SVS PLASMA ONE 4 User Manual

SVS PLASMA ONE 4 LIFT
INSTALLATION INSTRUCTIONS
(110V)
SVS, INC. Lifting Your Image
2513 Jenks Ave Panama City, FL 32405 www.svslifts.com
SVS Plasma One 4 Lift Installation Instructions Page 1 of 16
Tel: 850-522-4747 Fax:850-522-4739 sales@svslifts.com
Western Sales Tel: 720-283-6410 Fax:720-283-6424
SVS PLASMA ONE 4 LIFT
INSTALLATION INSTRUCTIONS
SECTIONS: Page
1. General Description.................................................................................................................................3
2. Features & Specifications/Standard Accessories...................................................................................3
3. Lift Warranty...........................................................................................................................................4
4. Preliminary Installation Checks.............................................................................................................5
5. Considerations for Lift Placement..........................................................................................................6
6. Lift Supporting Structure........................................................................................................................7
7. Lift Installation.........................................................................................................................................9
8. Electrical Connections.............................................................................................................................10
a. How to Use the Wall Plate Controller..........................................................................................11
b. Connecting to a Touch Screen Controller (External Controller)..............................................11
9. Accessory Installation..............................................................................................................................11
10. Mounting the Screen................................................................................................................................12
11. Lift Tilt Adjustment.................................................................................................................................12
12. Maintenance and Adjustments...............................................................................................................14
13. Troubleshooting........................................................................................................................................15
SVS Plasma One 4 Lift Installation Instructions Page 2 of 16
SVS PLASMA ONE 4 LIFT
12" TO CEILING
CLOSURE
4' FROM
CEILING TO BOT TOM
OF BOOM
NOTE: FOR REFERENCE ONLY­ACCESSORIES/PLASMA MAY EFFECT OVERALL DIMENSIONS
1. General Description:
The SVS Plasma One Series Lift is designed to support display screens up to 200 lbs. [90.72 kg] and provides an ideal solution for audio/video applications with restricted vertical ceiling spaces. This model only requires 14-inches [35.6 cm] of vertical space (stores the display screen horizontally above the ceiling). When required for viewing the screen pivots 90 degrees to 4-feet below the ceiling (the 4-feet [1.22 cm] refers to the distance from the false ceiling to the bottom of the boom).
Figure 1. shows the SVS Plasma One 4 Lift with Display Screen (Screen not included).
2. Features & Specifications
Minimum Vertical Ceiling Space Required for the lift: As little as 14-inches [35.6cm] (Allows 7-inches for screen & fixed
mount)
Figure 1. SVS Plasma One 4 Lift
Lift Positions:
Storage – Screen can be aesthetically stored above the ceiling when not in use.
Lowered – Screen lowers 4-feet for viewing.
Lowering Distance: 48-inches [121.9 cm] Lift Capacity: Up to 200 lbs [90.7 kg] Lift Weight: 100lbs [45.3 kg]
Maximum Screen Height: 55-inches [139.7 cm]
Voltage Material
110V/60Hz @ 1.5 Amps
Steel/Aluminum/Nylon
220V/50Hz@ .75 Amps
Steel/Aluminum/Nylon
Low Voltage Control
Wall Plate Controller supplied with lift
24VAC Contact Closure Control (latch to move lift)
Connects to lift using supplied 12-pin connector and 75-feet of cable (22 AWG/9 Conductor)
Precision Grooved Drum – Provides accurate and level tracking for consistent screen image.
Patented Fail Safe Drum Lock System – Insures safety in the event of mechanical failure. 100% safety record for 20 years of
manufacturing.
Quiet and Strong Motor – Extra quiet for meeting and presentations or simply for home use.
Redundant Limit Switches (up & down) – For secure and safe motor shutdown.
SVS Plasma One 4 Lift Installation Instructions Page 3 of 16
Standard Accessories:
PCC-1 Ceiling closure framework kit to be installed underneath the Plasma One boom and used to attach
customer supplied ceiling closure material (not supplied by SVS – SVS recommends 10 GA aluminum sheeting). On site fabrication and assembly required, ceiling closure dimensions will be based on the screen size. See Figure 9 to calculate the dimensions.
PCC-2 Complete customized ceiling closure. Includes framework and ceiling closure material cut to
the screen dimensions. Ceiling material is two pieces with seam between the Plasma One motor plate and screen plate. Supplied unpainted.
PPS-2 Plenum Shroud. Protective metal cover for lift and screen in plenum rated ceiling.
