SUPREME FUSION 24, FUSION 18 Owner's Manual

FIREPLACE INSERT, MODEL «FUSION 24»
Tested and listed to ULC S628 and UL 1482 by an accredited lab.
This unit is certified to comply with Phase II particulate emission standards from the Environmental Protection Agency.
OWNER’S MANUAL
- OPERATION
Important: Keep the owner’s manual for future use
This product is proudly manufactured in North America by:
3594 Jarry East Montreal, QC, H1Z 2G4 Tel: (514) 593-4722 Fax: (514) 593-4424
www.supremem.com
Revised: August 16th, 2016
Table of Contents
1. SAFETY…………………………………………………………………………………………………1
2. COMPONENTS.……………………………………………………………………………………….2
2.1. Overall Dimensions..……………………………………………………………………….....2
2.2. Combustion Air Control……………………………………………………………………….3
2.3. Cold Hand Key…………..…………………………………………………………………….3
2.4. Secondary Air Control……………………………………………………………………...…3
2.5. Chimney Sweeping Cap……………………………………………………………………...3
2.6. Door…………………………………………………………………………………………….4
2.7. Removable Ash Lip…………………………………………………………………………...4
2.8. Blowers…………………………………………………………………………………………4
2.9. Surround……………………………………………………………………………………….4
2.10. Adjustable Circulating Chamber…………………………………………………………….5
2.11. Adjustable Legs……………………………………………………………………………….5
2.12. Liner Adaptor………………………………………………………………………………….5
2.13. Metal Tag……………………………………………………………………………………...5
2.14. Serial Number………………………………………………………………………………...5
3. INSTALLATION INSTRUCTIONS…………………………………………………………………..6
3.1. Preparing the Firebox for Installation……………………………………………………….7
3.2. Liner Installation………………………………………………………………………………7
3.3. Adjustable Circulation Chamber…………………………………………………………….7
3.3.1 Assembly……………………………….………………………………………………7
3.3.2 Installation……………………………….……………………………………………..7
3.4. Liner Adaptor Installation…………………………………………………………………….8
3.5. Firebox Installation……………………………………………………………………………8
3.6. Power Cord Side Reversal…………………………………………………………………..8
3.7. Surround Installation………………………………………………………………………….9
3.8. Installation in a Factory Built Fireplace……………………………………………………..9
3.9. Clearance to Combustible…………………………………………………………………..10
4. OPERATION INSTRUCTIONS……………………………………………………………………..11
4.1. Fuel…………………………………………………………………………………………….11
4.2. First Fires……………………………………………………………………………………...11
4.3. Operating the Combustion Air Control……………………………………………………..11
4.4. Starting a Fire……………….………………………………………………………………..12
4.5. Adding a New Load of Wood………………………………………………………………..13
4.6. Barbecue Grill…………………………………………………………………………………13
4.7. Fan Operation………………………………………………………………………………...14
5. TROUBLESHOOTING……………………………………………………………………………....15
5.1. Smoking……………………………………………………………………………………….15
5.2. Over Firing…………………………………………………………………………………….15
6. MAINTENANCE………………………………………………………………………………………16
6.1. Disposal of Ashes…………………………………………………………………………….16
6.2. Chimney Maintenance……………………………………………………………………….16
6.3. Cleaning of Glass…………………………………………………………………………….17
6.4. Replacement of Gasket……………………………………………………………………...17
6.5. Replacement of Glass……………………………………………………………………….17
6.6. Door Latch Lubrication……………………………………………………………………….18
6.7. Paint……………………………………………………………………………………………18
6.8. Removal of Firebox…………………………………………………………………………..18
6.9. Replacement Parts…………………………………………………………………………...19
7. WARRANTY…………………………………………………………………………………………..21
WARRANTY REGISTRATION
Please register your SUPREME product online at http://www.supremem.com/registration.php to ensure
full warranty coverage. Proof of purchase is required for all warranty claims.
