The product is a comfort module with integrated radio
transmitter designed for demand-controlled climate
indoors within Swegon’s ventilation system WISE. The
product is used to ventilate, cool and heat premises exactly
as needed.
The product may not be used for anything other than its
intended use.
General
Read through the entire instructions for use
before you install/use the product and save
the instructions for future reference. It is not
permissible to make changes or modify this product other
than those specified in this document.
Contents
1 x WISE Parasol Zenith
1 x Instructions for use
Protective equipment
Always use appropriate personal protective
equipment for the work in question, in the
form of gloves, respirators, protective glasses
and helmets during handling, installation,
cleaning and service/maintenance.
Handling
Always use appropriate transport and lifting devices when
the product is to be handled to reduce ergonomic loads.
The product must be handled with care.
Installation
• Moist, cold and aggressive environments must be
avoided.
• Assemble the product according to this instruction and
applicable industry regulations.
• Install the product for easy access during service/maintenance.
• Avoid installing the product near a heat source.
• Check to make sure that the product does not have
any visible defects.
• Check that the product is properly secured after it has
been installed.
• Secure cables with cable ties.
• Check that all cables are properly secured in place after
installation.
Electrical safety
Permitted voltage, see Electrical data.
It is not permissible to insert foreign objects into the
product’s contactor connections or ventilation openings;
risk for short circuiting.
24 V isolation transformer to be connected should comply
with the provisions of IEC 61558-1.
Cable sizing must be carried out for cabling between the
product and the power supply source.
Disconnect the power supply when working on products
that are not required to run.
Always follow the local/national rules for who shall be
permitted to carry out this type of electrical installation.
2
Swegon reserves the right to alter specications. 20/06/2019
* Dimensions refer to WISE Parasol Zenith 600 with air connection ø125/ø160;
** When WISE SMB is installed in the face plate the height measurement (H) increases by 12 mm
* Dimensions refer to WISE Parasol Zenith 600 with air connection ø125/ø160;
** When WISE SMB is installed in the face plate the height measurement (H) increases by 12 mm
D
J
K
Weight
LengthTypeDim. Dry weightWater volume (l)
mmØ(kg)cooling heating
600A12512.91.08
600B12 513. 20.840.34
600A16014 .11.0 8
600B16 014.40.840.34
LengthTypeDim. Dry weightWater volume (l)
mmØ(kg)cooling heating
120 0A12522.62.4
120 0B12 522.91. 80.7
120 0A16024.62.4
120 0B16 024.91.80.7
LengthTypeSideDim. Dr y weightWater volume (l)
mm1, 2, 4Ø(kg)cooling heating
180 0A2, 420 030.53.8-
180 0B2, 420031.92.71.1
180 0A120030.73.8-
180 0B120032.12.71.1
Weights above are excl.:
WISE SMB (0.1kg).
Control plate (0.4 kg).
WISE CU (0.24 kg).
WISE Parasol Zenith 1800 (mm)
ABC**ØDEFGH**IJK
58418 22005065851192903681785 170 6
178 4
5921822005065851192903681785 170 6
1792
59818220050658511929036817851706
179 8
61718220050658511929036817851706
1823
62318 220050658511929036817851706
1867
642182200506585119290368178 5 170 6
1873
66718 220050658511929036817851706
1942
** When WISE SM B is installed in the fa ce plate the he ight measurement ( C and H) increases
by 12 mm
20/06/2019 Swegon reserves the right to alter specications.
3
Page 4
WISE Parasol Zenith b
Installation
Suspension with accessory SYST MS
Y
X
20mm
20mm
SYST MS
M8
c - c measurement
Placement of the bracket on delivery
Length of the unitc - c (mm)
600
120 0
180 0
Alternative placement of the suspension bracket
X
330 +10508 +10
930 +10508 +10
1530 +10508 +10
A2
A
A1
c - c (mm)
Y
4
Swegon reserves the right to alter specications. 20/06/2019
Length of the unitOut towards the corner In towards the centre
600
120 0
180 0
c - c (mm)
X ( A1)
398 +10262 +10
998 +10862 +10
1598 +101462 +10
c - c (mm)
X (A2)
Page 5
Accessory - Quick bracket for length 600 and 1200
Installation with quick bracket (accessory)
A: Installation with one centred threaded rod per quick
bracket.
B: Installation with two threaded rods per quick bracket.