PMT-9 Fixed-mounting bracket used to attach the screen to the Plasma One boom (model varies with
screen used).
3. SVS PLASMA ONE LIFT WARRANTY
SVS, Inc. 's limited warranty only covers failures due to defects in materials or workmanship that occur during normal use. This limited warranty DOES NOT cover failures resulting from accident, misuse, abuse, neglect, mishandling, misapplication, faulty or improper installation and set-up adjustments, improper maintenance or alteration. Specific product warranties are as follows:
A 1-year parts and 90-day factory labor warranty applies to the following SVS products:
Plasma One Lift
Accessory #14 Floor Access Motor Control
A 1-year parts and 90-day factory labor warranty applies to the following SVS products:
Lift Motors
PCC-2 Closure Panel
Accessory PPS-2 Plenum Shroud
Accessory PMT-9 Screen Mount
A Return Material Authorization (RMA) number must be received from SVS prior to the return of any product. Products returned to SVS must be shipped adequately insured with freight prepaid and the RMA number clearly noted on the shipping label and crate. Items received freight collect or without RMA numbers clearly noted will be refused. Lift model, serial number, and proof of original purchase date may be required before warranty performance is rendered.
SVS Plasma One 4 Lift Installation Instructions Page 4 of 16
IMPORTANT: PLEASE READ THROUGH ALL INSTRUCTIONS
BEFORE BEGINNING YOUR INSTALLATION.
This Lift is designed to be used with a Wall Plate Controller, either automatically or manually controlled. The Wall Plate Controller features a key switch which can be placed in the “ON” or “OFF” positions for normal operation. The “Off” position disables the Lift. The “ON” position allows the lift to be lowered and raised using the Up/Down toggle switch.
WARNING
To prevent personal injury and property damage when servicing any part of the Lift drive system (electric motor/brake, drive chain/sprockets, steel lift cables, and/or drum lock assembly) the screen must be removed and the Lift's boom supported by straps, chain, or cable to prevent it from lowering unexpectedly while the drive system is being serviced.
IMPORTANT Please read all Accessory Installation Instructions before beginning your installation. If an Accessory PSS-1 Plenum Shroud is to be installed with the Lift. Please read the Accessory Installation Instructions before beginning your installation. The Lift support structure will need to allow enough space to install the mounting hardware for the Plenum Shroud.
TO AVOID CABLE SPILLS
Do not push the lift boom upwards once the Lift has been installed.
Make sure that there are no obstructions in the Lift's path. If the boom is lowered onto an
obstruction the cable will slack and spill over the cable drum.
4. PRELIMINARY INSTALLATION CHECKS
SVS recommends that the Lift support structure holds at least four (4) times the weight of the Lift and
screen combined. The rear support structure should hold three (3) times this amount due to the up thrust caused as the lift pivots down from the ceiling. The rear threaded rods should be reinforced approximately 12-inches up from the lift to avoid buckling under the up thrust. Always follow your local building codes.
Required space for the Lift, screen, and accessories should be considered prior to installation. Check for
obstructions that may prevent the Lift or accessories from being installed or operated.
Plan for necessary Lift low voltage control cabling, screen audio/video/control cabling, and power
connections.
Do not install the screen on the Lift until the Lift, hardware, and any accessories have been properly
installed and are operational.
This Lift has been adjusted with cables tightly packed on the cable drum and leveled for precise tracking
prior to being shipped from the factory. Do not remove the lift's shipping blocks until instructed to do so in Section 7.
All weight attached to the Lift must be centered on the lift's boom.
As a reminder, clear all persons and obstructions from the Lift's path during its operation. Keep fingers
and other objects away all moving parts. Technical personnel should always be present when the Lift is being serviced.
SVS Plasma One 4 Lift Installation Instructions Page 5 of 16
5. CONSIDERATIONS FOR LIFT PLACEMENT
Vertical Clearance:
Once the location of the Lift is determined, please verify that there is sufficient space above the
ceiling to accommodate the Lift, screen, and any accessories that you might be installing.
Ensure that nothing will interfere with the Lift operation.
The Lift needs a minimum clearance of 14-inches [35.6cm] of vertical height in the ceiling [the
Lift support structure and accessories not included. With this arrangement there will be 7-inches [17.8cm] of clearance for the screen and screen mount. The PCC-2 Ceiling Closure adds 3-inches [7.6cm] and the PPS-1 Plenum Shroud adds 2-inches [5cm] to the height of the application. See Figure 2 below.