1. SAFETY
CAUTION:
Do not connect this unit to a chimney flue serving another appliance. Do not connect to any air distribution duct or system. Never use chemicals to ignite the fire. Never burn waste or flammable fluids (such as gasoline, naphtha, or engine oil). Only burn dry natural cordwood. Never leave the unit unattended with the door open or unlatched. Only refuel this unit when the wood is reduced to embers. Always keep the door closed during operation. Do not operate this unit with a fireplace grate. Do not install an unvented gas log set into the firebox. Do not install this unit in a mobile home. Do not clean or service the unit while it is hot. Allow proper air flow by keeping the louvers/openings clear of any obtrusions.
Note: Failure to respect the above cautions may cause damages to the unit, damages to personal property, bodily harm and will void the warranty. “This wood heater needs periodic inspection and repair for proper operation. It is against federal regulations to operate this wood heater in a manner inconsistent with operating instructions in this manual.”
1
SUPREME FIREPLACES INC. congratulates you on purchasing a FUSION wood burning fireplace insert. This insert complies with the ULC S628 and UL 1482 standards. In addition, this wood insert is certified to comply with Phase II particulate emission standards from the US Environmental Protection Agency.
SAFETY NOTICE: Carefully read this manual before installation and operation of this insert. If not properly installed, a house fire may result. To reduce the risk of a fire, follow the installation instructiosn. Failure to follow instructions presented in this manual can lead to property damage, bodily injury or even death. Alterations or modifications made on the unit or the installation is strictly forbidden as it may predispose the user to hazardous risks. Contact your local building or fire officials for restrictions and installation inspection requirements in your area and the need to obtain a permit.
WARNING: This unit is hot during operation; keep children, pets, flammable liquids, or combustible materials at a safe distance. Ensure that all clearances to combustible materials are respected. Contact with the unit during operation may cause severe harm. Install a safety screen to keep children and pets away.
Figure 1: FUSION Firebox
Figure 2: Dimensions of FUSION Firebox
Figure 3: Dimensions of FUSION
Figure 4: Dimensions of FUSION with Circulating Chamber
2. COMPONENTS
2
2.1 Overall Dimensions
Figure 5: Combustion Air Control Levers
2.2 Combustion Air Control
3
Figure 6: Cold Hand Key
Figure 7: Secondary Air Control
Figure 8: Chimney Sweeping Cap
The Combustion Air Control is a patented mechanism (Patent No: US 7,325,541 B2) that regulates the air flow into the firebox based on the temperature of the unit. It is located on the top of the firebox, at the front center of the unit (see Figure 5). The combustion air control of the FUSION has two components: the Activator and the Burn Rate Selector. The left combustion control lever is the Activator. When starting a fire or adding a new load of wood, the Activator must be pushed in to allow a primary source of air to enter the firebox. The Activator will retract automatically with heat. The right combustion control lever is the Burn Rate Selector. The Burn Rate Selector can slide sideways to achieve different burn rates. When the Burn Rate Selector is positioned to the left, a maximum burn rate is achieved and when it is positioned to the right, a minimum burn rate is set.
WARNING: Never manipulate the Combustion Air Control with bare hands as it gets hot when the FUSION is in operation. Use the Cold Hand Key (see Section 2.3) to adjust the Combustion Air Control.
2.3 Cold Hand Key
The Cold Hand Key (Figure 6) is an accessory that comes standard with the FUSION insert. The Cold Hand Key is a tool used to manipulate the Combustion Air Control Levers (Figure 5) when it is hot.
2.4 Secondary Air Control
The Secondary Air Control (Figure 7) is a patent pending mechanism (Patent Pending No: GB1307428.1) that automatically regulates the amount of secondary air in accordance to the temperature of the FUSION to create a unique arrangement of natural and appealing flames that prolongs the combustion, increases the efficiency and reduces the emissions of the fireplace. The Secondary Air Control is factory set and requires no intervention from the user. The Secondary Air Control is located at the top of the firebox and releases secondary air through the perforations of the baffle of the FUSION.
2.5 Chimney Sweeping Cap
The chimney sweeping cap found at the baffle of the FUSION allows easy access for chimney sweeping without having to remove any components of the firebox (Figure 6).
