NDI switcher, NDI monitor etc.
ET-N80
Network Switcher
NDI
Headset
4-wire
3rd Party Intercom System
8
Page 9
Get Started
2. IP Setup
The camera adaptor and intercom control panel has factory default IP address:
Device EC-N200/N200-4K ET-N80
You can find the default IP address on the product label
Default IP
192.168.1.15X
192.168.1.101
Set computer IP address to the same segment, and connect directly with the device or through network switcher, by straight through RJ45 cable.
Launch web browser on the computer, input 192.168.1.15X to enter configuration webpage of the camera adaptor, and input
192.168.1.101 to enter configuration webpage of the intercom control panel.
Input User ID and password to log-in configuration webpage
Item User ID Password
Default
admin admin
9
Page 10
Webpage Settings - Camera Adaptor
1. Channel - Camera Channel configuration
Status Info List
No special characters accepted
IP address of assigned Intercom Control Panel
No special characters accepted
Click to enter the webpage of Intercom panel.
2. Channel - Return Video Source Select
Rename and Apply
All NDI sources in current network Select one source as “Return video”
to output via HDMI to camera top monitor
10
Page 11
Webpage Settings - Camera Adaptor
3. Channel - NDI Group Setting
Add, Delete, or Modify the name of NDI Group
The current NDI Group will displayed below.
4. Channel - External Sources
Change and Apply
Add device IP address to find NDI sources from subnet.
The current external device IP address will displayed below.
Change and Apply
11
Page 12
Webpage Settings - Camera Adaptor
5. Channel - Advanced Settings
6. Network - Change IP address
Select from:
Switch on NDI Discovery Server
Add NDI Discovery Server IP address
Change and Apply
UDP (unicast) UDP (multicast) RUDP (unicast) TCP (single connection) TCP (multi-connection)
Mac address display
Change address
Change and Apply
12
Page 13
Webpage Settings - Camera Adaptor
7. User Admin - Log-in ID and Password Setting
Change Log-in User name
4 - 16 letters
Re-type password
Change and Apply
8. Firmware Update
Check Serial Number, Model and NDI SDK
Restart the device
Drag & drop the firmware file (.img) to this block Or click the area to browse firmware file and apply
Important:DO NOT cut off power during firmware update
The device will automatically restart after firmware update.
Reset the device
13
Page 14
Webpage Settings - Intercom Control Panel
1. Channel - Assign Camera Adaptors
Search IP address or device name to add Camera adaptors
2. NDI Settings
Assigned devices:
Drag the devices to move positions (not available for the offline devices)
Display color - The device is online Display grey - The device is offline
Change and Apply
Click to remove the device
Add, Delete, or Modify the name of NDI Group
Add device IP address to find NDI sources from subnet.
Add NDI Discovery Server IP address
Change and Apply
14
Page 15
Indicators
1. The Camera Adaptor EC-N200/N200-4K
Singal Indicator Status/Color Instruction
OFF/ON
SDI IN
NDI RETURN
On board TALLY
External TALLY
2. The Intercom Control Panel ET-N80
On
Off
Red
Green
Red
Green
Red
Green
Amber
Red
Green
Amber
Powered on
Device not get powered
No SDI input recognized
SDI input recognized
No return NDI source recognized
Return NDI source recognized
The camera channel is PGM
The camera channel is PVW
The camera channel is both PGM & PVW
The camera channel is PGM
The camera channel is PVW
The camera channel is both PGM & PVW
Singal Indicator Status/Color Instruction
POWER
INPUT
1 2 3 4 5 6 7 8
4-wire
ANN
MIC OFF
On
Off
Red
Green
Red
Green
Red flashing
Red
Green
Off
Green
Off
Green
Powered on
Device not get powered
3-pin Microphone actived
5-pin Headset actived
The camera channel connected
The camera channel intercom actived
The camera channel is calling
External intercom system is connected
External intercom channel is actived
Individual intercom mode
Announcement mode
Microphone is turned on
Microphone is turned off
MUTE
Off
Green
Earphone or Speaker is turned on
Earphone or Speaker is turned off
15
Page 16
Troubleshooting
Phenomenon Possibility Reasons Solutions
No NDI video from camera channels
No return video display
Intercom can’t be connected
Unable to launch web configue page
Unable to upgrade firmware
Camera adaptor not get powered
Camera SDI not connected
Camera SDI format not supported
Network blocked
Didn’t select return video source
Return video not switched on
Low volume or Mic OFF or Mute
Camera adaptor not assigned
Wrong IP address
Web browser need refresh
Firmware file error
The device is already latest firmware
Check power supply
Check camera SDI cable
Check camera SDI format
Check IP address of the camera adaptor
Camera adaptor-Channel-Return source
Press Return button on camera adaptor
Check the button status
Check the channel assign settings
Check IP address of the device
Press Ctrl+F5 to refresh web browser
Make sure the file name is correct
Check the firmware version
16
Page 17
Specification
Input
Output
Video
Formats
SDI
NDI
EC-N200Camera Adaptor
3G-SDI ×1
3G-SDI loop ×1
HDMI 1.3 out ×1
High bandwidth NDI ×1
1080P(60/59.94/50/30/23.98/29.97/25) 1080I(60/59.94/50) 720P(60/59.94/50)
1080P(60/59.94/50/30/29.97/25) 1080I(60/59.94/50) 720P(60/59.94/50)
EC-N200-4K
12G-SDI ×1
12G-SDI loop ×1
HDMI 1.3 out ×1
High bandwidth NDI ×1
2160P(60/50/30/23.98/29.97/25) 1080P(60/59.94/50/30/23.98/29.97/25) 1080I(60/59.94/50) 720P(60/59.94/50)
2160P(60/50/30/29.97/25) 1080P(60/59.94/50/30/29.97/25) 1080I(60/59.94/50) 720P(60/59.94/50)
DC Input
Power
Environment
Size
Weight
AC Input
DC Input
Power
HDMI
1080P(60/59.94/50/30/23.98/29.97/25) 1080I(60/59.94/50) 720P(60/59.94/50)
DC/ Battery 11~17V,1.5A, PoE 42~57V,0.5A
16W
0℃~+40℃
139.23×176×52.5mm
742g
ET-N80Intercom Control Panel
100~240V, 0.5A
11~17V,1.5A
16W
1080P(60/59.94/50/30/23.98/29.97/25) 1080I(60/59.94/50) 720P(60/59.94/50)
Environment
Size
Weight
0℃~+40℃
482.6×164.4×44.5mm, 1U rackmount
1.5kg
17
Page 18
Dimension
EC-N200/N200-4K
ET-N80
Unit:mm
Unit:mm
Packing List
EC-N200/N200-4K
Single ear headset (5-pin XLR)
15mm rail rods
Camera 15mm rail base
Adaptor 15mm rail clamp
External TALLY with cable and coldshoe
RJ45 cable fixer
D-tap to 5.5/2.1mm DC cable
Carrying Case
×1
×2
×1
×1
×1
×1
×1
×1
ET-N80
Single ear headset (5-pin XLR)
Swanneck Microphone (3-pin XLR)
AC power cable
×1
×1
×1
18
Page 19
Loading...