WISE Parasol Zenith b
1A
M8
1B
M8
2
c - c measurement
Air connec tion sideShort sideLong side
Length of the unitc - c (mm)c - c (mm)
600
120 0
180 0
< 320
< 10209 0 0 -1020
< 15309 00-153 0
5
3
4
c - c
269 - 317
20/06/2019 Swegon reserves the right to alter specications.
5
Page 6
WISE Parasol Zenith b
Accessory - Centring when mounting in concealed T-bars.
Recommended number of plates per product.
Length of the
unit
6004
120 0 6
180 06-8
90°
6
Swegon reserves the right to alter specications. 20/06/2019
Page 7
Accessory - Fold-out coil
For easy access and cleaning stringent demands are made on hygiene.
1
The accessory, fold-out coil,
requires flexible hose connections
on the water side.
WISE Parasol Zenith b
6
7
8
2
3
10
9
4
5
20/06/2019 Swegon reserves the right to alter specications.
7
Page 8
WISE Parasol Zenith b
Water
Location water pipes
WISE Parasol Zenith 600 / 1200 / 1800
10350
210
210
Note that compression ring couplings
require support sleeves inside the pipes.
B2
Värme retur/
Heating return
B1
Värme tillopp/
Heating supply
Water connection with factory fitted valves
(In the example a WISE Parasol Zenith with air connection
on the long side)
942256009
A2
Kyla retur/
Cooling return
A1
Kyla tillopp/
Cooling supply
Water connection without factory fitted valves
(In the example a WISE Parasol Zenith with air connection
on the short side)
Connection sizes
ModelLengthFactory-fittedConnectionCoupling typeConnectionCoupling type
ACooling only600, 1200Actuator and valveReturnDN20 external threadsSupply pipePlain pipe 12 x 1.0 mm
BCooling /Heating600, 1200Actuator and valveReturnDN15, male threadSupply pipePlain pipe 12 x 1.0 mm
ACooling only1800Actuator and valveReturnDN20 external threadsSupply pipePlain pipe 15 x 1.0 mm
BCooling /
Heating
ACooling only600, 1200-ReturnPlain pipe 12 x 1.0 mmSupply pipePlain pipe 12 x 1.0 mm
BCooling /Heating600, 1200-ReturnPlain pipe 12 x 1.0 mmSupply pipePlain pipe 12 x 1.0 mm
ACooling only1800-ReturnPlain pipe 15 x 1.0 mmSupply pipePlain pipe 15 x 1.0 mm
BCooling /
Heating
180 0Actuator and valveReturnDN20 external threads/
DN15 external threads
180 0-ReturnPlain pipe 15 x 1.0 mm
Plain pipe 12 x 1.0 mm
Supply pipePlain pipe 15 x 1.0 mm/
Plain pipe 12 x 1.0 mm
Supply pipePlain pipe 15 x 1.0 mm/
Plain pipe 12 x 1.0 mm
8
Swegon reserves the right to alter specications. 20/06/2019
Page 9
Air
Selectable connection dimensions
Length
600YesYesNo
120 0YesYesNo
180 0NoNoYes
Selectable air connection sides.
When ordering, depending on the length, it is possible to
choose connection side 1, 2 or 4.
1
1
1
Diameter Ø
125160200
WISE Parasol Zenith b
Ø A
600
1200
1800
2
1200
Selectable connection side
Length
600YesNoNo
120 0YesYesYes
180 0Ye sYesYe s
Side
124
2
1800
1200
4
1800
4
Alternative air connection side
1. Unscrew two screws each from the spigot and cover
2. Change the location of the spigot and cover
3. Screw the spigot and cover in position each with two screws on
the new side.
20/06/2019 Swegon reserves the right to alter specications.
9
Page 10
WISE Parasol Zenith b
Commissioning
WISE Parasol Zenith is a part of the WISE system that demand-controls both air and water on a room level and guarantees
the highest level of indoor climate with minimum energy consumption. This means that when the installation and pairing
of the system is completed, no further trimming is required except for any adjustment of ADC.
The water connection is always placed on side 1.
The air connection, depending on length, can be
ordered on side 1, 2 and 4.
In the example to the right the air connection is on side 2.
