![](/html/fd/fd40/fd40a40954a7cd819648f527de1f7ea6954e3720a0a293896a092fc1264da130/bg1.png)
71030i DC-DC CONVERTER
1. It is recommended that the batteries be disconnected prior to installation.
Reconnect the batteries after the installation is complete
2. Mount converter in a convenient, well ventilated area. Use 16AWG wire
with a voltage rating of at least 150V to connect to power source. Use
14AWG for the ground and 12V outputs.
3. Terminal #4, #5, and #6 (“GND 12V”): Make ground connections first.
Using 14AWG all three pins must be used for ground connection.
4. Terminal #7 and #8 (“SW 12V”): Using 16AWG connect both pins to 12V
loads. These pins are switched On/Off with activation of Ignition, Terminal
#3.
5. Terminal # 3 (“IGN”): Using 16AWG connect to a switched 12V source. For
always ‘ON’ operation this pin can be connected directly to 12V source.
6. Terminal #9 and #10 (“UNSW 12V”): Using 14AWG connect both pins to
12V loads. These terminals supply continuous 12V power.
NOTE: THE SUM OF TWO OUTPUT LOADS (12V SWITCHED AND
12V UNSWITCHED) CANNOT EXCEED 30 AMPS.
7. Terminal #12 (“72Vin, 80Vin, 96Vin”): Using 16AWG with a minimum
rating of 150V, connect to positive terminal of power source.
8. Terminal #1 (“GND POWER SOURCE”): Using 16AWG with a minimum
rating of 150V, connect to negative terminal of power source.
INSTALLATION INSTRUCTIONS
IGNITION
SWITCH
EV BAT -
72V, 80V
96V
NOMINAL
BATTERY
BANK
1
CONVERTER CONNECTOR
12
6
7
EV BAT +
AMP
30
AMP
30
TYPICAL INSTALLATION WITH SWITCHED & UNSWITCHED LOADS
(Total load must be less than 30A)
LITHO IN USA
Usually Ignition switch is
already wired into vehicle
Use all 3 pins for GND
TO 12V SWITCHED LOADS
TO 12V UNSWITCHED LOADS
INSTRUCTION 180127A 0404