A
Brown
White/Brown
Green
White/Green
Orange
White/Orange
Blue
White/Blue
Brown
White/Brown
Orange
White/Orange
Green
White/Green
Blue
White/Blue
568A Wiring
Ports 2, 4
Ports 1, 3, 5
568B Wiring
MediaMAX
TM
Gateway Termination Module Installation Instructions
MXM-521: Voice and data termination module
Mount module to enclosure backboard.
a) Position module with mounting pins aligned to grid holes.
b) While holding the module in place, pull each pin plunger OUT then
rmly push the plunger IN to secure the module to the backboard.
Terminate incoming copper service lines (green) for voice/ data.
a) Strip 1.5 in. of outer jacket from the cable.
b) Insert wires into green toggle actuator holes according to
selected wire conguration.
c) Insert the white/blue wire in the left hole.
d) Insert the blue wire in the right hole.
e) Repeat steps c and d with the orange, green, and brown wires.
f) Close toggle actuator to terminate each wire pair.
Note: Maintain twist as close to the toggle actuator as possible.
Terminate incoming ber service line directly to ONT.
Terminate outgoing cables
a) Terminate voice-only output cables to gray terminals as shown on
module
b) Terminate voice/data output cables to yellow terminals.
Connect module to media gateway/ONT as shown.
1
2
3
A
4
Gateway voice/data module (tool-less)
Designation label
Instructions
Package Contents
B
5
1 2
4
4

Media
Gateway
Voice Data
to
Outlet
to
Outlet
to
Outlet
Incoming Copper
ONT/
Media
Gateway
Voice Data
to
Outlet
to
Outlet
to
Outlet
Incoming
Fiber
B
Copper Installation
Fiber Installation
100072-00 Rev B
1001 East Highway 212 • Hector, MN USA 55342 • suttlesolutions.com
Toll Free: 1 (800) 852-8662 • Local: (320) 848-6711 • Fax: (320) 848-6218
Specifications subject to change without notice. Copyright 2017.
MediaMAX
TM
Gateway Termination Module Installation Instructions
Read and understand all instructions. Follow all warnings, cautions, and instructions marked on the product.
Do not use this product near water,--e.g., near a bath tub, wash basin, kitchen sink, wet basement, or near a swimming pool.
Never push objects of any kind into this product through openings, as they may contact dangerous voltages
Important Information
Never install communications wiring or components during a lightning storm.
Never touch uninsulated wires or terminals unless the wiring has been disconnected at the network interface.
Never install communications components in wet locations unless the components are designed specifically for use in
wet locations.
Safety Information
SAVE THESE INSTRUCTIONS