Operators Manual
Doc #P10226 Rev 1.9
SURE-FI, INC. | www.sure-fi.com
Quick Startup:
The two units that are packaged together (banded) are factory paired and
will only communicate with each other.
Check initial operation
Connect the 9V battery (included) to the 9V power cable (included) and plug the two-position
connector in to the Wiegand Controller / Remote Interfaces at the ‘12V’ and ‘GND’ positions on the
bottom edge connector. Once both units are powered up, the green POWER LED should be ON
steady on each unit. Press and quickly release the ‘TEST’ button to test communication between
the two units. One or more of the blue LEDs should light up for one second to indicate that
successful communication has occurred.
Perform a Range-Test from the desired install locations
With the 9V batteries plugged in to each of the units, place them at the desired install location
points and perform a Range-Test by pressing and quickly releasing the ‘TEST’ button. The received
signal strength is displayed for one second on the six blue LEDs with the bottom LED indicating the
minimum signal strength and all six LEDs indicating maximum signal strength.
Connect to permanent power
Before connecting each unit to the permanent power source, ensure that it is a 12VDC supply that
can source at least 1 ampere to the unit. Connect the power at each unit and perform several
Range-Tests to check for adequate input power.
Wire the input and output functions
Using the wiring examples on pages 21 – 27 for reference, wire the required devices at each unit.
SURE-FI, INC. | www.sure-fi.com
Radio Transceiver Specifications
Controller Interface – Top & Bottom Connector pin descriptions
Remote Interface – Top & Bottom Connector pin descriptions
Providing Power to the Controller and Remote Interfaces
Battery Backup Charging and UPS Functionality
POWER LED and BATTERY LED Diagnostics
Jumpers JP1 and JP2 (Remote Interface only)
Wiegand Port (D0, D1, LED), Wiegand LED
Auxiliary (AUX IN / AUX OUT)
Test (Range Test) Push Button
LEDS: Power, Battery, Tx, Rx
Connector plug information
Chain Multiple system pairs for extended range
Sure-Fi APP – downloading, installing, connecting
Sure-Fi APP – Firmware Updating
Sure-Fi APP – Changing the name of the unit, Configuration of the Wiegand
LED
Sure-Fi APP – Setting System Heartbeat, Relay Defaults, Timeout, and Alert
Relay(s)
Pg. 19
Troubleshooting, Wiegand problems, manually testing relays
Pg. 21 – 27
FCC and Industry Canada Regulatory Statements
Table of Contents
SURE-FI, INC. | www.sure-fi.com
Figure 1: Device Overview
Figure 2: Connecting Power and Backup Battery
Figure 3: Jumpers JP1/JP2
Figure 4: Diagram of Power Input, +VBUS, and JP1/JP2 functionality
Figure 5: Chain multiple systems, wiring diagram
Figure 6: DIN clips pressed outward for screw mounting
Figures 7 & 8: Top and Bottom DIN Rail Screw Mount locations
Figures 9 & 10: Wiring a Wiegand device
Figures 11 & 12: Wiring a Mag-Lock that is powered with a wet relay contact
Figures 13 & 14: Wiring a Door Position Sensor to Relay 3 (R3 IN)
Figures 15 & 16: Wiring a Request to Exit (REX) button to Relay 4 (R4 IN)
Figures 17 & 18: Wiring example for Door Strike, REX button, and Wiegand
device
Figures 19 & 20: Wiring example for a Maglock, REX button, and Wiegand
device
Pg. 26
Figures 21 & 22: Wiring a Gate Operator, REX button, and Wiegand device
Figure Reference Guide
SURE-FI, INC. | www.sure-fi.com
Wiegand Bridge system: includes 1 ea. DS004-CONTROLLER and DS004-REMOTE
Wiegand Controller Interface
Wiegand Remote Interface
Note: if the product part number includes ‘REV2’ such as ‘DS004-REMOTE
REV2’, then the relays are solid state type with the specifications noted on
page 6. Additionally, the relay outputs have on-board Surge Protectors which
eliminates the need for the use of the external ones that are supplied with the
REV1 systems.
Part Numbers
Product Overview
The Sure-Fi DS004 Wiegand Bridge System consists of two units that are factory paired and ready
to use out of the box with no configuration required. These units are the Controller Interface, Model
DS004-CONTROLLER, and the Remote Interface, Model DS004-REMOTE. The system provides a
wireless connection (bridge) from a remote location (door, gate, or relay device), to the controller
location, such as an Access Control Panel. The Controller Interface wires to the Access Control
Panel and communicates wirelessly to the Remote Interface, which is placed near any peripheral
Wiegand device (card reader / keypad / receiver) and/or any relay/switch activated device. Each
DS004-BRIDGE System consists of one Wiegand channel, two relay outputs and two relay inputs
for functions such as door monitor sensors/request to exit inputs or any other relay-controlled
function. Each unit has two relay outputs that correspond with the two relay inputs from the
paired unit. The relays can be used independently and exclusively, meaning that it is not necessary
to use the Wiegand input to use the relays. The Sure-Fi App provides for configuration, diagnostics,
and field firmware updates.