Figure 2. SVS Plasma One 4 Side View
(shown with screen and PCC-2 Ceiling Closure)
Horizontal Clearance: Because the screen is stored horizontally, it may be necessary for the installer to
cut and re-support the main or load bearing beams. If so, please make sure that the ceiling will be appropriately modified to meet installation requirements and that the modifications will maintain the structural integrity of the ceiling. Always follow local and national codes in the modification of any structure. Please keep in mind that the ceiling opening will vary with the size of the screen. See Figure 3 for horizontal layout and Figure 9 to calculate the horizontal space required for the screen and lift.
Figure 3 SVS Plasma One 4 Top View
SVS Plasma One 4 Lift Installation Instructions Page 6 of 16
6. LIFT SUPPORTING STRUCTURE
Top Mounting: The Plasma One 4 can be mounted from the top by using four 3/8” threaded rods spaced
at 12 3/8 -inches [31.4 cm] wide by 23-inches [58.4 cm] deep. See Figure 4. The threaded rod must be supported by a rigid mount and should not exceed more than 12-inches [30.4 cm]from the supporting structure without cross bracing between the rods. If clearance allows, a “X-Y” or cross-supporting grid structure is strongly recommended as shown in Figure 5a & b. The “X-Y” structure allows the lift position to be adjusted side-to-side and front-to-back.
Figure 4. SVS Plasma One Mounting Locations
Side Mounting: The Plasma One 4 lift can be mounted from the sides by using the four (4) 3/8” - 16
bolts to attach the lift to the adjacent ceiling joist (or support structure). The lift top frame is designed to fit within a standard 16-inch [40.6 cm] space between the floor joist. Spacers should be added to the side of the lift top frame to avoid expanding the top frame when the bolts are tightened. The 14-inch outside dimension of the lift top frame should always be maintained. See Figure 4.
SVS Plasma One 4 Lift Installation Instructions Page 7 of 16
Figure 5a. Recommended Lift Support Structure for Flat Ceilings
Figure 5b. Recommended Lift Support for Beam Ceilings
SVS Plasma One 4 Lift Installation Instructions Page 8 of 16
Important
When attaching the Lift to a flat concrete ceiling, SVS suggest two (2) pieces of P1000T Unistrut (or equivalent) approx. 10-feet (3.04 m) long, to be installed on the ceiling first. Proper spacing between the two pieces will be based on the distance between the four (4) mounting holes located on the top of the Lift as shown in Figure 4.
You should use at least four (4) 1/2” bolts and anchors evenly spaced on each piece of Unistrut to distribute the weight of the supporting structure. Attach the two lower pieces of Unistrut to the upper two pieces of Unistrut using 1/2” threaded rods to the Unistrut, using Unistrut P3010 1/2” channel nuts in the channel, along with a locking washer and nut below the channel to lock into place.
IMPORTANT If you are installing an PPS-1 Plenum Shroud with the Lift, please read the Accessory Installation Instructions before beginning your installation. The Lift support structure will need to allow enough space for the Plenum Shroud mounting hardware
7. LIFT INSTALLATION
a. Preparation:
The Lift is shipped in a wooden crate in an inverted position.
Do not remove the Lift from the crate until you are ready to install it.
The Installation Instructions and Wall Plate Controller with control cable are located in a cardboard
box inside the crate.
Unbolt the Lift from the bottom of the crate to remove the lift from the crate and turn the lift upright.
b. Top Mounting
To prepare the ceiling opening for installing the Lift refer to the PCC-1/2 Ceiling Closure
Installation Instructions and Figure 9 to determine the size of the ceiling opening.
Raise the Lift into the ceiling and line up the four (4) mounting holes in the Lift's top frame with the
3
/8-inch threaded rods of the supporting structure. Make sure that there is a top nut and a flat washer on each threaded rod before the Lift is mounted. (Plenum Shrouds require additional hardware on the threaded rods before the Lift.)
Once the Lift's top frame has been inserted, add a hexnut to each threaded rod below the Lift frame.
Always leave the top nut loose to allow adjustments until the Lift is leveled.
Level the Lift's top frame side-to-side and front-to-back using the lower hexnuts on the threaded
rods.
Once the Lift is leveled, secure the Lift to the threaded rods by tightening the upper hexnuts. Do not
over tighten the fasteners as it could distort the Lifts top frame.
Plug the 12-pin connector of the Wall Plate Controller into the 12-pin socket on the Lift's gray
electrical box mounted on the Lifts top frame. The Wall Plate Controller includes 75-feet of cable and is shipped with the Lift. It is located in the cardboard box attached to the lid of the Lift's shipping crate.