2
q
p = [Pa]
(
i
)
k
q = k · √p [l/s]
i
pi [Pa]
q [l/s]
k = [k-factor]
ADC
Fan-shape
Side 1-4
Water
Air
1
2
4
3
-40˚
0˚
Examples of ADC settings
X-shape
40
+40˚
0°
-40°
10
Swegon reserves the right to alter specications. 20/06/2019
40°
Page 11
Connections
WISE Parasol Zenith b
2
1
Motor
WISE Parasol Zenith with factory-fitted components
1. WISE CU (Controller Unit)
2. Motor for integrated air damper
Factory fitted components as an option
• Sensor Module Advanced (WISE SMA), (Optional)
• Sensor Module Basic (WISE SMB), (Optional)
• Valves and actuators for cooling
• Valves and actuators for heating
• Temp. sensor
• Condensation sensor
LED - Explanation
Not connected “paired”
ColourTy p e
EnergizedWhitePermanent
Selected in TuneWISEWhiteFlashing, fast
Prepared to be added to
the system
To be added to the system WhiteFlashing, fast for 5 s
WhiteFlashing, slowly
WISE SMA
(Optional)
WISE SMB
(Optional)
Ground
24 V DC
0-10 V DC
WISE Parasol Zenith, connection.
6 7 8 9 10 +11-
POWER
1 2 3 4 5
24 V AC
Cooling
Valve actuator
1 & 2 (Optional)
There are different types of actuator.
For connection of the thermal actuator
such as Swegon’s actuator ACTUATORb,
see figure a.
When connecting the relay for connection
of three or more actuators, see figure b.
When connecting of the actuator with
0-10 V control signal (NOTE! 24 V DC
supply) see figure c.
Pressure tube
Heating
Temp. sensor
(Optional)
Condensation sensor
(Optional)
LED
STATUS
COM
Connected “paired”
ColourTy p e
Normal operationGreenPermanent
RestartBluePermanent for 10 s
InitiationBlueFlashing
Boosted max. flowOrangePermanent
Boosted min. flowOrangePermanent
Boosted water flowVioletPermanent
Boosted water flow/air flow Violet/Orange Alternating
Comfort alarm Red Permanent
Function alarmRed Flashing
Emergency mode Green/Red Alternating
Test mode Green/Orange Alternating
20/06/2019 Swegon reserves the right to alter specications.
a b c
Ground
Thermal actuator
24 V DC
3
2
ADAPT Relay
Relay for connection
of three or more
actuators
24 V DC
Ground
A1A2
1
-
+
24 V DC
0-10 V DC
Ground
Actuator with 0-10
V control signal
11
Page 12
WISE Parasol Zenith b
Use
Use TuneWISE for commissioning. Commissioning must be
performed by qualified and trained WISE service engineers.
Use SuperWISE for settings, reading alarms, etc. refer to
the documentation for SuperWISE II / SuperWISE II SC.
Trouble shooting
The product is not shown in the system:
• Make sure that the product is energized. (e.g. diode)
• Make sure that the product is paired.
• Make sure the product is in the right network.
The product shows incorrect/no air flow/pressure
• Make sure that the product is installed according to the
recommended distance.
• Check that there is air flow/pressure.
• Check that the measuring tube is mounted correctly.
• Check that the measuring tube is undamaged.
The product does not regulate the air flow/pressure
• Check that the motor has not become detached from
the damper spindle.
• Check that the motor works by turning the motor’s
release button, turn the damper spindle, release the
knob and then see whether the motor starts to move.
The product shows incorrect/no temperature
• Make sure the temperature sensor is not missing.
• Make sure that the temperature sensor does not hang
outside the product.
• Check that the temperature sensor is connected to the
right input.
The product shows incorrect/no VOC/CO2
• Make sure the VOC/CO2 sensor (WISE SMA) is not
missing.
• Check that the VOC/CO2 sensor is connected to the
right input.
Cleaning
Ideally the product should be cleaned twice a year by
vacuuming the coil to remove loose dust. In fibre dense
environments a more frequent interval is recommended.
A simple visual inspection of connections is recommended
when cleaning.
Avoid aggressive cleaning agents which may harm
painted surfaces. Normally a mild soap or alcohol solution
is fully adequate for cleaning. See also the maintenance
section in this instructions for use.
Cleaning of electrical components
• If needed, use a dry cloth to clean the components.
• Never use water, detergent and cleaning solvent or a
vacuum cleaner.
Service/maintenance
• In connection with a service, mandatory ventilation
inspection or cleaning of the ventilation system, check
that the general condition of the products looks ok.
Pay particular attention to the suspension, cables and
that they sit firmly in place.
• It is not permissible to open or repair electrical
components.
• If you suspect that the product or a component is
defective, please contact Swegon.
• A defective product or component must be replaced by
an original spare part from Swegon.