WARNING: The chimney sweeping cap should be blocking the access to the chimney at all times during combustion. A chimney sweeping cap that is not blocking the baffle hole during combustion is a safety hazard, will overheat the fireplace and void the warranty.
Figure 10: Surround Size Options - Small, Medium, and Large (Left to Right)
2.6 Door
4
Figure 9: Removable Ash Lip
The FUSION wood burning insert comes with a Pyroceramic glass panel door. Pyroceramic is the highest grade available for fireplaces and stoves and can withstand temperatures up to 1300oF. To remove the door, open the door, lift it and pull it towards the bottom until the rod exits from the hinge holes.
NOTE: The door of the FUSION must remain closed at all times during operation.
2.7 Removable Ash Lip
The Ash Lip is a removable accessory that comes standard with the FUSION insert (Figure 7). It is installed on the door holder (under the two small angled tags below the door) and prevents ashes from falling onto the front of the hearth. The Ash Lip can be installed with the door open or closed. It is safe to operate the unit without the Ash Lip.
2.8 Blowers
The FUSION wood burning fireplace insert is equipped with two AC centrifugal compact fans on either side of the surround (electrical rating: 115V, 60Hz, and 19W).
CAUTION: Make certain that the fireplace in not in operation and the blowers are unplugged before accessing the electrical wiring.
Plug the power cord into an 115V grounded outlet for protection against a power surge. The blowers will turn on and turn off automatically during the operation of the unit. As the temperature of the fireplace insert increases and the heat activated sensor reaches 95°F, the fans will turn on. Note that the average time it takes for the fans to activate is between 30 to 45 minutes after starting a fire. The fans will turn off once the fireplace has cooled down and the heat activated sensor reaches 85°F. The speed of the fans can be adjusted with the variable speed control mounted on the wall. It is safe to operate the FUSION in the event of a power failure (fans not powered).
2.9 Surround
The FUSION wood burning insert is available in three different sizes. Refer to Figure 10 for the dimensions of the different surrounds available.
NOTE: SUPREME FIREPLACES INC. reserves the right to alter the dimensions of the surrounds without prior notice.
Figure 11: Adjustable Circulating Chamber
Figure 12: Adjustable Legs
Figure 13: Liner Adaptor
2.10 Adjustable Circulating Chamber
5
The adjustable circulating chamber (patent pending: GB1305647.8) is a standard component of the FUSION insert (Figure 11). It is designed to prevent heat escaping from the existing chimney and allows for an optimal flow and heat transfer. The width is adjustable from 32” to 38”, the front height is adjustable from 23” to 28” (with
the rear height fixed at the minimum 23”), and the hole for the
stainless steel liner is adjustable by 2” (front to rear).
NOTE: The circulating chamber requires minimal assembly. Please refer to Section 3.4 for detailed instructions.
2.11 Adjustable Legs
The FUSION insert is supplied with three adjustable legs (Figure 12) in the bottom of its firebox to allow adjustment of the height if the surround isn’t flushed with the wall of the masonry fireplace.
2.12 Liner Adaptor
The FUSION Liner Adaptor is a component that comes with the FUSION and is required to connect the stainless steel liner to the FUSION insert (Figure
13).
2.13 Metal Tag
The Metal Tag is found on the front sheet metal piece of the crate of the Fusion and indicates that alterations have been made to the masonry fireplace to accommodate the insert. The metal sheet piece having the Metal Tag is to be installed at the Bottom of the Circulating Chamber (see Section 3.3.1) using the provided screws. The Bottom of the Circulating Chamber should have the side with the Metal Tag installed face up so the Metal Tag is visible if the firebox were to be removed.
The Metal Tag reads as follows:
This fireplace has been altered to accommodate a fireplace insert and should be inspected by a qualified person prior to re-use as a conventional fireplace. Ce foyer a été modifié afin d'y insérer un foyer encastrable et doit être inspecté par une personne qualifiée avant sa réutilisation comme foyer conventionnel.
2.14 Serial Number
The serial number of the unit is located at the bottom of the removable Ash Lip (Refer to Section 2.7).