Sussex Taps VSMC-15, VSMC-06, VSMQ-13, VSMQ-15, VSMC-16 Installation Guide

...
Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003
INSTALLATION GUIDE
Recommended working water pressure 30 0-50 0 kpa. Maximum water temperature is 65 deg.c.
IMPORTANT NOTE: To provide proper function, the Sink Mixer must be installed with the handle to the RIGHT-HAND side of the operator.
INSTALLATION GUIDELINES
҃ The Mixer is supplied assembled, only the Fixing nut and the Brass
Clamp need to be removed. ҃ Decide if the Optional Base Flange is to be used. ҃ If using the Optional Base Flange discard the smaller Base O Ring. ҃ Add the base Flange to base of Mixer and attach the Flexible Hoses
to the Mixer Hose extensions. ҃ In some cases the Flexible Hoses may need to be fed through from
under the mounting surface and then attach. ҃ Once the Flexible Hoses have been secured, lower the Mixer onto
the mounting surface. ҃ Working from underneath the mounting surface fit Clamp and
Fixing Nut. ҃ Before fully securing the Mixer ensure that the Base O Ring is
intact and the Mixer is centered over the mounting surface hole . ҃ The Mixer mounting surface must be completely water-tight. ҃ Connect the Hot and Cold Flexible hoses to the corresponding
1/2”BSP water feed lines. ҃ The 1/2” connection of the Flexible hoses have a conical seal,
ensure the mating threads are cut square and burr free. ҃ Isolating stop valves are recommended with all installations.
(not supplied) ҃ Ensure all fittings and connections are water-tight.
NOTE: Optional Base Flange must be used when the clearance hole for mounting the Mixer exceeds 35mm. If the mounting hole clearance exceeds 45 mm a custom made Base flange will be required.
Voda Sink Mixer Right Hand
Product code: Available opons: VSM Sink Mixer VSMC Sink Mixer Curved VSMQ Sink Mixer Square VSMCSSRH Sink Mixer Curved 316 S/S VSMQSSRH Sink Mixer Square 316 S/S
Sink Mixer
Body
Sink Mixer
Stand
NOTE: Mixer handle to be RIGHT-HAND side of the operator.
Handle
Pin
Handle
Body
Base Flange
PLUMBER NOTE
҃ On-site testing using higher water pressures must be conducted
with the Mixer in the closed position. (STATIC TEST) ҃ Under no circumstances is the Mixer to be opened when
exceeding the maximum stated water pressure. ҃ At the completion of testing, do not relieve any high water
pressure by opening the Mixer. ҃ Exposing the internals of the Mixer Cartridge to higher than
Flexible Hose
Surface
Fixing
Nut
Hose extension
(Do not remove)
32 - 35mm
Clamp
sussextaps.com.au
sussextaps.com.au
Loading...