Once the Lift is properly installed in the ceiling and leveled, you can remove the shipping blocks.
Remove the blocks by removing the screws and tie-raps holding them in place.
SVS Plasma One 4 Lift Installation Instructions Page 9 of 16
c. Side Mounting
The vertical placement of the lift must be very accurate when the lift is side mounted. Raise the lift into
the proper position.. The top of the lift should be 14-inches [35.5 cm]up from the ceiling without a ceiling closure and 15-inches up from the ceiling with a ceiling closure.
Make sure that the lift is in the proper position and level (side-to-side and front-to-back). Mark the four
(4) mounting hole locations (two (2) per side) onto the supporting structure. Remove the lift and drill four (4) 3/8-inch holes.
Important: Spacers should be inserted between the ceiling support structure and the lift top frame if the
gap between the support structure and the lifts top frame exceed 1/8-inch.
Once the supporting structure is ready, raise the lift back up into the ceiling and secure each mounting
hole with a 3/8-inch-16 fastener. Plug the 12-pin connector of the Wall Plate Controller into the 12-pin socket on the Lift's gray electrical box mounted on the Lifts top frame. The Wall Plate Controller includes 75-feet of cable and is shipped with the Lift. It is located in the cardboard box attached to the lid of the Lift's shipping crate.
Once the Lift is properly installed in the ceiling and leveled, you can remove the shipping blocks.
Remove the blocks by removing the screws and tie-raps holding them in place.
TO AVOID CABLE SPILLS
Do not push the lift boom upwards once the Lift has been installed.
Make sure that there are no obstructions in the Lifts path. If the boom is lowered onto an
obstruction the cable will slack and spill over the cable drum. If the cable spills over the cable drum and the Lift is not stopped the cable will back-wind onto the cable drum causing severe damage to the Lift and accessories.
8. ELECTRICAL CONNECTIONS
Electrical connections should be made at this time. The SVS Plasma One 4 Lift requires 110V/60Hz at 2.3 Amps and is supplied with a six foot power cord. The SVS Plasma One 4 Lift is controlled with a 24VAC Low Voltage Controller called the Wall Plate Controller. This controller can easily be connected to external controllers like Crestron, AMX, Extron, etc. The Wall Plate Controller is supplied with 75-feet of cable (22 AWG, 9 conductor).
Wall Plate Controller Information
Wire Color Connector Pin Function
Green 4 Down when 24VAC connected from Pin 1
Red 2 Up when 24VAC connected from Pin 1
White 1 24 VAC Out (Common) (can be measured between Pin 1 and Pin 7)
Black 7 Power LED Return (Ground)
Orange 8 Power LED+
1. Make sure that the area below the Lift is clear and that all cable are clear of the Lift.
2. Apply power to the Lift by plugging it into an AC Outlet.
SVS Plasma One 4 Lift Installation Instructions Page 10 of 16
a. How to use the Wall Plate Controller
VIE W FROM BA CK
(24vac )
+
-
(ON)
C
2
1
GRN
GRN
RED
UP
BLK
WHT
ORN
BLK
WHT
MO TOR POWE R ON
WHT
DOWN
ON-OFF-ON
RP2
(ON)
BLK
ORN
GRN
GRN
RED
WHT
321
4 5 6
9
8
7
12
11
10
1. To lower the Lift, turn the key switch to the ON position and press the toggle switch down. The Lift will lower as long as you hold the toggle switch down, the Lift will stop when it reaches the full down position and compresses the Down Limit microswitch.
2. To raise the lift, urn the key switch to the ON position and press the toggle switch up. The Lift will rise until the Up Limit microswitches are compressed. The Lift will rise as long as you hold the toggle switch up.
3. The Off position on the key switch disables the Lift.
4. The Power light on the Wall Plate Controller only comes on when the Lift is raising or lowering (Lift motor turning), not when power is applied to the Lift.
Important: The toggles switch on the Wall Plate Controller must be pressed to raise or lower the Lift, releasing the toggle switch stops the Lift. This is designed as a safety feature. The key switch is an extra precaution, when the key is removed, the Lift is secure.
b. Connecting a Touch Screen Controller (External Controller)
The simplest external controller connections are to use the White wire (pin 1) as the common and the Green wire (pin 4) for down and the Red wire (pin 2) for up. See Figure 9. Also:
1. Program a release of relays to stop the Lift on up and down positions
2. Program a time out after the normal runtime, 2 seconds max.
3. Program an exclusive lockout on up and down so that both cannot be activated at the same time. (Note: SVS Lifts have a lockout function that disables the Lift when it receives a up and down command at the same
Figure 6. Wall Plate
Controller
time. Removing one of the two commands releases the lockout condition.)
