![](/html/42/420a/420ab7b4ec802ef7478bb65c0b5f02e41afe05d74a08d8deb62238f51457ad6e/bg1.png)
FACTORY-BUILT FIREPLACE MODEL
• SUPREME PLUS
Tested and certified by Intertek
• UL 127-1999
• ULC-S610-M87 R-94
OWNER’S MANUAL
- INSTALLATION
- OPERATION
Keep these instructions for future use.
Manufactured by:
3594 Jarry East, Montreal, QC., H1Z 2G4
Phone: 1-877-593-4722 Fax: (514) 593-4424
www.supremem.com
info@supremem.com
![](/html/42/420a/420ab7b4ec802ef7478bb65c0b5f02e41afe05d74a08d8deb62238f51457ad6e/bg2.png)
Model: Supreme Plus Revised, August 2008
SUPREME LIMITED LIFETIME WARRANTY
SUPREME FIREPLACES INC. warrants its factory-built fireplaces will be free from defects in material and workmanship,
under normal use and service, for a period of twenty-five (25) years from the date of purchase.
This warranty is only intended for the original retail purchaser, given that the product was purchased from SUPREME
FIREPLACES INC. or one of its distributors. This warranty is conditional upon correct installation and intended use of our
products and does not cover damages caused by misuse of the products. This warranty shall be void if the fireplace is not
installed by an authorized qualified technician in accordance with the installation instructions in the manual provided with
this product. The installation must meet local and national building codes.
WARRANTY LIMITATIONS:
1. During the first two years of the Limited Warranty, SUPREME FIREPLACES INC. will provide replacement
parts at no charge and will also pay for reasonable labor costs for repair work, except for the parts listed below.
EXCLUSIONS
SUPREME FIREPLACES INC. shall not be responsible for any labor cost for the following parts.
The following parts are guaranteed for two years: blowers, painted or plated parts, secondary air burning system.
The following parts are guaranteed for one year: door gasketing.
The following parts are guaranteed for 90 days: ceramic glass (Thermal Breakage only
2. During the third through the fifth year of the limited warranty, SUPREME FIREPLACES INC. will provide
replacement parts (if available) at no charge, except for the parts mentioned above. Supreme Fireplaces Inc. shall
not be responsible for any labor costs.
3. From the sixth through the twenty-fifth year of the limited lifetime warranty, SUPREME FIREPLACES INC. will
provide replacement parts (if available) at 50 % of the retail price, except for the parts mentioned above in
exclusions. SUPREME FIREPLACES INC. shall not be responsible for any labor costs.
Transportation and other related costs or expenses arising from the replacement or repair of defective parts will not be
covered by this warranty, nor will SUPREME FIREPLACES INC. assume responsibility for them.
This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, over
firing, abrasives, chemical cleaners, negligence are not covered by this warranty.
SUPREME FIREPLACES INC will not be responsible for environmental conditions such as inadequate vents or
ventilation, excessive venting configurations or negative air pressures which may or may not be caused by
mechanical systems such as exhaust fans, furnaces, clothes dryers, etc.
The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the
defect. The manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the
wholesale price of the defective part(s).
The manufacturer shall in no event be responsible for any consequential damages of any nature, which are in excess of the
original purchase price of the product.
Any complete fireplace, or part thereof, that is replaced or serviced under this warranty will be warranted for a period not
exceeding the remaining term of the original warranty.
This limited Lifetime warranty is effective on all appliances sold and supersedes any and all warranties currently
in existence.
).
2
![](/html/42/420a/420ab7b4ec802ef7478bb65c0b5f02e41afe05d74a08d8deb62238f51457ad6e/bg3.png)
Model: Supreme Plus Revised, August 2008
INSTALLATION INSTRUCTIONS
Note: Authority having jurisdiction (such as the municipal building department, the fire department, the fire prevention
bureau, etc) must be consulted before installation to determine if a building permit is required.
CAUTION: Read these instructions carefully before commencing the installation. Failure to follow these
instructions may result in property damage, bodily harm and even death.
Note: Do not install a fireplace insert inside the factory-built fireplace, unless the insert has been tested and is
SPECIFICALLY CERTIFIED for use in conjunction with these models.
WARNING: As this fireplace is only intended for burning wood, do not install an unvented gas log set into the
structure.
LOCATION OF THE FIREPLACE
Select the appropriate location for the fireplace. The position of the fireplace should be selected on the basis of heat output,
safety and esthetics.
The cutting of joists and rafters for floor, ceiling and roof chimney penetrations will affect the load bearing capacities of the
dwelling structure. Improper cutting of chimney openings in the attic and roof will affect the bearing and thermal
insulating capacity as well as the weather tightness of the dwelling. Incorrect workmanship must be avoided.
Consult a professional engineer or a certified installer as required.
If possible, select a location for the fireplace that will minimize the number of offsets in the chimney course. Offsets will
reduce the draft, complicate the chimney sweeper’s work and increase installation costs.
An installation drawing should be prepared prior to the installation work.
FIREPLACE INSTALLATION
The fireplace can be placed directly onto or against normal, combustible construction materials such as lumber, plywood,
millboard, particleboard, drywall and decorative wood paneling.
The fireplace should NOT be placed directly against, or be in contact with an insulation material.
The framing around the face of the fireplace should be constructed with nominal 2" x 4" construction lumber or metal studs.
The framing is must be nailed or screwed onto a podium and to the ceiling. As there are some differences between the
podium requirements in Canada and in the US, it is very important to consider in which country the installation will be
made. The Figure 1 shows the minimum framing dimensions for US and Canada.
DO NOT NAIL OR SCREW FRAMING MEMBERS INTO THE FIREPLACE.
Position the fireplace at the selected location, taking care of respecting the minimum clearances to combustible materials
shown in Figure 2.
The minimum dimensions of the hearth extension are specified in Figure 2. The hearth extension is to be covered with noncombustible materials only, such as steel, cement or mortar, stone, brick, ceramic tiles. The ceramic tiles must have a
minimum thickness of 5/16’’ or an equivalent thickness of the other materials. Unidentified materials may be combustible:
verify the product specifications prior to installation.
3
![](/html/42/420a/420ab7b4ec802ef7478bb65c0b5f02e41afe05d74a08d8deb62238f51457ad6e/bg4.png)
Model: Supreme Plus Revised, August 2008
Figure 1
Make sure to seal the gap between the fireplace face and the hearth extension with a metal strip or a sand-cement grout in
order to prevent sparks or embers from reaching combustible materials.
4
![](/html/42/420a/420ab7b4ec802ef7478bb65c0b5f02e41afe05d74a08d8deb62238f51457ad6e/bg5.png)
Model: Supreme Plus Revised, August 2008
CLEARANCES TO COMBUSTIBLES
WARNING: The hearth extension has to be installed only as illustrated.
CLEARANCE TO THE FRONT OF THE FIREPLACE
The minimum distance between the front of the fireplace and any combustible material is 5 feet, (152 cm).
Do not place such materials within this minimum distance in order to reduce risk of fire.
Figure 2
5