Materials and surface treatment
Sheet parts are made of galvanised sheet steel (Z275) and
pre-painted sheet SS-EN 10143+10346 - DX52D + ZA95,
NCS S 0500-N gloss 30+/-6%.
Disposal
Waste must be handled according to local regulations.
12
Swegon reserves the right to alter specications. 20/06/2019
Product warranty
The product warranty or service agreement will not be in
effect/will not be extended if: (1) The product is repaired,
modified or changed, unless such repair, modification
or change has been approved by Swegon AB; or (2) the
serial number on the product has been made illegible or
is missing.
Page 13
WISE Parasol Zenith b
Technical data
Max. radio frequency output:50 mW
Frequency band:2.45 GHz, IMS band
(2400 - -2483 MHz)
Temperature sensor: 0 - 50°C ± -0.5°C
Dynamic pressure sensor: 0 - 300 Pa
With WISE SMA
VOC sensor450 - 2000 ppm
RH sensor:0 - 100 RH%
IP class:IP20
Running time open/close (90°):120 s
Ambient temperature
Operation:0 – 50°C
Storage:-20 – +50°C
RH:10 - 95%
(non condensing)
CE marking:2006/42/EC (MD)
2014 /53 /EU ( RED)
2011/65/EU (RoHS2)
Electrical data
Power supply:24V AC ±15% 50 - 60Hz
Connections pipe dim.
Power:Screw terminal max. 2.5mm
Valve actuator:Push-in spring force connections,
max. 1.5 mm
Max. power consumption:See table below
WISE Parasol Zenith in standard
design:
WISE CU2.3
Damper motor (315C)2
Option:VA /
Ac t uato r, ACTUATORb7
WISE SMA0.8
WISE SMB0.6
Example:
WISE Parasol Zenith in standard design with the following
options:
Actuator for cooling and heating as well as WISE SMA, gives a
total power consumption of 4.3 + 7 + 0.8 = 12.1 VA
VA /
unit
unit
Standard
VA total
4.3
Declaration of Conformity
Swegon AB hereby affirms that
WISE Parasol Zenith with integrated radio, complies with the
essential characteristic demands and relevant regulations
specified in the following directives: 2006/42/EC (MD),
2014/53/EU (RED) and 2011/65/EU (RoHS2):
The following standards have been observed:
EN ISO 12100:2010
EN 60204-1:2006
EN 60730-1:2011
EN 60730-2-14:2009
IEC 60529:1992+A2:2013
EN 61000-6-2:2007
EN 61000-6-3:2007
EN 300 328 V1.9.2, V1.9.1,
V1.8 .1
EN 60335-1:2012+A11:2014
EN 60335-2-30:2009+A11
EN 62233:2008
2
2
Person responsible for this declaration:
Name: Robert Andersson, Factory Manager Arvika
Address: Fallebergsvägen 17, 671 34 Arvika, Sweden
Date: Arvika 20/ 06/2019
This declaration is applicable only if the product has been
installed according to the instructions in this document
and if no modifications or changes have been made on
this product.
References
www.swegon.com
Building Materials Declaration
WISE Parasol Zenith product data sheet
WISE System Guide
SuperWISE II / SuperWISE II SC User Manual
WISE Project Planning Guide - Heating, Cooling & Ventilation
and Electricity & Control
Safety of machinery - General principles for
design - Risk assessment and risk mitigation
Safety of machinery - Electrical equipment
of machines - Part 1: Generic standards
Automatic electrical control and control
unit for household use - Par t 1: Generic
standards
Automatic electrical controls for household
and similar use - Part 2 Particular
requirements for electric actuators
Degrees of protection provided by
enclosures (IP code)
Electromagnetic compatibility (EMC).
Generic standards. Immunity for industrial
environments
Electromagnetic compatibility (EMC).
Generic standards. Emission standard for
residential, commercial and light-industrial
environments
Electromagnetic compatibility and Radio
spectrum Matters (ERM) - Wideband
Transmission systems - Data transmission
equipment operating in the 2.4 GHz ISM
band and using spread spectrum
modulation techniques
Electric household appliances and similar
appliances - Safety - Par t 1: Generic
tandards
20/06/2019 Swegon reserves the right to alter specications.
13
Page 14
WISE Parasol Zenith b
Maintenance
1
2
3
4
6
14
Swegon reserves the right to alter specications. 20/06/2019
5
942428035
Loading...
+ hidden pages
You need points to download manuals.
1 point = 1 manual.
You can buy points or you can get point for every manual you upload.