4. Hold relays on to raise/lower the Lift.
5. Never leave voltage on the up and down. Always program a release after the travel time has been achieved.
If you have any questions please contact SVS for proper wiring.
9. ACCESSORY INSTALLATION
Please refer to the accessory installation instructions located in the accessory shipping crates for specific instructions for each accessory. The Accessory PPS-1 Plenum Shroud require that hardware be added to the threaded rods supporting the Lift before the Lift is installed.
SVS Plasma One 4 Lift Installation Instructions Page 11 of 16
Figure 7. Wall Plate Controller Wiring
10. MOUNTING THE SCREEN
+
-
C
2
1
RED
PUR
BLK
BLU
ORN
MOTOR POWER ON
RP2
24V AC
UP
DOWN
TOUCH SCR EEN RELAY TWO
TOUCH SCR EEN RELAY ON E
RED
ORN
BLK
GRN
WHTWHT
GRN
YE L
BLK
321
4 5 6
9
8
7
12
11
10
After checking the Lift operation and all clearances you can install the screen on the Lift. A screen mount is required to attach the screen to the Lift.
You can use an Accessory PMT-9 Screen Mount from SVS or a standard wall type screen mount. For custom mounting option please contact SVS, Inc.
The Plasma One 4 boom features a plate used to attach the screen mounting bracket and must be drilled to accommodate at least four (4) 3/8-inch­16 nuts and bolts. The screen, screen mount,
and boom mounting plate must be centered in the ceiling opening.
Figure 8. Touch Screen Controller Wiring
Figure 9. PCC-1 & PCC-2 Ceiling Closure Sizing
SVS Plasma One 4 Lift Installation Instructions Page 12 of 16
a. Positioning the Boom Mounting Plate
The plate is attached to the boom by three (3) 3/8-inch-16 flathead Allen bolts and Unistrut nuts. The
rectangle nuts are set into the slot of the boom with their locking grooves set into the edges of the slot. Anytime that the nuts are loosened they must be checked to see that they are properly positioned with their locking grooves set into the edges of the slot.
To calculate the position of the boom mounting plate center divide the height of the screen in half and
add 3-inches [7.6 cm]. Measure down from the Up Limit Switch Reinforcement Plate on the boom and place the center of the screen mounting plate at this location. Tighten all three (3) 3/8-inch-16 flathead Allen bolts. See Figure 10.
b. Attaching the Screen Mount to the Boom Mounting Plate
Attach the screen mount (centered side-to-side and top-to-bottom) to the boom mounting plate by drilling four (4) 3/8-inch-16 holes in the boom mounting plate and screen mount. You may use existing holes in the screen mount if they will allow the attaching the screen mount to the boom mounting plate.
Secure the screen mount to the boom mounting plate by tightening all mounting hardware.
c. Installing the Screen on the Screen Mount
Install the screen onto the screen mount using the manufacturers instructions. Ensure that the screen is level and balanced. There should be appropriately 2-inches [5 cm] of clearance all the way around the screen.
Failure to maintain proper clearance could damage the screen, lift and/or ceiling.
Using the Wall Plate Controller, raise the lift toward the up position, stopping frequently to check all
clearances (screen, lift, and ceiling closure). Make sure that there are no obstructions in the path of the lift or in the ceiling cavity where the screen will be stored.
Screen cabling can be attached either to the boom or ceiling closure.
11. Lift Tilt Adjustment
The boom tilt is factory set to zero degrees. The screen will need to be installed first on the screen to determine the exact amount of tilt required. The tilt is adjusted by loosening the top 3/8-inch-16 bolt screwed on the microswitch bracket. The microswitch bracket is connected to a limit switch, when in contact with the boom stops the lift. There must be positive weight forward of the boom to achieve tilt. See Figure 11.
a. To Adjust Tilt:
Lower the lift.
Set the key switch to the OFF position.
Loosen the 3/8-inch-16 bolt and Unistrut nut on the down limit
microswitch bracket. See Figure 11.
Slide the down limit microswitch bracket forward to increase the boom tilt and backwards to decrease the tilt. The stop bolt will contact the boom.
