Parts list
Parts QTY PARTS QTY
MCW5000-PX™ assembly 1 Arctic Alumina Thermal compound 1
Tube inserts 4
This product is intended for expert users. Please consult with a qualified technician for installation. Improper installation may result in
damage to your components. Swiftech assumes no liability whatsoever, expressed or implied, for the use of these products, nor their
installation. The following instructions are subject to change without notice. Please visit our web site at www.swiftnets.com
1. Before you install the MCW5000-PX™ water-block:
a. Prepare two pieces of tubing of sufficient length to connect to
the rest of your circuit. The cuts must be square as shown in figure
1 or leaks may occur:
Tube removal tool 1
b. Install the provided plastic tube inserts at each end of the tubes,
as shown in figure 2: these inserts are absolutely imperative when
using any kind of soft tubing, such as vynil, ClearFlex, Taigon, etc...
Square cut
for updates
c. Spread a little bit of grease or soap (Vaseline,
dishwashing liquid, etc..) around the tubing. It helps
pushing the tubes in, particularly with Clearflex
tubing, which features a very “sticky” surface.
2. Preparing your Motherboard
3. MCW5000-PX™ water-block installation diagram
Page 1 of 2
Figure 1
Figure 2
Figure 4
Figure 3
d. Fully insert both tubes into the fittings. The tip of the plastic tube inserts should
be flush with the inlet and outlet openings, as shown in figure 4 above. Inserting the
tubes requires a firm push, accompanied by a twisting motion.
Remove the existing heat sink
Carefully clean the CPU.
Lightly coat the CPU with the provided thermal compound. Only a paper-thin coat is necessary. It should be applied using
preferably a razor blade, or a credit card, held between thumb and index at a 45-degree angle.
The MCW5000-PX water-block installs using Intel’s validated retention clips. Please use the retention clips, and
installation guide provided with your motherboard for installation of the water-block onto the CPU.
Figure 5
![](/html/69/6922/6922b01f0c7955def073151bde63924d4ce36292c066a133f1db8df1f2a1d431/bg2.png)
Swiftech Inc., 1703 E. 28
th
St., Signal Hill, CA 90755 T. (562) 595-8009 F. (562) 595-8769
4. Connecting the water-block(s) to the cooling circuit.
FAQS:
Inlet and outlet are interchangeable.
In Multi-Processor environments, optimal water-block performance will be achieved by connecting them in series (outlet
of one connected to the inlet of the other).
Recommended coolant: distilled water+ algaecides & corrosion inhibitors are mandatory (automotive antifreeze).
5. Final inspection
Once the installation is completed, it is always a good idea to test the circuit for leaks, prior to powering up the computer.
Troubleshooting help is available on our web site at www.swiftnets.com
, or by calling customer support at 562-595-8009.
Note concerning removal of the tubing
the MCW5000 block. With the collet firmly held against the face of the fitting, the tube can be safely pulled out. Do not attempt to pull
the tube out without pushing squarely against the collet. This may result in damaging the fitting. Further details for using quick-connect
fittings are also available here: http://www.johnguest.com/install_6.shtm#disconnect
: Push in collet squarely against face of fitting. A tube removal tool is provided with
: