Dear customer,
TISA Konstruktion only offer high quality products with pleasing design and reliable operation, For us,
safety and high manufacturing standards are the most important and we ensure a long life product with
high efficiency and good heating economy. Even the best stoves require good handling and regulare care,
based on information and know-how. Please read these instructions carefully before lighting your first
fire.Potential mistakes such as unsuitable fuels, excessive heat levels,and inadequate maintenance can
rapidly canse damage which is not covered by our guarantee Please pay particular attention to the safety
instructions on the final page, since they help you to avoid possible damage and identify potential risks
Yourssincerely
TISAKonstruktionHB
Bear in mind that certain parts of the fireplace
become extremely hot in the course of the
combustion process,and take suitable precautions
if there are children and/or pets in the vicinity
.
You should also take into account that a space of
at least 1000 mm must be allowed between the
front of
the hearth and combustible furnishings
Study the user instructions carefully
before using the stove and remember that
the installation must be first approved by
a chimney sweep
The stove and the chimney must
be arranged in a way that ensures
that they cannot
start a fire in
adjoining fixtures or parts of
the
building.The flue must be
installed in
a manner which
permits chimney-sweeping
for the
full flue length, and with ready
access to cleaning doors
.
Elipse 1 – Elipse 2 – Elipse 3 – Elipse 4 – Elipse 5 – Elipse 6 – Elipse 7 – Elipse 8
General................................................pages 4-5
Assembly.............................................pages 6-7
Technical information........................ pages 8-9
Dimensions &con. heights…........pages 10-15
Instructions for use and maintenance..page 16
-manufacturer s assurance-planning
application
-inspektion
-guarantee
-chimney
-distance from combustible surfaces
-load-bearing structure
-fireplace base
-what is included
-envirinmental approval
-transportap attachments
-receipt of goods
-cool hands
-outdoor air connection
-fan
-the right location
-order of assembly for top connection
-ball/plummet stop
-connection to existing masonry
chimney
-cutting hole in masonry chimney
-design specifications
-data
-accessories/options
-distance from wall surfaces
-output controll
-how to open the door
-asc disposal and grate controls
-Elipse 1
-Elipse 2
-Elipse 3
-Elipse 4
-Elipse 5
-Elipse 6
-Elipse 7
-Elipse 8
-Elipse 9
-Elipse 10
-Elipse Low Base
Elipse 1 – Elipse 2 – Elipse 3 – Elipse 4 – Elipse 5 – Elipse 6 – Elipse 7 – Elipse 8
Manufacturor’s assurance
This product has been manufactured in
accordance with the type approval
documentation, of which the instructions for
assembly, use and maintenance form an intrinsic
part.
Planning application
Before commencing a new installation of a stove
and chimney in an area covered by town
planning, you must notify the local planning
authority. The planning and building office in your
local municipality will provide further information.
Inspection
When installation has been completed, it must
always be inspected by a chimney sweep before
the stove is used, irrespective of whether it is
connected to a new or an existing chimney.
Guarantee
Before using your stove, you should read the
terms of the guarantee (see our website),
indicating the requirements that must be met. If
the guarantee undertakings are to apply.
Chimney
The diameter of the flue must be at least 150 mm,,
and we recommend a minimum flue height of 3,5
moires, measured from the stove flueconnectionpoint. Follow the chimney supplier’s
assembly instructions carefully. If you intend to fit
your stove to an existing masonry chimney, it
should first be inspected by a chimney sweep to
check that it is in good order. The stove can be
connected at 45’’ angle, or at a 90’’ angle, straightback with a cleaning door to a chimney approved
for a maximum flue gas temperature of 350C.
Distance to combustible wall
Theminimum distance from a combustible wall
surface is 500 mm at the sides and 100 mm at the
rear (see diagram at page 8). The minimum
distance from furnishings in front of the stove is
1000 mm. If the stove is placed against a masonry
chimney or a firewall installation, the space behind
the stove may be reduced to 50 mm.
Structural support
A stove with a chimney does not normally require
special foundations and can be placed on an
ordinary floor supported by wooden rafters. If you
are uncertain, contact a chimney sweep for
further advice and instructions.
Fireplacebase
The stove must be placed on a fireplacebase
consisting of concrete, natural stone, brick or
glass with a thickness of at least 50 mm, or sheet
metal with a thickness of 0,7 mm. The base must
cover the entire surface under the stove and
extend at least 300 mm in front of the stove and
100 mm at the sides. A fireplace base in sheet
metal or glass is available as an optional extra.
What’s included?
The delivery includes the stove and inserts
for a top or rear connection. Options include
a fireplace base and a connection kit for an
existing chimney. An outside airfeed
connection and a fan are also offered as
optional extras
Enviromental approval
These instructions are also valid for
product-type and enviromental approval
documentation purposes.
Transport
When delivered the baffle plate is
attached with a special glue to provide
from falling or breaking. The glue will
dispensary when the first fire is lit. If you
wish to remove the baffle before that,
perhaps as the chimney sweeper does
the inspection, just use a carpenter’s
knife to carefully loosen the two glue
dots, one on each side of the baffle.
Elipse 1 – Elipse 2 – Elipse 3 – Elipse 4 – Elipse 5 – Elipse 6 – Elipse 7 – Elipse 8
Cool hands
The stove glove is supplied and equipped
with a practical magnetic attachment.
Always use the glove when you’re opening
the door to put on more logs, since the fire
do or handle may be hot. Don’t store the
glove on the stove while heated. Don’t use
the glove inside the stove.
Outdoor air connection
The air consumed in the combustion process has to
be replaced, particularly in well-insulated buildings.
The air feed to the hearth may be direct, via an
outdoor air connection, or indirect, via a vent in an
external wall. In the case of an outdoor air feed, the
stove connection point has a diameter of 60 mm. If
the air channel passes through a warm area it should
be insulated to pre-vent condensation. The minimum
mineral-wool insulation thickness is 30 mm, with
plastic foil on the outside. Anti-condensation lagging
may also be used.
The outside air hose can be directed straight down
through the floor or directed through the lower hole at
the back of the stove and through the wall. See the
picture at the top of this page.
Fan (optional extras)
See seperate manual for fan assembly.
Stone base unit (optional extras)
The stone-base unit,, and the cast-iron base unit,
which are optional extras, increases the connection
height by 40 mm.
Receiving of goods
The product may have been damaged in
transport,
although this may not be
apparent from the external
packaging
. It is
important that you inspect the stove
carefully
and report any damage to the
transportcom
pany within seven days.You
should note visible dama
ge immediately on
the delivery note,in connection with receipt
of the goodson delivery, the stove is
attached to a pallet with screws,under a
wooden frame, and is
covered with sheet
plastic.Take precautions to avoid
damage
when unpacking and assembling the
stove.
The connection hose should be insulated.
Thestovewillbedeliveredlikethis
Find the collar to the outdoor air supply
inside the
log compartment.
A stove glove 'aka' cool hands