SVS Plasma One 4 Lift Installation Instructions Page 13 of 16
When the tilt has been adjusted, tighten the 3/8-inch-16 bolt. Figure 10. Mounting Plate Center
Caution: If the tilt is set to more than 3 degrees and the boom does not compress the limit
microswitch, the motor will not stop which could cause the lift cable to slack or unwind from the cable drum and damage the screen and/or lift.
Figure 11. Lift Tilt Adjustment
12. MAINTENANCE AND ADJUSTMENTS
a. Maintenance
Inspect the Lift occasionally for any loose bolts or cable clamps.
Check the Drum Lock Assembly to see if the Drum Lock solenoid energizes and raises the Drum Lock
arm when you press the Down toggle switch to lower the Lift. At all other times the Drum Lock solenoid is de-energized and the Drum Lock arm stays in its down position. If the solenoid does not pull up, the microswitch will not allow the motor to turn when to lowering the Lift.
Check the Drum Lock pawl (white nylon piece) located on the Cable Drum. The pawl should move freely and drop when when it reaches the top of the Cable Drum's rotation, avoiding contact with the Drum Lock arm. If the drum rotates too fast, the pawl will swing out and catch the arm, locking the drum.
The Cable Drum Bearings (pillow block bearings) are pre-lubricated and do not require attention.
The Lift motor does not require attention. If the magnetic brake (part of the Lift motor) does not
hold properly, it should be replaced immediately.
WARNING
To prevent personal injury and property damage when servicing any part of the lift drive system (electric motor/brake, drive chain/sprockets, steel lift cables, and/or drum lock assembly) the screen must be removed and the lift's lower frame supported by straps, chain, or cable to prevent it from lowering unexpectedly while the drive system is being serviced.
SVS Plasma One 4 Lift Installation Instructions Page 14 of 16
13. TROUBLESHOOTING
All SVS Lifts are quality checked before they leave the SVS Factory and are fully operational. Shipping damage and installation oversights can cause problems to appear. Here are a few common and simple things to check. If at anytime you are unsure of the check, please contact SVS, we will be happy to help you troubleshoot your problem.
Symptom Possible Cause(s) Solution
Lift does not move Lift is not plugged into AC outlet or
AC outlet circuit breaker off.
Is the Wall Plate Controller connected to the Lift?
Check the Lift Power fuse located on the Lift Control Box
Lift power supply At the Wall Plate Controller
The Drum Lock Solenoid does not energize when you press the toggle switch down.
The Drum Lock Arm does not raise when the Drum Lock Solenoid energizes.
Make sure Lift is plugged in and circuit breaker is turned on.
Plug the Wall Plate Controller into the Lift Gray Control Box 12-pin Clinch-Jones connector.
If the fuse is blown see Blown Fuse Symptom.
terminal strip measure the AC voltage between the white and black wires, the voltage should be about 24VAC, if not contact SVS.
Disconnect one of the solenoid wires and measure the resistance across the solenoid terminals. If the resistance is less than 9.5 ohms replace the solenoid.
Check the Drum Lock Linkage between the Drum Lock Solenoid and Drum Lock Arm. If the Linkage is disconnected, reconnect. If broken, replace it.
Drum Lock microswitch damaged. Check Drum Lock microswitch.
Blown Fuse Power Transformer Shorted Unplug the lift, replace the fuse,
and measure across the two flat prongs of the AC plug. If the resistance is less than about 19-22 ohms, replace the transformer.
Drum Lock Solenoid Disconnect one of the solenoid
wires and measure the resistance across the black and green wire. If the resistance is less than 9.5 ohms replace the solenoid.
Lift does not lower but will rise Down Limit microswitches or
associated wiring damaged
Look for damage. Check for continuity from the Wallplate Controller to the Down Limit
SVS Plasma One 4 Lift Installation Instructions Page 15 of 16
microswitch.
Lift does not raise but will lower Up Limit microswitches or
associated wiring damaged
Lift stopped working after being connected to an external controller
If the external controller is closing the contacts between the White wire and the Red wire at the same time that it is closing the contacts between the White wire and Green wires, the Lift will go into a lockout, and will not work until one of the closed contacts is opened.
If the Wall Plate Controller and external controller are paralleled and they are closing different contacts the Lift will go into a Lock Out.
Look for damage. Check for continuity from the Wallplate Controller to the up limit microswitch.
Correct external controller programming
Place the Wall Plate Controller key switch in the off position when using the external controller. Turn off the external controller when using the wall Plate Controller
SVS Plasma One 4 Lift Installation Instructions Page 16 of 16