Features
• Includes complete wireless solution from Remote location (reader/door) to Controller location
• Range: up to 1 mile through obstructions and greater than 50 miles line-of-sight
• Chain multiple system pairs for extended range
• One Wiegand port (compatible with any Wiegand protocol up to 64 bit)
• Two relay outputs per side NO, NC, COM terminals (wet contacts available on the Remote
Interface)
• Two relay control inputs per side, i.e. Request to Exit input (REX), Door monitor input (DPS), etc.
• One Auxiliary digital input/output (0 to 5V input/output)
• Backup Battery charger and UPS function
• DIN rail mount or direct wall mount
• Sure-Fi APP connects via Bluetooth for diagnostics and firmware updates
SURE-FI, INC. | www.sure-fi.com
General Specifications
Operating Voltage: 12VDC (9VDC to 15VDC)
Operating Current: @ 12VDC: 0.08A (idle), 0.3A (transmit)
Operating Power: 3.6 Watt (peak)
Battery backup: 12V sealed lead acid (SLA) type only (not included)
Battery Low Threshold: < 11VDC
Battery Charge Voltage: 13.75V maximum at standby charge
Battery Charge Current: Trickle charge, 0.125A maximum at low battery voltage level.
Relay Inputs (each unit): Two relay control inputs: dry contact or digital 0 to 5VDC
interface
Relays (both units, REV 1 type): Two Form C relays, 2A 220VDC / 250VAC. Maximum
switching power 60W/ 125VA. Maximum allowable combined current of both
relays 3A
Relays (Remote REV 2 type): Two Form C solid state relays, 2A 30VDC / 30VAC
Note: Maximum allowable combined current is 3A
Range: Up to 1 mile through obstructions. Greater than 50 miles line-ofsight
Can chain multiple system pairs for extended range
Encryption: AES128
Operating Temperature: -40°F to +185°F (-40°C to +85°C)
Storage Temperature: -67°F to +257°F (-55°C to +125°C)
Humidity: 0 to 95% non-condensing
Dimensions (L x W x H): 3.54” x 4.23” x 1.28” (90mm x 107mm x 32.5mm)
DIN mount type: 35mm DIN rail (DIN46277-3) / (DIN35)
Degree of Protection: IP20 to IEC/EN 60529
Radio Transceiver Specifications
Transmit Power: 1 Watt (30dBm)
Frequency Band: 902 – 928MHz
Channels: 72 (Frequency hopping)
Receiver Sensitivity: -133dBm
Link Budget: 163dB
SURE-FI, INC. | www.sure-fi.com
Device Overview
Figure 1: Device Overview
SURE-FI, INC. | www.sure-fi.com
R4 NC: Relay 4 Normally-Closed terminal
R4 COM: Relay 4 Common terminal
R4 NO: Relay 4 Normally-Open terminal
R2 IN: Relay 2 control: activates Relay 2 on
Remote unit
R1 IN: Relay 1 control: activates Relay 1 on Remote
unit
R3 NC: Relay 3 Normally-Closed terminal
R3 COM: Relay 3 Common terminal
R3 NO: Relay 3 Normally-Open terminal
BAT+: Battery backup positive terminal ’+’ connection. 12V Sealed Lead Acid (SLA)
type battery only.
GND: - DC input (Wiegand Ground connection)
D0: Wiegand D0 connection
D1: Wiegand D1 connection
LED: Device LED connection
AUX-OUT: This is an output on the CONTROLLER INTERFACE. It corresponds with
input AUX-IN on the REMOTE INTERFACE.
Controller Interface - Top connector
Table 1:
Controller Interface - Bottom connector
Table 2:
SURE-FI, INC. | www.sure-fi.com
R2 NC: Relay 2 Normally-Closed terminal
R2 COM: Relay 2 Common terminal
R2 NO: Relay 2 Normally-Open terminal
R4 IN: Relay 4 control: activates Relay 4 on
Controller unit
R3 IN: Relay 3 control: activates Relay 3 on
Controller unit
R1 NC: Relay 1 Normally-Closed terminal
R1 COM: Relay 1 Common terminal
R1 NO: Relay 1 Normally-Open terminal
BAT+: Battery backup positive terminal ’+’ connection. 12V Sealed Lead Acid (SLA)
type battery only.
VBUS: + voltage output for Wiegand device (See Figure 4)
GND: - DC input (Wiegand Ground connection)
D0: Wiegand D0 connection
D1: Wiegand D1 connection
LED: Device LED connection
AUX-IN: This is an Input on the REMOTE INTERFACE and corresponds with the output
AUX-OUT on the CONTROLLER INTERFACE.
Remote Interface - Top connector
Table 3:
Remote Interface - Bottom connector
Table 4: